> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/using-rotor-resistance-to-regulate-wound-rotor-induction-motor-speed.md).

# Using Rotor Resistance To Regulate Wound Rotor Induction Motor Speed

## Objective <a href="#id-7.1-objective" id="id-7.1-objective"></a>

In this exercise, we will work with a speed variation process for industrial drives that use a wound rotor asynchronous machine (not applicable for squirrel cage induction motors).\
We will study how a wound rotor induction motor's speed-torque characteristic moves when we modify the rotor winding resistance while maintaining fixed RMS voltage and frequency.&#x20;

## Initialization of the setup <a href="#id-7.2-initialization-of-the-setup" id="id-7.2-initialization-of-the-setup"></a>

When the simulator is started up, the initial settings on screen are as follows:

* DC voltage supplies SC1, SC2 set to 0 V.
* AC voltage supply SA1, in the “AC Grid” tab, set to 0 V.
* Switches K1, K2, K3 are open: asynchronous machine stator windings are in open-circuit.&#x20;
* Switch K6 is disabled: the asynchronous machine rotor is driven by the DC motor.&#x20;
* Switches K4 and K5 are disabled: asynchronous machine rotor windings are short-circuited.&#x20;
* Trigger switches K10 and K11, in the oscilloscope tabs, are enabled. Triggers are active for oscilloscope groups oscilloscopes1 and oscilloscopes2.&#x20;

### Setup diagram <a href="#id-7.3-setup-diagram" id="id-7.3-setup-diagram"></a>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FL7TFHeQIDxnGLBF4rsPr%2Fa1d0ceef-d6ed-4e4c-9773-6beaecf4fceb.png?alt=media&amp;token=86e5fa8f-61f7-4407-a3a5-d4f2910f600d" alt="" width="480"><figcaption><p><strong>Figure 10</strong>: Electrical diagram setup for exercise 4</p></figcaption></figure>

In this exercise, the asynchronous machine's stator windings are powered with fixed voltage U<sub>s</sub> and frequency f<sub>s</sub> (f<sub>s</sub>=60 Hz) from autotransformer SA1 connected via switch K1.\
Rotor windings are connected to a series of external resistances that can be adjusted using switch K5.\
The asynchronous machine is operating in motor mode, driving a DC generator that is discharging on its fixed load resistance R<sub>ch</sub>.\
Use SC2 to vary the current I<sub>f</sub>. DC voltage source SC1 is set to 0 V for this exercise and does not appear in the diagram when the DC machine is operating in generator mode because it has unidirectional voltage and current (it has a serial diode not shown here).\
This allows us to identify the resistant torque-speed characteristic for several rotor winding resistance values.

## Exercise <a href="#id-7.4-exercise" id="id-7.4-exercise"></a>

1. Restore the setup to its initial conditions, as described; by resetting sources SC3, SC1, SC2 and SA1 and setting all switches to their initial states.
2. Close switch K5 to connect external adjustable resistors in series with rotor winding.
3. Place the "resistor value" dial, In the asynchronous machine panel, in the 2.5 Ω position to add 2.5 Ω resistor in series with the rotor.
4. Select the “AC Grid” tab, then close switch K1 to connect the asynchronous machine’s stator windings to the grid using autotransformer SA1.
5. Using autotransformer SA1, slowly increase voltage U<sub>s</sub> to start the asynchronous machine at low voltage.\
   Apply nominal RMS line-line voltage U<sub>sn</sub> to stator.\
   Make sure to keep I<sub>s</sub> below I<sub>sn</sub> at startup by manually increasing U<sub>s</sub> in proportion to the motor speed increase, otherwise asynchronous machine stator winding fuses F<sub>i1</sub>, F<sub>i2</sub> and F<sub>i3</sub> may be blown, and the drive will stop.\
   If this happens, wait until speed is null and return to initial settings (see Section 7.2).\
   Then, and only then can we simulate replacing fuses by resetting the protection system using push-button K8.
6. Once the steady state is reached and speed is stable, take note of (i) active power P absorbed by the induction motor, (ii) RMS line-line voltage U<sub>s</sub> at stator, (iii) RMS line current I<sub>s</sub> at stator, (iv) torque T<sub>u</sub> and (v) rotation speed N.
7. Vary the DC generator’s resistant speed-torque characteristic slope k(I<sub>f</sub>) by adjusting the current I<sub>f</sub> using SC2.\
   This will define a new operating point for the induction motor's speed-torque for voltage U<sub>s</sub> = U<sub>sn</sub> at a fixed frequency (f<sub>s</sub>=60 Hz) and 2.5 Ω resistor in series with the rotor.\
   Take note of 10 points from this characteristic by increasing the DC generator's current l<sub>f</sub> using source SC2.\
   Take care to maintain a constant voltage U<sub>s</sub> for each operating point using SA1 or the results will be unusable.\
   For each steady state operating point, take note of (i) the active power P absorbed by the induction motor, (ii) RMS line-line voltage U<sub>s</sub> at the stator, (iii) RMS line current I<sub>s</sub> at the stator, (iv) torque T<sub>u</sub>, and (v) rotation speed N.\
   Do not exceed the asynchronous machine’s nominal current I<sub>sn</sub> or the DC generator’s nominal armature I<sub>an</sub>, otherwise, fuses will be blown, and the drive will stop.\
   If this happens, wait until speed is null and return to initial settings (see Section 7.2).\
   Then, and only then, can we simulate replacing fuses by resetting the protection system using push-button K8.\
   Restart the exercise.
8. Restore SC2 to 0 V and stop the motor by bringing voltage U<sub>s</sub> to 0 using SA1.&#x20;
9. Place the "resistor value" dial, in the asynchronous machine panel, in the 1.5 Ω position to add a resistor of 1.5 Ω in series with the rotor\
   Repeat steps 4 to 8.&#x20;
10. Open switches K5 to put the asynchronous machine rotor windings in short-circuit (series resistance with the rotor is null).\
    Repeat steps 4 to 8.

## Lab report <a href="#id-7.5-lab-report" id="id-7.5-lab-report"></a>

1. Present the results obtained in tables (with units in SI).
2. Using the results of the exercise, plot the three characteristics for the induction motor torque-speed T<sub>u</sub>-N with the 3 resistors in series with the rotor 1.5 Ω, 2.5 Ω and 0 (in the case of the rotor short circuit from step 10.
3. Observe how the characteristics for the induction motor torque-speed T<sub>u</sub>-N change with series resistance values in the rotor and with fixed stator voltage U<sub>sn</sub> and frequency f<sub>s</sub>.\
   Can we then assume that the process of using variable voltage to vary speed can be used to drive an elevator with a constant resistant torque (resistant torque-speed characteristic Tr-Ω = constant regardless of Ω)?\
   Would this be a safe solution?\
   Discuss.
4. Calculate the induction motor cosφ power factor for each operating point.\
   Plot all three cosφ-N characteristics with the three resistors in series: 1.5 Ω, 2.5 Ω and 0.\
   Explain the results.
5. Plot the three current-speed characteristics I<sub>s</sub>-N with the three resistors in series: 1.5 Ω, 2.5 Ω and 0.\
   Explain the results.
6. We could also theoretically predict the induction motor’s speed-torque without the load tests run in Section 7.4 by using a steady state asynchronous machine model.\
   All it requires is using a theoretical expression of the induction motor torque T<sub>em</sub> to implement the circuit parameters identified using the low power tests in [this exercise](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/determining-the-asynchronous-machines-steady-state-model-parameters-induction-motor-with-no-load.md) and resistors R<sub>ext</sub> in series with the rotor.\
   Calculate the theoretical electromagnetic torque characteristics T<sub>em</sub>-speed N(rpm) for the induction motor in Section 7.4, using this simplified expression:

   $$\\\[8pt]T\_{em} = \frac{3p}{\omega\_{s}},V\_{s}^{2},\frac{R'*{r}/s}{\left(R*{s} + \frac{R'*{r}}{s}\right)^{2} + \left(X*{s} + X'\_{r}\right)^{2}}\\\[8pt]$$\
   V<sub>s</sub> is the stator RMS line-neutral, p is the number of pair poles for the induction motor and ω<sub>s</sub> is the angular speed.\
   s is the motor slip when it turns at speed N:

   $$\\\[8pt]s = \frac{N\_{s} - N}{N\_{s}}\\\[8pt]$$\
   N<sub>s</sub> is the motor synchronous speed corresponding to f<sub>s</sub>.
7. Superimpose the 3 theoretical motor speed-torque characteristics for the induction motor T<sub>em</sub>-N and the three characteristics T<sub>u</sub>-N from step 2 on the same graph.\
   Compare theoretical and measured characteristics and discuss the differences.

{% hint style="info" %}
The **electromagnetic torque T**<sub>**em**</sub> is different from the torque T<sub>u</sub> imposed by the motor on the shaft.\
The friction torque in the motor bearings and the viscous friction torque exerted by the air on the turning rotor are subtracted from the electromagnetic torque T<sub>em</sub> resulting from the electromechanical energy conversion.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/using-rotor-resistance-to-regulate-wound-rotor-induction-motor-speed.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.