> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e02-current-input-module.md).

# OP8E02 Current Input Module

The **OP8E02** module converts four (4) current input signals into ±16V voltage signals that can be measured with an OP5340 Analog input module.

The channels are individually configurable for one of the following ranges : 4-20mA, ±25mA, ±50mA, ±75mA, and ±100mA, allowing greater accuracy.

## Features <a href="#features" id="features"></a>

* Type-E module
* Converts 4 current input signals into ±16V voltage signals
* Configurable for five different ranges: 4-20 mA, ±25mA, ±50mA, ±75mA, and ±100mA
* Input range individually configurable via dip-switches

## Board layout <a href="#board-layout" id="board-layout"></a>

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FP2CXLNoayUns9dYBA3Iu%2Fimage.png?alt=media&amp;token=2bd053a6-70a0-49a6-87fd-5d0e73cb386e" alt=""><figcaption><p><strong>OP8E02 - Top View</strong></p></figcaption></figure>

## Channel description <a href="#channel-description" id="channel-description"></a>

The current is converted to voltage using the voltage reading at the terminal when the current to measure flows through the resistor.

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FVRbBX1kIaw9jke767xkH%2Fimage.png?alt=media&amp;token=76269939-e2b2-4ae9-a215-1c3a28030f33" alt="" width="362"><figcaption></figcaption></figure>

$$
Vout=Iin\*R
$$

Depending on the maximum current value expected, a DIP switch lets you select the resistor required to adjust the output voltage, in order to reach the maximum range (±16V) that can be measured by the OP5340.

For example, if the module is set for ±100mA (158.5 ohms) mode and the signal to measure is only ±25mA, the module output will be a maximum of ±3.9V. Choosing the ±25mA mode to ensure that the output range will be ±15.85V, which yields a better resolution.

It may not be possible to reach the desired range, depending on the compliance voltage supplied by the current source. For example, if the current is 20mA and the source supplies is only 5V, the maximum reading will never be reached if the module is in the ±25mA mode,

since 20mA in 634 ohms would require a voltage of 12V, which the source cannot supply. It is therefore necessary in that case to select the 4-20mA mode.

The table below gives the resistance and compliance voltage for each mode:

| MODE       | RESISTOR EQUIVALENT | COMPLIANCE VOLTAGE REQUIRED |
| ---------- | ------------------- | --------------------------- |
| **mA**     | **OHMS**            | **VOLT**                    |
| **4-20mA** | 249                 | 4.98                        |
| **25mA**   | 634                 | 15.85                       |
| **50mA**   | 317                 | 15.85                       |
| **75mA**   | 211.33              | 15.84975                    |
| **100mA**  | 158.5               | 15.85                       |

## DIP switch settings <a href="#dip-switch-settings" id="dip-switch-settings"></a>

The DIP switches are accessible on the top of the module:

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FX7Uh3Tle450zYvEdqAXk%2Fimage.png?alt=media&amp;token=4acc6961-44be-4e35-b666-7ea6acd685d8" alt=""><figcaption></figcaption></figure>

<table data-search="false"><thead><tr><th>Voltage</th><th>Switch Positions</th><th>Switch Positions</th><th>Switch Positions</th><th>Switch Positions</th><th>Switch Positions</th></tr></thead><tbody><tr><td></td><td><strong>Switch 1</strong></td><td><strong>Switch 2</strong></td><td><strong>Switch 3</strong></td><td><strong>Switch 4</strong></td><td><strong>Switch 5</strong></td></tr><tr><td><strong>±25 mA</strong></td><td>On</td><td>Off</td><td>Off</td><td>Off</td><td>Off</td></tr><tr><td><strong>±50 mA</strong></td><td>On</td><td>On</td><td>Off</td><td>Off</td><td>Off</td></tr><tr><td><strong>±75 mA</strong></td><td>On</td><td>On</td><td>On</td><td>Off</td><td>Off</td></tr><tr><td><strong>±100 mA</strong></td><td>On</td><td>On</td><td>On</td><td>On</td><td>Off</td></tr><tr><td><strong>Follower</strong></td><td>Off</td><td>Off</td><td>Off</td><td>Off</td><td>Off</td></tr><tr><td><strong>4-20 mA</strong></td><td>Off</td><td>Off</td><td>Off</td><td>Off</td><td>On</td></tr></tbody></table>

{% hint style="info" %}
When the switch is in Follower mode, it acts as a simple throughput (voltage to voltage), rather than conversion mode (current to voltage).
{% endhint %}

## Pin Assignment <a href="#pin-assignment" id="pin-assignment"></a>

Refer to the [OP8E00 Modules Pin Assignment](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e00-conditioning-modules-general-information/modules-pin-assignment.md) table.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e02-current-input-module.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.