> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e51-dry-contact-relay-module.md).

# OP8E51 Dry-contact Relay Module

The **OP8E51** module is designed to be connected to digital output signals coming from an OPAL-RT simulator in order to control 4 dry-contact relays.

## Features <a href="#features" id="features"></a>

* 4 channels
* Relay output  (normally open or normally closed.) individually selectable via jumpers
* Input command from 5V to 30V to energize the relay.

## Board layout <a href="#board-layout" id="board-layout"></a>

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2FtYuV7eFZkyeaBPHrMFv3%2Fimage.png?alt=media&amp;token=9a45cc96-39d0-449d-afcd-572085ee61db" alt=""><figcaption><p><strong>OP8E51 - Top View</strong></p></figcaption></figure>

## Channel description <a href="#channel-description" id="channel-description"></a>

Each channel holds a dry-contact relay that get activated by an output signal coming from the simulator. The voltage range of this signal is 5-30V.

The default relay setting is Normally Closed (N.C.). Jumpers on the board allow changing the relay setting to Normally Open (N.O.)

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2Fzc4nVCcZBcxQjN3xljZY%2Fimage.png?alt=media&amp;token=0a0a4ac5-e0e9-4227-9bcc-52ed078c071b" alt=""><figcaption></figcaption></figure>

### Typical application diagram <a href="#typical-application-diagram" id="typical-application-diagram"></a>

<figure><img src="https://609051844-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FGba4ytXQss1VNonuRAzM%2Fuploads%2F3EyRc4xzr90lBMsLhxLI%2Fimage.png?alt=media&amp;token=eaac9911-d909-4010-adc6-e067ae908814" alt=""><figcaption></figcaption></figure>

## Pin assignment <a href="#pin-assignment" id="pin-assignment"></a>

Refer to the [OP8E00 Modules Pin Assignment](https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e00-conditioning-modules-general-information/modules-pin-assignment.md) table.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/accessories-conditioning-modules/i-o-conditioning-modules/op8e51-dry-contact-relay-module.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.