> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e00-conditioning-modules-general-information/modules-handling.md).

# Modules Handling

## Form factor <a href="#form-factor-inlineextension" id="form-factor-inlineextension"></a>

The **OP8E00** series of mezzanine modules follows **OPAL-RT's Type-E form factor**.

* The modules are rectangular. Their L x W dimensions are 14.6 x 4.4 cm (5.75 in x 1.73 in)
* Two Sullins SBH11 20pos Male connectors are located on the bottom side of the module's PCB. The connectors are labeled either P2/P3:
  * connector P2 carries signals to/from the simulator
  * connector P3 carries signals to/from the unit under test
* Another connector P1 (3M N2520-6002-RB 20pos ) is used to supply power to the module
* Two mounting holes allow affixing the module onto the carrier.

{% hint style="info" %}
&#x20;Not all the carriers have both mounting holes.
{% endhint %}

*The components installed and the color of the PCB may differ.*

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FlDAS01VZUYbEJAT0MASL%2Fimage.png?alt=media&amp;token=e620b8ec-6840-4416-bb16-35581cea5fc7" alt=""><figcaption><p><em>OP8E00 Top view</em></p></figcaption></figure>

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FMPOZj3jWmTCyiDxjDzEf%2Fimage.png?alt=media&amp;token=2fba96fd-91eb-4947-9bf5-e894d3fe92f1" alt="" width="563"><figcaption><p><em>OP8E00 Bottom View</em></p></figcaption></figure>

## Installation <a href="#installation" id="installation"></a>

### Carrier board <a href="#inlineextension-carrier-board" id="inlineextension-carrier-board"></a>

OP8E00 modules come pre-installed on a carrier board which is installed either in an I/O expansion chassis (e.g. OP7000), a conditioning chassis (OP8300, OP8681) or a mapping box as illustrated in the examples below.

Since the OP8E00 modules are used to condition signals coming from or going to the simulator, the direction (input or output) of the signals of all modules installed on the carrier must match the direction of the conversion module to which they are linked in the conditioning chain. It is possible to mix modules with different characteristics on the same carrier, provided the direction of all modules is the same.

| Type of system            | Schematic overview                                                                                                                                                                                                                                       | Carrier P/N |
| ------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ----------- |
| **OP7000 or OP7000V2**    | <img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FXEQp9W8E5lw8SJBhrcwY%2Fimage.png?alt=media&amp;token=d4bdca92-9aa0-4902-9e96-3cd2fb788686" alt="" data-size="original"> | 126-0417    |
| **OP8300 or Mapping box** | <img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FyPKkt0WL5bLBW8X97dsx%2Fimage.png?alt=media&amp;token=98a0cf54-414b-496b-9ffd-947dae1d876f" alt="" data-size="original"> | 126-0446    |
| **OP8681**                | <img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FleyMUrty5lswp9M2NkjU%2Fimage.png?alt=media&amp;token=39e84c73-2317-483b-936d-2570a32118c2" alt="" data-size="original"> | 126-0478    |

### Adding or replacing a module <a href="#adding-or-replacing-a-module" id="adding-or-replacing-a-module"></a>

Follow these instructions to install a new module or to replace a defective module.

{% hint style="danger" %}
Should servicing be necessary due to a defective board or for configuration changes to the system, authorization must be requested from OPAL-RT before opening the system.\
Opening the unit without approval renders the warranty null and void.

The module must be installed on the carrier board using great care. \
Use an electrostatic bracelet when manipulating the module.

The module can only be used with OPAL-RT’s carrier boards.
{% endhint %}

1. Open the chassis following the procedure provided by OPAL-RT when authorization for servicing was granted.
2. Locate the carrier board, and locate the slot on the carrier where the module should be installed or replaced. Refer to the user manual of the system to identify the slots.
3. Module removal
   * Gently pull the module vertically out of the carrier board's connectors. Avoid bending the module.
4. Module installation&#x20;
   * Turn the module in the proper direction so that its polarized connectors align with the carrier board connectors,
   * Apply light pressure vertically to push the module into the carrier board. When the module is installed, only the top of the circuit board is visible.
   * Secure the connection by using screws to affix the module to the carrier board using the mounting holes available on the carrier.

## Connection <a href="#connection" id="connection"></a>

Since the modules are located inside the I/O expansion or conditioning chassis, their signals are not accessed by the user directly, but through dedicated DB37-F connectors made available at the front or back face of the chassis. The module signals are routed to these connectors via the carrier board of the system.

{% hint style="info" %}
Refer to the User Manual of your system to identify how the modules are mapped to the chassis's DB37-F connectors.
{% endhint %}

Each DB37-F connector typically provides connection points for 16 channels., hence up to four modules share the same DB37-F connector.

The pin assignment of the DB37-F connector varies depending on the modules installed on the carrier board.

{% hint style="danger" %}
To prevent damage, make sure to refer to the pin assignment of each specific module installed in your system before connecting the signals.
{% endhint %}

## Calibration <a href="#calibration" id="calibration"></a>

Due to the nature of the electronic circuitry they use, the analog-to-digital and digital-to-analog modules are subject to a slight dispersion of the values they output or measure, as compared to the theoretical values.

Since the modules do not hold an on-board memory for storing factory calibration values, calibration must be performed in-situ and correction parameters (offset and gain) must be introduced in the model used for the real-time simulation.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e00-conditioning-modules-general-information/modules-handling.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.