The Artemis Plug-in Improves the Accuracy of the Power System Under PSB/ARTEMIS/RT-LAB
Publication date : May 2001
Paper File :
artemis_vs_tustin.pdf
Share this document:
Author(s)
Nicolas Léchevin, Jean Bélanger, Guillaume Murere,Abstract
This application note reports how the TUSTIN method in PSB and the ART5 method in the ARTEMIS Add-On compare in terms of precision, particularly for long-term simulation. The ARTEMIS Add-On uses the ART5 method and the ‘Zero hold for input’ option is not checked.
Related Products
ARTEMiSeMEGAsim PowerGrid Real-Time Digital Hardware in the Loop Simulator
RT-LAB Professional