> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/virtual-test-bench-overview.md).

# Virtual Test Bench Overview

## Diagram and nomenclature of the virtual test bench components <a href="#id-2.1-diagram-and-nomenclature-of-the-virtual-test-bench-components" id="id-2.1-diagram-and-nomenclature-of-the-virtual-test-bench-components"></a>

The virtual test bench implemented in the real-time simulator is shown below:

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FrLECrnPXxTgS75CIIAI8%2Fbdc900ad-b3a4-41b1-aa8d-0c02283dfe74.png?alt=media&amp;token=ca201670-d035-4fc5-9976-cbce0d41f83b" alt="" width="563"><figcaption><p><strong>Figure 1</strong>: Virtual test bench implemented in real-time simulator</p></figcaption></figure>

The main elements of the virtual test bench are:

* A **direct current machine** (DC machine) with independent excitation and an adjustable armature SC1 power voltage source and a power supply voltage from the adjustable field SC2
* A **three-phase synchronous machine** with a wound rotor, with a power supply voltage from adjustable field SC3 that can be disconnected using contactor (<mark style="color:$danger;">**K**</mark><sub><mark style="color:$danger;">**5**<mark style="color:$danger;"></sub>) and an asynchronous starting resistor in parallel on the field.
* A **detachable mechanical coupling** (<mark style="color:$danger;">**K**</mark><sub><mark style="color:$danger;">**6**<mark style="color:$danger;"></sub>) on the shaft connecting both machines.
* A group of **controllable contactors** (<mark style="color:$danger;">**K**</mark><sub><mark style="color:$danger;">**1**<mark style="color:$danger;"></sub>) (<mark style="color:$danger;">**K**</mark><sub><mark style="color:$danger;">**2**<mark style="color:$danger;"></sub>) (<mark style="color:$danger;">**K**</mark><sub><mark style="color:$danger;">**3**<mark style="color:$danger;"></sub>) (<mark style="color:$danger;">**K**</mark><sub><mark style="color:$danger;">**4**<mark style="color:$danger;"></sub>) that allow connecting the synchronous machine’s wye-coupled armature to several devices:
  * A three-phase, wye-connected, adjustable autotransformer SA1 linked to an infinite bus with a user-defined constant frequency and voltage (the default value is f<sub>s</sub> = 60 Hz).
  * An adjustable three-phase, wye-connected, balanced, passive load so that each branch is a serial RLC (R, X<sub>L</sub>, X<sub>C</sub>).
  * A short-circuit three-phase module.
  * An adjustable DC voltage source SC4 in series with two fixed limiting resistors used to measure low resistances in the synchronous machine armature.
* A **protection system** composed of serial fuses with windings from both machines: (F<sub>if</sub> ) (F<sub>ia</sub> ) (F<sub>jf</sub> ) (F<sub>ia</sub> ) (F<sub>ib</sub> ) (F<sub>ic</sub> ). Fuse rating and their I<sup>2</sup>t were adapted to specifications of both machines.

The measurement devices associated to the virtual test bench are only represented by their measured quantities: DC voltages V<sub>a</sub> & V<sub>f</sub>, DC current I<sub>a</sub> & I<sub>f,</sub> rotational speed of shaft N and torque T<sub>u</sub>, RMS value of the voltage line-line U<sub>s</sub> and line current I<sub>s</sub>, total active and reactive power P & Q exchanged at the synchronous machine’s armature. Oscilloscopes not shown on Fig.1 allow users to view or capture waveforms and instantaneous values.

Detailed descriptions of the adjustable elements (power supplies and contactors) are accessible to the user on the [panel of the simulator](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/panels-overview.md).

## Virtual test bench configuration examples based on operating modes <a href="#id-2.2-virtual-test-bench-configuration-examples-based-on-operating-modes" id="id-2.2-virtual-test-bench-configuration-examples-based-on-operating-modes"></a>

### 2.2.1 Synchronous Machine Operating in Generator Mode and Connected to a Grid <a href="#id-2.2.1-synchronous-machine-operating-in-generator-mode-and-connected-to-a-grid" id="id-2.2.1-synchronous-machine-operating-in-generator-mode-and-connected-to-a-grid"></a>

Figure 2 shows an example of how the virtual test bench can be virtually connected by the synchronous machine user in generator mode, connected to the AC grid (open contactors and de-energized circuits are not represented).\
This configuration is used in [**this exercise**](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/synchronous-generator-connected-to-the-grid.md).

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fk3YZSfITCFB3ka8cpEbq%2F9126c88a-5f43-485c-a230-2549598a21d6.png?alt=media&amp;token=c16fce58-cd0f-461a-ba02-073b9dabcec4" alt="" width="480"><figcaption><p><strong>Figure 2</strong>: : Bench configuration to operate the synchronous machine in generator mode, connected to infinite bus</p></figcaption></figure>

### 2.2.2 Synchronous Machine Operating in Generator Mode and Connected to a Passive Load <a href="#id-2.2.2-synchronous-machine-operating-in-generator-mode-and-connected-to-a-passive-load" id="id-2.2.2-synchronous-machine-operating-in-generator-mode-and-connected-to-a-passive-load"></a>

Figure 3 shows an example of how the user can virtually connect the test bench to use the synchronous machine in generator mode, feeding the passive load (open contactors and de-energized circuits are not represented).\
This configuration is used in [**exercise 2**](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-induction-machines-using-real-time-simulation-laboratories/determining-the-asynchronous-machines-steady-state-model-parameters-induction-motor-with-no-load.md).

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Flve9OKCAkxRCyDtnZJXq%2F2c078e05-724a-4e56-8f71-8999f975c8b8.png?alt=media&amp;token=ef0f7aba-6e95-4081-8543-11a099266537" alt="" width="338"><figcaption><p><strong>Figure 3:</strong> Bench configuration to operate the synchronous machine in generator mode feeding a passive load</p></figcaption></figure>

### 2.2.3 Synchronous Machine Operating in Motor Mode <a href="#id-2.2.3-synchronous-machine-operating-in-motor-mode" id="id-2.2.3-synchronous-machine-operating-in-motor-mode"></a>

\
Figure 4 shows an example of how the user can virtually connect the test bench to use the synchronous machine in motor mode (open contactors and de-energized circuits are not represented).\
This configuration is used in laboratory [**exercise 4**](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/synchronous-motor.md).

Note that, in this configuration, the power supplied by the DC machine operating in generator mode is automatically dissipated using a resistance R<sub>ch</sub> on the armature terminals.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FIqmK6krK0xFKTVptAI3W%2F892bdbc8-054e-4ca1-91cf-431f741eeb69.png?alt=media&amp;token=62f24a2d-3122-4337-be0b-8dfe763ba7a0" alt=""><figcaption><p><em><strong>Figure 4:</strong></em> Bench configuration to operate the synchronous machine in motor mode</p></figcaption></figure>

## 2.3 Electric Machines Nameplate Ratings <a href="#id-2.3-electric-machines-nameplate-ratings" id="id-2.3-electric-machines-nameplate-ratings"></a>

### ***Table 1**: Synchronous machine nameplate ratings*

| Parameter              | Value    | Description                                                                |
| ---------------------- | -------- | -------------------------------------------------------------------------- |
| **S**<sub>**n**</sub>  | 10200 VA | Apparent nominal power                                                     |
| **U**<sub>**n**</sub>  | 460 V    | Nominal line-line effective voltage                                        |
| **J**<sub>**fn**</sub> | 10.14 A  | Field current to obtain U<sub>n</sub> no load at no-load and N<sub>n</sub> |
| **f**<sub>**n**</sub>  | 60 Hz    | Nominal frequency                                                          |
| **N**<sub>**n**</sub>  | 1800 rpm | Nominal speed                                                              |

### ***Table 2: DC machine nameplate ratings***

| Parameter              | Value    | Description              |
| ---------------------- | -------- | ------------------------ |
| **P**<sub>**un**</sub> | 16 HP    | Nominal power            |
| **V**<sub>**an**</sub> | 460 V    | Armature nominal voltage |
| **V**<sub>**fn**</sub> | 460 V    | Field nominal voltage    |
| **I**<sub>**fn**</sub> | 1.11 A   | Field nominal current    |
| **N**<sub>**n**</sub>  | 1746 rpm | Nominal speed            |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-machines-courseware/mastering-synchronous-machines-using-real-time-simulation-laboratories/virtual-test-bench-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
