> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/panels-overview.md).

# Panels Overview

The **Asynchronous Machine** model file, located in the folder **OP1160 - Electric Machines Courseware,** is **EM\_Asynchronous-version.zip**

The simulator panel provides the test bench’s interactive interface, which includes access to settings, measurement device display and protection system status.\
It allows users to manually control the bench, to start it and to regulate group speed by manipulating power, connecting various devices to the induction machine rotor, decoupling machine shafts to block the rotor or to reset the protection system in the event of a fault.\
This section provides the complete reference for features located on the simulator panel.

## Startup Panel <a href="#id-3.1-startup-panel" id="id-3.1-startup-panel"></a>

The main panel is shown in Fig. 3 at simulator startup.\
Default setting values shown in Fig. 3 are applied, and control switches are grey, which means disabled.\
Machines are stopped, all power output voltages are at 0 V.\
The simulator is functioning, and the test bench can be used according to user needs, while maintaining the safe settings and making sure not to trip the protection system.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FjrBlHmQZjJhCMJQiPzfv%2Fe6d22428-07c8-418d-939f-eba1bdcb359d.jpg?alt=media&amp;token=5ac246c8-e186-4654-b46f-bc0b7619d0cd" alt=""><figcaption><p><strong>Figure 3</strong>: Panel at simulator startup</p></figcaption></figure>

Observe, from left to right, in Fig 3, how the various settings and measurement display options are grouped according to the **virtual test bench components**.

* **DC machine**: power settings, measurement display and protection status (fuses).
* **Shaft**: for the detachable mechanical coupling of the shaft that connects the machines, displays torque and speed data.
* **Asynchronous Machine:** electrical panel with fields to modify values, switches to control rotor winding connections and a rotary switch to modify external rotor resistances, measurement and protection (fuse) status displays.
* **Stator connections:** command switches to activate or deactivate the induction machine’s stator connection with several devices.
* **AC Grid/Inverter/Measurement Resistors**: three tabs that provide access to connect external devices to the induction machine’s stator (see Section 3.3).\
  **AC Grid** provides controls for an autotransformer connected to an infinite bus; **Inverter** provides controls for a battery powered, variable voltage and frequency PWM inverter, and **Measurement Resistors** provides measurements for the stator windings resistances.
* **Protections:** protection system control panel allows users to simulate a fuse reset (Reset) in the event of a fault.

{% hint style="info" %}
*Blowing one fuse can cause machines to stop according to the dynamics of turning parts caused by inertia and friction.*\
*Just like with a real test bench, the user must determine the causes of the fault before restoring power and resetting switches to ensure safe restart.*\
*Failure to do so will result in triggering the protection system again, as would happen with a real test bench!*
{% endhint %}

The tabs in the bottom panel of the screen of Fig.3 display the oscilloscopes connected to the bench.

### Parameters setup and control switches <a href="#id-3.2-tables-for-parameters-setup-and-control-switches" id="id-3.2-tables-for-parameters-setup-and-control-switches"></a>

#### User accessible setup parameters

<table data-search="false"><thead><tr><th>Parameter setting</th><th>Default value</th><th>Variation range</th></tr></thead><tbody><tr><td><strong>SC1: Va DC Machine armature (Volt)</strong></td><td>0</td><td>[0 ; 500] V</td></tr><tr><td><strong>SC2: Vf DC Machine field (Volt)</strong></td><td>0</td><td>[0 ; 500] V</td></tr><tr><td><strong>SC3: Vdc external supply (Volt)</strong></td><td>0</td><td>[0 ; 50] V</td></tr><tr><td><strong>SA1: Autotransformer (Volt)</strong></td><td>0</td><td>[0 ; 500] V</td></tr><tr><td><strong>fs (Hz) AC grid frequency</strong></td><td>60 Hz</td><td>[1 ; 100] Hz</td></tr><tr><td><strong>Resistor value (Ω)</strong></td><td>1.5 Ω</td><td>1.5 ; 2.5 Ω</td></tr><tr><td><strong>Inverter frequency</strong> <strong>(Hz)</strong></td><td>0</td><td>[1 ; 90] Hz</td></tr></tbody></table>

{% hint style="info" %}
Users can make precise adjustments using the controls to the right of the field.
{% endhint %}

#### Command switches and LED fuse status indicators

<table data-search="false"><thead><tr><th width="160.199951171875">Command Switches</th><th width="100.20001220703125">Icon</th><th>Description</th></tr></thead><tbody><tr><td><strong>K1: AC Grid</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt=""></td><td>The grid is not connected to the induction machine's stator.<br>Switch (<mark style="color:$danger;"><strong>K1</strong></mark>) is open.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>The grid is connected to the induction machine's stator.<br>Switch (<mark style="color:$danger;"><strong>K1</strong></mark>) is closed</td></tr><tr><td><strong>K2: Inverter</strong> </td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt=""></td><td>The inverter is not connected to the induction machine's stator.<br>Switch (<mark style="color:$danger;"><strong>K2</strong></mark>) is open.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>The inverter is connected to the induction machine's stator.<br>Switch (<mark style="color:$danger;"><strong>K2</strong></mark>) is closed.</td></tr><tr><td><strong>K3: Measurement Resistors</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>The DC voltage source SC3 is not connected to the machine's stator.<br>Switch (<mark style="color:$danger;"><strong>K3</strong></mark>) is open<em>.</em></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>The DC voltage source SC3 is connected to the induction machine's stator. Switch (<mark style="color:$danger;">K3</mark>) is closed.</td></tr><tr><td><strong>K4: Open Rotor</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>The induction machine's windings are short-circuited.<br>Switch (<mark style="color:$danger;"><strong>K4</strong></mark>) is closed.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>The synchronous machine's rotor windings are in open circuit.<br>Switch (<mark style="color:$danger;"><strong>K4</strong></mark>) is open.</td></tr><tr><td><strong>K5: Rotor Resistor</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>There is no external resistor connected to the induction machine's rotor.<br>Switch (<mark style="color:$danger;"><strong>K5</strong></mark>) is open.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>External resistor, adjustable via dial on the induction machine's panel, are serially connected to the induction machine's rotor. Switch (<mark style="color:$danger;"><strong>K5</strong></mark>) is closed.</td></tr><tr><td><strong>K6: Decouple Shafts</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>The shaft of the induction machine is driven by the shaft of the DC machine</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>The shaft of the induction machine is decoupled from the shaft of the DC machine</td></tr><tr><td><strong>K7: Phase inversion</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>The AC grid's phase sequence is positive.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>The AC grid's phase sequence is negative (reverse).</td></tr><tr><td><strong>K8: Reset</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>Reset push-button is inactive.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>Reset push-button is active and simulates a fuse replacement after a fault.</td></tr><tr><td><strong>K10: Trig-Stator</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>Waveforms are not triggered, and signals are moving. The Oscilloscope1 group trigger is disabled.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>Waveforms are triggered. The stator voltage is acting as the reference signal.</td></tr><tr><td><strong>K11: Trig-Rotor</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlqjJHVGamIytSPQN1Qb3%2Fimage.png?alt=media&amp;token=3f4aea6c-2f11-4bb7-84a2-efb15979563a" alt="" data-size="original"></td><td>Waveforms are not triggered, and signals are moving. The Oscilloscope1 group trigger is disabled.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FDOzt0GbdfY14L1rnuZO8%2Fimage.png?alt=media&amp;token=5d794768-584d-46ab-974b-23356c80637f" alt=""></td><td>Waveforms are triggered. The rotor voltage Is acting as the reference signal.</td></tr></tbody></table>

<table><thead><tr><th width="89.99993896484375">Fuses</th><th>LED indicators</th></tr></thead><tbody><tr><td><p><strong>Fia</strong></p><p><strong>Fia</strong></p></td><td><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F35XOXR2dPJbnTuuOJKu8%2Fimage.png?alt=media&amp;token=ddf7cbf8-f679-4ce0-8da0-bf5de2ed6163" alt="" data-size="original">The DC machine's armature fuse is blown.</p><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FRY8ltbQmFssx0XgzKJK5%2Fimage.png?alt=media&amp;token=49a3c5c8-4758-4cfb-a410-a58ce9f9c37a" alt="">The DC machine's armature fuse is intact.</p></td></tr><tr><td><p><strong>Fif</strong></p><p><strong>Fif</strong></p></td><td><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FnfyxfnQ6a6LJ7GQlW0u6%2Fimage.png?alt=media&amp;token=fe3e8b9e-7905-4c75-8f68-17a462e284a4" alt="" data-size="original">The DC machine's field fuse is blown.</p><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FgupZXOUxoGLbvfzi7AB4%2Fimage.png?alt=media&amp;token=fae84483-90e2-420e-a42b-1f47e248a372" alt="">The DC machine's field fuse is intact.</p></td></tr><tr><td><p><strong>Fi1</strong></p><p><strong>Fi1</strong></p></td><td><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FKeepqrZRFPK6sSg7zeZR%2Fimage.png?alt=media&amp;token=7d80469d-5bef-4fc2-9ddb-a8f183f945bb" alt="" data-size="original">The induction machine's stator phase 1 fuse is blown.</p><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FSx7vueaXb9llf55u6GQy%2Fimage.png?alt=media&amp;token=45a14639-e3cb-454a-a777-6fe57fcd97e4" alt="">The induction machine's stator phase 1 fuse is intact.</p></td></tr><tr><td><p><strong>Fi2</strong></p><p><strong>Fi2</strong></p></td><td><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F74egbjDDMjRbrCDxLir7%2Fimage.png?alt=media&amp;token=4510c1ea-95ca-4e92-9fad-e6e2b4f11593" alt="" data-size="original">The induction machine's stator phase 2 fuse is blown.</p><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fq2qLSZ0cDjrg75hDF8ek%2Fimage.png?alt=media&amp;token=5ffde44a-62da-4923-b0fb-7594638adf92" alt="">The induction machine's stator phase 2 fuse is intact.</p></td></tr><tr><td><p><strong>Fi3</strong></p><p><strong>Fi3</strong></p></td><td><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FlmmaWoJQ8Z0iECDbGD2z%2Fimage.png?alt=media&amp;token=eb6f005d-d2d8-4c83-b400-3b1a94794dc0" alt="" data-size="original">The induction machine's stator phase 3 fuse is blown.</p><p><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FiQFU1KWbmUSDYMh3WRMy%2Fimage.png?alt=media&amp;token=bf0d85e9-2e46-4250-907a-773faa11fcf0" alt="">The induction machine's stator phase 3 fuse is intact.</p></td></tr></tbody></table>

### Tabs description <a href="#id-3.3-tabs-description" id="id-3.3-tabs-description"></a>

The simulator interface, shown in Fig.3 contains several additional tabs selectable by the user:

* **Electrical panel** for devices that can be connected to the induction machine's stator: “AC Grid”, “Inverter” and “Measurement Resistors”. The user can select devices according to the desired test.
* **“Help" tab**: in the upper left Section of the interface, the "Help" tab contains information of the basic tests and their associated wiring diagrams.

## Measurement device display and oscilloscope waveforms <a href="#id-3.4-measurement-device-display-and-oscilloscope-waveforms" id="id-3.4-measurement-device-display-and-oscilloscope-waveforms"></a>

Device display modules shown in the main screen of the virtual simulator are shown in Fig.3. The sign convention by devise is also provided.

#### Display modules for measurement devices and sign convention for parameters displayed

#### DC Machine

<table><thead><tr><th width="98.20001220703125">Display</th><th width="87.39996337890625">Label</th><th>Displays Content</th></tr></thead><tbody><tr><td>Display<sub>1</sub></td><td>V<sub>a</sub></td><td>Voltage at machine armature terminals.</td></tr><tr><td>Display<sub>2</sub></td><td>I<sub>a</sub></td><td>Current in the armature (positive for operation in a generator rotating in N positive direction).<br>The power label convention V<sub>a</sub>. I<sub>a</sub> is generator-type: V<sub>a</sub>. I<sub>a</sub> is positive in generator operation and negative in motor operation.</td></tr><tr><td>Display<sub>3</sub></td><td>V<sub>f</sub></td><td>Voltage at field terminal.</td></tr><tr><td>Display<sub>4</sub></td><td>I<sub>f</sub></td><td>Current in the field.</td></tr></tbody></table>

#### Shaft

<table><thead><tr><th width="97.20001220703125">Display</th><th width="89.7999267578125">Label</th><th>Displays Content</th></tr></thead><tbody><tr><td>Display<sub>1</sub></td><td>N</td><td>Drive rotation speed [rpm] (according to convention N is positive when the phase voltage sequences applied to the induction motor stator is direct)</td></tr><tr><td>Display<sub>2</sub></td><td>T<sub>u</sub></td><td>DC machine resistive torque (according to convention, it is positive when operating in a generator rotating in N positive direction).</td></tr></tbody></table>

#### Asynchronous Machine

<table><thead><tr><th width="98.5999755859375">Display</th><th width="88.20001220703125">Label</th><th>Displays Content</th></tr></thead><tbody><tr><td>Display<sub>1</sub></td><td>U<sub>s</sub></td><td>RMS line-line voltage at stator terminals.</td></tr><tr><td>Display<sub>2</sub></td><td>I<sub>s</sub></td><td>RMS line current in stator.</td></tr><tr><td>Display<sub>5</sub></td><td>P</td><td>Induction machine active power. The sign convention is receptor-type: P is positive in motor mode operation.</td></tr><tr><td>Display<sub>6</sub></td><td>Q</td><td>Induction machine reactive power. The sign convention is receptor-type: Q is positive if it is absorbed by the induction machine.</td></tr></tbody></table>

#### AC Grid

<table><thead><tr><th width="99.20001220703125">Display</th><th width="83.39996337890625">Label</th><th>Displays Content</th></tr></thead><tbody><tr><td>Display<sub>1</sub></td><td>U</td><td>RMS line-line voltage at the autotransformer’s SA1 output.</td></tr><tr><td>Display<sub>2</sub></td><td>I</td><td>RMS line current at the autotransformer’s SA1 output.</td></tr></tbody></table>

#### Inverter

<table><thead><tr><th width="102.39996337890625">Display</th><th width="91.39996337890625">Label</th><th>Displays Content</th></tr></thead><tbody><tr><td>Display<sub>1</sub></td><td>V<sub>s</sub>/f<sub>s</sub></td><td>Ratio between Vs/fs and [V/Hz].</td></tr><tr><td>Display<sub>2</sub></td><td>I<sub>bat</sub></td><td>Mean current supplied by the battery to the inverter [A]. According to convention, it is positive when the inverter supplies active power to the induction motor.</td></tr></tbody></table>

#### Measurement Resistors

<table><thead><tr><th width="99.60003662109375">Display</th><th width="86.60003662109375">Label</th><th>Displays Content</th></tr></thead><tbody><tr><td>Display<sub>1</sub></td><td>U<sub>dc</sub></td><td>DC current between two induction machine stator terminals to measure resistances.</td></tr><tr><td>Display<sub>2</sub></td><td>I<sub>dc</sub></td><td>DC current flowing through the stator during resistance measurement.</td></tr></tbody></table>

{% hint style="info" %}
All physical measurements listed in **Table 5** are represented in test setup schematics.
{% endhint %}

Waveforms for electrical and mechanical signals displayed on the oscilloscopes are listed in Table 6.\
Each oscilloscope allows users to view one or two signals.\
Voltage and/or current range settings and time settings are also provided in this table.

### Waveforms displayed and oscilloscope settings

<table><thead><tr><th width="318.79998779296875">Oscilloscopes</th><th>Waveforms displayed</th></tr></thead><tbody><tr><td>Oscilloscope 1</td><td><p>Induction machine stator line-line voltages [U<sub>s</sub>].</p><p>Induction machine rotor line-line voltages [U<sub>r</sub>].</p></td></tr><tr><td>Oscilloscope 2</td><td>Induction machine stator currents [Is].</td></tr><tr><td>Y axis scale 1</td><td>Oscilloscope1 voltage range settings.</td></tr><tr><td>Y axis scale 2</td><td>Oscilloscope2 current range settings.</td></tr><tr><td>Y axis offset 1</td><td>Oscilloscope1 zero calibration</td></tr></tbody></table>

{% hint style="info" %}
While both oscilloscopes may display the same signal, they are not used to view the same phenomena.

Using [exercise 1](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/wound-rotor-asynchronous-machine-opearting-in-both-phase-shifting-transformer-and-frequency-converte.md) as an example:

To test shifting transformer performance, the rotor voltage must be synchronized to the stator voltage frequency.\
This test is displayed when Trig-Stator is activated.\
On the other hand, to test frequency converter performance, the rotor voltage must be synchronized to its own frequency.\
This test is displayed when Trig-Rotor is activated.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/panels-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.