> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/cmde-add-on/model-and-simulation/simulate-a-battery-cell-model.md).

# Simulate a Battery Cell Model

## Introduction

Simulating battery cells enables engineers to test and validate Battery Management System (BMS) algorithms without relying on physical hardware. This approach ensures that critical functions—such as communication, safety mechanisms, cell balancing, and fault detection—operate as intended. In addition, simulation allows researchers to evaluate a wide range of battery chemistries without the need to physically build each variation, significantly accelerating the identification of optimal materials and configurations.

VeriStand provides a comprehensive framework for implementing this workflow. It allows users to develop battery cell models, integrate them into the VeriStand System Definition, map model inputs and outputs to the corresponding emulated device channels, and execute the complete system. In this setup, the battery cell models run on the CPU of the real-time target, while the cell monitoring device is emulated on the FPGA

## Configure the project <a href="#project-configuration" id="project-configuration"></a>

{% stepper %}
{% step %}

### Add external model

Create a model of the external circuit and add it to the VeriStand project. Refer to [**Integrating and Executing Models**](https://www.ni.com/docs/en-US/bundle/veristand/page/integrate-execute-models.html) for detailed instructions. MathWorks Simulink is commonly used.

1. **Determine the number of cells** to be simulated.
2. **Identify the data exchanged** between each cell and its corresponding cell monitoring device. Refer to the device documentation for a complete list of supported data channels.
3. **Develop the cell model(s)** using your preferred modeling environment. While there are no standard battery cell models, environments such as **Simulink** provide many of the necessary building blocks.
4. **Define model inputs and outputs** to enable data exchange with the emulated cell monitoring devices. These inputs and outputs will later be mapped to device channels in VeriStand.
5. **Compile the model(s) for the Linux target.**&#x20;
6. **Add the compiled model(s) to the VeriStand project.** Refer to [Adding and Configuring a Model ](https://www.ni.com/docs/en-US/bundle/veristand/page/add-configure-model.html)for step-by-step instructions.

{% hint style="info" %}
It is recommended to keep the default **Simulation model processor** setting (*Automatic*) so that VeriStand assigns the CPU on which the model will run. Manual CPU assignment is not necessary in most cases.

Applications involving a **large number of simulated cells** may require distributing the cells across multiple models to optimize CPU performance. Ensure that cells communicating with the same cell monitoring device are grouped within the same model.

Achieving optimal CPU performance may require iterative adjustments; some trial and error should be expected. Contact OPAL-RT Support if additional assistance is needed.
{% endhint %}
{% endstep %}

{% step %}

### Map signals <a href="#map-signals" id="map-signals"></a>

In the VeriStand Editor, connect the signals between the external cell models and the cell monitoring devices:

<figure><img src="https://2869406741-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fgtd2gZ5PvjsRaV45Czvu%2Fuploads%2FmTJartkaAHdrubEwQ1Jn%2Fimage.png?alt=media&amp;token=3e31d1ae-4e89-4cef-a233-48acc11c3329" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}

### Create User Interface

Data mapped to the input and output channels of each emulated cell monitoring device can originate either from a CPU model or from a VeriStand screen. In some cases, certain channel values do not need to be driven by a cell model. These channels can instead be mapped to the user interface, allowing users to monitor and adjust values during project execution
{% endstep %}
{% endstepper %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/cmde-add-on/model-and-simulation/simulate-a-battery-cell-model.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.