> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/parameter-identification-for-the-steady-state-synchronous-machine-model.md).

# Parameter Identification For the Steady-State Synchronous Machine Model

## Objective <a href="#id-4.1-objective" id="id-4.1-objective"></a>

This exercise presents the implementation of standardized reduced-power tests that allow the user to identify the synchronous machine's steady state model parameters.\
Load tests of high-power synchronous machines are difficult to perform in real life before they are commissioned in power plants or factories since they require high-power test facilities.\
In power engineering, we prefer to estimate load tests using synchronous machine models determined in low power tests to overcome this problem.\
The four identification tests used in this exercise are:  (i) no-load (ii) steady state (iii) short-circuit, and (iv) slip and measuring windings resistance.\
The results of these tests will allow users to calculate the synchronous machine's steady state model parameters: no load characteristic E-Jf at nominal speed and frequency, armature reactances X<sub>d</sub> and X<sub>q</sub> and resistance R<sub>s</sub>.

### 4.2 Initialization of the setup <a href="#id-4.2-initialization-of-the-setup" id="id-4.2-initialization-of-the-setup"></a>

When the simulator is started up, the initial settings on screen are as follows:

1. Continuous voltage supplies SC1, SC2, SC3 set to 0 V.
2. Continuous voltage supply SC4, in the "Measurement Resistors" tab, set to 0 V.
3. Alternative power SA1, in the "AC Grid" tab, set to 0 V.
4. Switches K<sub>1</sub>, K<sub>2</sub>, K<sub>3</sub>, K<sub>4</sub> opened: synchronous generator armature has no load, see [Table 4](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/panels-overview.md#table-4-command-switches-and-led-fuse-status-indicators).
5. Switch K<sub>6</sub> disabled: the synchronous machine rotor is driven by the DC motor, see [Table 4](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/panels-overview.md#table-4-command-switches-and-led-fuse-status-indicators)
6. Switch K<sub>5</sub> disabled: voltage source SC3 powers the synchronous machine field winding, see [Table 4](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/panels-overview.md#table-4-command-switches-and-led-fuse-status-indicators)
7. Trigger switches K<sub>10</sub>, K<sub>11</sub>, K<sub>12</sub>, K<sub>13</sub>, K<sub>14</sub>, in the tab "Oscilloscope", disabled, see [Table 4](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/panels-overview.md#table-4-command-switches-and-led-fuse-status-indicators)
8. Select the "AC Grid" tab in the simulator panel.

## 4.3 Starting and Setting the Driving Speed Using the DC Motor <a href="#id-4.3-starting-and-setting-the-driving-speed-using-the-dc-motor" id="id-4.3-starting-and-setting-the-driving-speed-using-the-dc-motor"></a>

1. Set the variable voltage supply SC2 to provide maximum voltage to the DC motor field, to start with maximum exciter current I<sub>f</sub>.
2. Slowly start the drive using the DC motor by gradually increasing SC1 up to V<sub>a</sub>= 460 V.\
   **Caution**: at startup, the speed and electromotive force in the DC motor armature are null.\
   Current is only limited by the small resistance R<sub>a</sub> of the motor armature. I<sub>a</sub> must be limited at startup by manually increasing V<sub>a</sub> proportionally to the motor speed rising time, otherwise, fuse F<sub>ia</sub> is blown and the drive stops.\
   If this happens, it is necessary to wait until the speed returns to null, then return to the initial settings specified in section 4.2.\
   Then, and only then, can we simulate replacing fuses by resetting the protection system using switch K<sub>8</sub>.
3. To set the drive speed, voltage V<sub>a</sub>, which is supplied by the variable continuous voltage SC1 must be maintained at its nominal value, V<sub>an</sub> = 460 V. Speed is set by adjusting the exciter current I<sub>f</sub>, with SC2.\
   When the I<sub>f</sub> is reduced the drive speed increases and vice versa.\
   Precise speed setting is achieved using the slider bar below SC2.

## 4.4 No Load Test, Constant-speed Characteristics (E-J<sub>f</sub>) of the Synchronous Generator <a href="#id-4.4-no-load-test-constant-speed-characteristics-e-jf-of-the-synchronous-generator" id="id-4.4-no-load-test-constant-speed-characteristics-e-jf-of-the-synchronous-generator"></a>

### 4.4.1 Setup Diagram <a href="#id-4.4.1-setup-diagram" id="id-4.4.1-setup-diagram"></a>

In this exercise, the synchronous machine is operating in generator mode and is driven by the DC motor.\
To adjust generator speed, SC1 is used in conjunction with supply SC2, as described in section 4.3.\
Synchronous machine armature windings are open (no-load).\
This is a low power test since there is no current in the armature.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FacRAHWyB5GmuDorcRDpC%2Fedfa01ff-87c1-46b0-8fc1-a1e41e9a900a.png?alt=media&amp;token=9a75e05d-5cd8-46ce-8ed1-964820b19b6d" alt=""><figcaption><p><strong>Figure 6</strong>: Electrical diagram of synchronous generator with no-load, driven by the DC motor</p></figcaption></figure>

### 4.4.2 Exercise <a href="#id-4.4.2-exercise" id="id-4.4.2-exercise"></a>

1. Drive the synchronous machine at its nominal speed of 1800 rpm using the DC motor, following the procedure set out in section 4.3.
2. Starting at 0, gradually increase current Jf supplied by SC3, which fed the synchronous machine's field winding.\
   **During this test, it is imperative to maintain a constant** **speed of 1800 rpm to maintain the synchronous machine's armature voltage frequency at 60 Hz**.\
   Since the DC motor is not regulated automatically, speed must be manually adjusted at each operating point.\
   Take note of each operation point value: (i) RMS voltage line-line U<sub>s</sub> and (ii) field current J<sub>f</sub>.\
   Since the synchronous machine's armature is open, the RMS voltage line-line U<sub>s</sub> is equal to the no-load electromotive line-line force E.\
   Continue the exercise until maximum J<sub>f</sub> is reached, which is achieved with SC3.
3. Take note of the current J<sub>fo</sub> which makes possible to obtain, at 1800 rpm, an RMS value for the line-line voltage E equal to the synchronous machine's nominal voltage U<sub>sn</sub> (see the machine's data plate).
4. Using the previously measured operating points, we can plot the synchronous machine's no-load characteristic E-J<sub>f</sub> at 1800 rpm.\
   The synchronous machine's equivalent circuit in a steady state corresponds to a line-neutral diagram.\
   Calculate the line-neutral electromotive force from the measured line-line value.

## 4.5 Steady-state short-circuit test, constant-speed characteristic of the synchronous generator I<sub>sc</sub>-J<sub>f</sub> <a href="#id-4.5-steady-state-short-circuit-test-constant-speed-characteristic-of-the-synchronous-generator-isc-j" id="id-4.5-steady-state-short-circuit-test-constant-speed-characteristic-of-the-synchronous-generator-isc-j"></a>

### 4.5.1. Setup Diagram <a href="#id-4.5.1.-setup-diagram" id="id-4.5.1.-setup-diagram"></a>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FgRKMruihx60PlMRcXCRG%2Fbf9cf94b-571b-418a-b5d9-30d32946b4b3.png?alt=media&amp;token=40146e4a-9773-4d21-afd2-366c46aa79da" alt="" width="480"><figcaption><p><strong>Figure 7</strong> : Electrical diagram of the short-circuited synchronous generator driven by the DC motor</p></figcaption></figure>

In this exercise, the synchronous machine is driven by the DC motor.\
Supply SC1 and SC2 are both used to control generator speed, as described in section 4.3.\
Synchronous machine armature windings are short-circuited.\
Switch K<sub>2</sub> is closed.\
This is a low power tests since the voltage at armature terminals are zero.

### 4.5.2. Exercise <a href="#id-4.5.2.-exercise" id="id-4.5.2.-exercise"></a>

1. Reset the setup to its original state, as described in section 4.2, by bringing voltage sources SC3, SC1 and SC2 back to 0 V and by resetting switches to their default settings.
2. With all machines stopped, use switch K<sub>2</sub> to short-circuit all three armature windings.
3. Start the DC motor, as shown in section 4.3, and drive the synchronous machine at 1800 rpm.
4. Gradually increase current J<sub>f</sub> starting from 0 A provided by SC3, which supplies the synchronous machine field winding by using the RMS value of I<sub>s</sub> and the current in the field J<sub>f</sub>. In this test I<sub>s</sub> corresponds to the short-circuit current and is typically called I<sub>ssc</sub>.\
   Continue to increase J<sub>f</sub> until the current of the short-circuited windings reaches the value of the synchronous machine's nominal current I<sub>sn</sub>.\
   Be sure to maintain the speed at 1800 rpm throughout the exercise.
5. Using the previously measured operating points, we can plot the synchronous machine's steady state short-circuit characteristic I<sub>ssc</sub> - J<sub>f</sub> at 1800 rpm.

## 4.6 Slip Test, Saliency Measurement <a href="#id-4.6-slip-test-saliency-measurement" id="id-4.6-slip-test-saliency-measurement"></a>

### 4.6.1. Setup Diagram <a href="#id-4.6.1.-setup-diagram" id="id-4.6.1.-setup-diagram"></a>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FAZuiEsGCWt21gFnJGZWo%2F809dafba-5a0e-4d65-8ac8-564acfbdc970.png?alt=media&amp;token=e14f0f78-24fe-4471-9706-e582a4af830a" alt="" width="480"><figcaption><p><strong>Figure 8</strong>: Electrical diagram of the slip test on the synchronous machine driven by the DC motor</p></figcaption></figure>

In this exercise, the synchronous machine's rotor is driven by the DC motor at a slightly slower speed than the synchronous speed (1800 rpm).\
The synchronous machine armature is fed at reduced voltage from the grid, and switch K<sub>1</sub> is closed.\
Since switch K<sub>5</sub> is open, the synchronous machine's field is not powered and is in parallel with the starting resistor.\
This is an asynchronous operating mode during which the machine reactance varies between X<sub>d</sub> and X<sub>q</sub> at a frequency equal to the difference between the rotor frequency multiplied by the pairs of poles and the grid frequency.\
Since the test is conducted at low voltage levels to limit the RMS current in the armature windings, this is a reduced power test.

### 4.6.2. Exercise <a href="#id-4.6.2.-exercise" id="id-4.6.2.-exercise"></a>

1. Reset the setup to its original state, as described in section 4.2, by bringing voltage sources SC3, SC1 and SC2 back to 0 V and resetting switches to their default conditions.
2. Select the "AC Grid" tab at the right of the panel.\
   Adjust SA1 to 0 V and f<sub>s</sub> to 60 Hz if they are not already set to these values.
3. Enable switch K<sub>5</sub>: the synchronous machine field is no longer powered by SC3 and is connected to the starting resistor.
4. Start the DC machine using the procedure described in section 4.3
5. Set the drive speed to approximately 1790 rpm using the DC motor, following the procedure described in section 4.3.
6. Close switch K<sub>1</sub> to connect the synchronous machine armature to the grid.\
   Energize and **gradually** increase the voltage at stator terminals to approximately 100 V, using transformer SA1 in the "AC Grid" tab.
7. Select the "Oscilloscope2" tab and enable switch K<sub>11</sub> to observe the current waveform that circulates in phase 1 of the synchronous machine's armature.
8. Observe the current in the armature: it varies at f<sub>s,</sub> but its amplitude is modulated by reluctance variations.\
   These variations are due to rotor saliency and oscillate in a low frequency resulting from the difference between the armature power frequency and the rotor electrical frequency multiplied by the pairs of poles.\
   The armature reactance seen from the voltage source SA1, varies at low frequency between X<sub>d</sub> and X<sub>q</sub>.\
   Take note of the minimal (I<sub>s</sub>=I<sub>smin</sub>) and maximal (I<sub>s</sub>=I<sub>smax</sub>) peak values of I<sub>s</sub> from the amplitude modulated current signal.\
   We can deduce that the X<sub>d</sub> /X<sub>q</sub> ratio is essentially equal to the I<sub>smax</sub> / I<sub>smin</sub> ratio.
9. Use Autotransformer SA1 in the "AC Grid" tab to bring the voltage at the stator terminal back to 0 V.\
   Open switch K<sub>1</sub> to disconnect the synchronous machine's armature from the grid.\
   Stop the DC motor by bringing the SC1 voltage down to 0 V.\
   Close switch K<sub>5</sub> and disable switch K<sub>11</sub>.

## 4.7 Armature Resistances Measurement <a href="#id-4.7-armature-resistances-measurement" id="id-4.7-armature-resistances-measurement"></a>

### 4.7.1. Setup Diagram <a href="#id-4.7.1.-setup-diagram" id="id-4.7.1.-setup-diagram"></a>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FzhQYfTqAgc6z7rSA0Zus%2F030cdc58-64f0-4bc9-affc-30fe6b4742b7.png?alt=media&amp;token=c77d65b8-85ba-4c4a-afc2-f673402d448b" alt="" width="404"><figcaption><p><strong>Figure 9</strong>: Wiring diagram for the synchronous machine's armature resistance measurement</p></figcaption></figure>

During the synchronous machine armature windings resistance test, two phases are connected to the continuous voltage source SC4 and the third phase remains open.\
Adding external resistances in series with SC4 the circulating current is limited in the machine windings, each of which present a very low resistance R<sub>s</sub>.\
The synchronous machine rotor is blocked and the source SC3 is at 0 V.

### 4.7.2. Exercise <a href="#id-4.7.2.-exercise" id="id-4.7.2.-exercise"></a>

1. Reset the setup to its original state, as described in section 4.2, by bringing voltage sources back to 0 and resetting switches to their default conditions.
2. With all machines stopped, use switch K<sub>6</sub> to block the synchronous machine rotor.
3. Close switch K<sub>4</sub> and select the "Measurement Resistance" tab at the right of the panel. In this configuration, two phases of the synchronous machine armature are powered by the DC source SC4.\
   Since the synchronous machine armature winding resistance R<sub>s</sub> is low, two limiting resistances were added in series with SC4 to limit the current I<sub>dc</sub> circulating in the windings.\
   A voltmeter directly measures voltage U<sub>dc</sub> at both phase terminals of the armature in which I<sub>dc</sub> is flowing.\
   Gradually increase SC4, starting from 0, so that the DC current I<sub>dc</sub> does not surpass the synchronous machine armature's nominal value I<sub>sn</sub> (see the machine data plate). Measure U<sub>dc</sub> and I<sub>dc</sub>.\
   Calculate the value of resistance R<sub>s</sub> of the armature winding from:\
   $$\\\[8pt]R\_{s} = \frac{U\_{dc}}{2,I\_{dc}}\\\[8pt]$$

## 4.8 Lab report <a href="#id-4.8-lab-report" id="id-4.8-lab-report"></a>

1. Present the no-load test results in tables (SI units).
2. Plot the synchronous machine's no-load characteristic E-J<sub>f</sub> at 1800 rpm.\
   Make sure to calculate the no-load electromotive force E line-neutral from the line-line value measured in the exercise.
3. Present the results of the short-circuit test in tables (SI units).
4. Plot the synchronous machine's steady state short-circuit characteristic I<sub>scc</sub> - J<sub>f</sub> at 1800 rpm.
5. Calculate the synchronous machine armature's winding resistance R<sub>s</sub> based on the test performed in section 4.7.
6. Use the theory learned during the course to show that we can deduce the armature's reactance X<sub>d</sub> from the two previous characteristics (we will calculate the impedance Z<sub>d</sub> from the short-circuit ratio)<sub>.</sub>
7. Calculate the saliency value X<sub>d</sub> /X<sub>q</sub> based on the slip test in section 4.6 and find the value of X<sub>q</sub>.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/parameter-identification-for-the-steady-state-synchronous-machine-model.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.