> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e03-current-output-module.md).

# OP8E03 Current Output Module

The **OP8E03** module converts four (4) output signals produced by an OP5330 Analog Output mezzanine module into four  (4) current sources.

Each channel can be adjusted individually to convert ±16V voltages into either ±25mA or ±50mA current values.

## Features <a href="#op8e03description-features" id="op8e03description-features"></a>

* Type-E module
* Converts four ±16V voltage signals into ±25mA or ±50mA current sources
* Input range individually configurable via switches

## Board Layout <a href="#op8e03description-boardlayout" id="op8e03description-boardlayout"></a>

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FQDMYxNbVVgJz1fU2E1eL%2Fimage.png?alt=media&amp;token=6748e189-a36e-4211-abd6-a8fe04afe2c9" alt=""><figcaption><p><strong>OP8E03 - Top View</strong></p></figcaption></figure>

## Channel description <a href="#op8e03description-channeldescription" id="op8e03description-channeldescription"></a>

### Gain <a href="#op8e03description-gain" id="op8e03description-gain"></a>

* ± 1V (from OP5330) = ±1.716mA for 25mA range.
* ± 1V (from OP5330) = ±3.383mA for 50mA range.

### Switch settings <a href="#op8e03description-switchsettings" id="op8e03description-switchsettings"></a>

The four switches are located on the top of the module They allow setting each channel to either the ±25mA or ±50mA output range:

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FKraFvDEW9f3ZzxO33RFV%2Fimage.png?alt=media&amp;token=8f6739fd-072f-4212-af48-43fa49a4f060" alt="" width="563"><figcaption></figcaption></figure>

## Pin assignment <a href="#op8e03description-pinassignment" id="op8e03description-pinassignment"></a>

Refer to the [OP8E00 Modules Pin Assignment](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e00-conditioning-modules-general-information/modules-pin-assignment.md) table

{% hint style="info" %}
Current outputs can be merged at the DB37 outputs to achieve a higher current range ( ex 2\*50mA, or 4\*25mA).
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e03-current-output-module.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.