> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-motor-drives/brushed-dc-motor-dcm-drive/panels-overview.md).

# Panels Overview

## Understand the Panel <a href="#understanding-the-panel" id="understanding-the-panel"></a>

The **DC Motor Drive** model file, located in the folder **OP1120 - Electric Motors Drives Courseware,** is **MD\_DCM-version.zip**

When starting the demo, the panel in figure 9 appears first with the default settings.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F49WtviTWmYSx9FC8qWVb%2F67c96f5c-5e91-4b69-9277-c4ccb063b9ce.png?alt=media&amp;token=c0bc2d84-f6f2-4e29-90ec-ae22fa32719d" alt=""><figcaption><p><strong>Figure 9</strong>: Start-Up Panel of the DC Motor Drive Laboratory</p></figcaption></figure>

&#x20;The panel is to be operated as follows:

* In the upper left corner, under **DC Machine (DCM)** the student can set the field voltage of the DC machine and can change the value of the resistive load which can be connected or not.
* In the middle left corner, under **DC Motor Under Test (MUT)**, the student can set the field voltage of the MUT and can block the rotor.
* Under **Voltage Source**, the student can control the voltage magnitude to be applied.
* In the down-left corner, under **Estimation & Command**, the student can access the parameter identification tab, as well as speed and current controls.
* Once an estimation procedure or a control is selected and run, the student can observe the related waveforms and/or displayed values under **Oscilloscopes**.\
  More details about the displayed waveforms and values are discussed later.

## Parameter setup and control

### Control Parameters of the DCM Drive

<table><thead><tr><th width="219.800048828125">Control Parameters</th><th>Tab</th><th width="100">Default Value</th><th>Interval of Variation</th></tr></thead><tbody><tr><td><strong>DCM Field Voltage (V)</strong></td><td>DC Machine</td><td>0</td><td>[0; 460]</td></tr><tr><td><strong>DCM Load Resistance (Ω)</strong></td><td>DC Machine</td><td>20</td><td>[5; 45]</td></tr><tr><td><strong>MUT Filed Voltage (V)</strong></td><td>DC MUT</td><td>0</td><td>[0; 460]</td></tr><tr><td><strong>Reference Current (A)</strong></td><td>Current Control</td><td>0</td><td>[-30; 30]</td></tr><tr><td><strong>Reference speed (rpm)</strong></td><td>Speed Control</td><td>0</td><td>[-1800; 1800]</td></tr></tbody></table>

### Control buttons and  LED fuse status indicators

<table data-search="false"><thead><tr><th width="179.79998779296875">Control Buttons</th><th width="84.20001220703125">Icon</th><th>Associated functions</th></tr></thead><tbody><tr><td><strong>Apply Trigger</strong><br><strong>for Acquisition</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FEP0InqMwAwWO7yL9CpSY%2Fimage.png?alt=media&amp;token=c37be4df-f48c-401b-8f8f-7fdbcedaf272" alt="" data-size="original"></td><td><p>Automatic triggering is disabled. </p><p><em>This button is accessible only in Parameters Identification of inertia under Oscilloscopes.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FfiPgZV13g9SiPAPUWbIu%2Fimage.png?alt=media&amp;token=b46f0997-7d7e-4b29-b255-0ad3231e5296" alt="" data-size="original"></td><td><p>Automatic triggering is enabled.</p><p><em>This button is accessible only in Parameters Identification of inertia under Oscilloscopes.</em></p></td></tr><tr><td><strong>Reset</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fw2zBHPNdTJODJXrPeV0V%2Fimage.png?alt=media&amp;token=ddcd6b65-5ee7-4033-ac23-b186a6c60d01" alt="" data-size="original"></td><td><p>The reset push button is disabled.</p><p><em>This button is accessible and enabled in all scenarios.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F7SGLSBIJvybOhLnC3N3E%2Fimage.png?alt=media&amp;token=5dddfd3a-f77b-4c7e-9ea1-3ff34dc9946f" alt=""></td><td><p>The reset push button is activated and simulates replacement of fuses after a fault.</p><p><em>This button is accessible and enabled in all scenarios.</em></p></td></tr><tr><td><strong>K1</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FeOo3cxnjUlPIXnCb06Um%2Fimage.png?alt=media&amp;token=fcba394d-4cab-47ad-a07c-7e9bc3910a26" alt="" data-size="original"></td><td><p>DCM armature is not connected to the single-phase two-level inverter.</p><p><em>This button is accessible in all scenarios.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F3v56J1CMcYRBb4aNX8ly%2Fimage.png?alt=media&amp;token=bd15c459-58e6-4a71-b80f-56deac6fdeca" alt=""></td><td><p>DCM armature is connected to the single-phase two-level inverter.</p><p><em>This button is accessible in all scenarios.</em></p></td></tr><tr><td><strong>K2</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FEYcbPbmrBu07tpJFJL8i%2Fimage.png?alt=media&amp;token=74c521ba-bda9-444e-83aa-14678ed26dae" alt="" data-size="original"></td><td><p>MUT armature is not connected to the single-phase two-level inverter.</p><p><em>This button is accessible in all scenarios</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F4of7H4AFj6ui6JX5Jrli%2Fimage.png?alt=media&amp;token=c10fc49f-d6a7-4b27-93a3-afee18b284c4" alt=""></td><td><p>MUT armature is connected to the single-phase two-level inverter.</p><p><em>This button is accessible in all scenarios</em></p></td></tr><tr><td><strong>K3</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FmkOkb9hwxCzFmTrGLBoL%2Fimage.png?alt=media&amp;token=759a9365-c167-4891-bd3d-8b506a661be0" alt="" data-size="original"></td><td><p>DCM load resistance is disconnected.</p><p><em>This button is accessible in all scenarios.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FC8AMnPP3a059f1VXGJ9P%2Fimage.png?alt=media&amp;token=593d6999-b243-4032-a79c-7d8fedc0f7dc" alt=""></td><td><p>DCM load resistance is connected.</p><p><em>This button is accessible in all scenarios.</em></p></td></tr><tr><td><strong>Speed Control</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FZ4kHt4lzScMcOsINQBbl%2Fimage.png?alt=media&amp;token=f55b1666-8a0c-4dda-9e0a-f1fb5154df9a" alt="" data-size="original"></td><td><p>Speed control is disabled.</p><p><em>This button is accessible in Speed Control only.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fa6dAGvzb4em7CpE3y2Vm%2Fimage.png?alt=media&amp;token=19033b6a-30c3-4085-b84d-fd72f88c3bb0" alt=""></td><td><p>Speed control is enabled.</p><p><em>This button is accessible in Speed Control only.</em></p></td></tr><tr><td><strong>Current Control</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FmbhWLzHaNgl1SCURRwFX%2Fimage.png?alt=media&amp;token=4f169345-12a2-4682-b4c9-1bb6e3334f2e" alt="" data-size="original"></td><td><p>Current control is disabled.</p><p><em>This button is accessible in Current Control only.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FUdS0MeabbIUlQORTi6Tp%2Fimage.png?alt=media&amp;token=a3691caa-5762-4914-9b72-10844a7e9c19" alt=""></td><td><p>Current control is enabled.</p><p><em>This button is accessible in Current Control only.</em></p></td></tr><tr><td><strong>Block Rotor</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FgrPQX4JZLmL2kbhju1WV%2Fimage.png?alt=media&amp;token=7f1630f9-ef7c-4b66-b6d4-1bc97e040121" alt="" data-size="original"></td><td><p>The rotor of the DC motor under test is not blocked.</p><p><em>This button is accessible in all scenarios.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FcnBsUq2N0VAVOOusuQOv%2Fimage.png?alt=media&amp;token=6673eecb-dfe7-4289-8fab-bda1280bf6d3" alt=""></td><td><p>The rotor of the DC motor under test is blocked.</p><p><em>This button is accessible in all scenarios.</em></p></td></tr><tr><td><strong>F_Ia</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FvZPBhmtm5lQ8jK1NJvmI%2Fimage.png?alt=media&amp;token=4281c386-12b8-45bd-9d59-c1d67edb2eff" alt="" data-size="original"></td><td>The DC machine’s armature fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FT5CuacUbyud4oWMVPl3w%2Fimage.png?alt=media&amp;token=fb6e01a3-e9ad-49d1-adb9-2293a2435451" alt="" data-size="original"></td><td>The DC machine’s armature fuse is intact.</td></tr><tr><td><strong>F_If</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FNLTY182G2wZdcbQN9Ojf%2Fimage.png?alt=media&amp;token=cb6318f3-564b-437c-8c2d-4544b7f99f1a" alt="" data-size="original"></td><td>The DC machine’s field fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FXFSU8NlzBtAKjVQtOEwX%2Fimage.png?alt=media&amp;token=ba2d05f4-ebff-4c57-bb41-252543f11b69" alt="" data-size="original"></td><td>The DC machine’s field fuse is intact.</td></tr><tr><td><strong>F_ia</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FViMBJbpKJLjj3Fm3VGFm%2Fimage.png?alt=media&amp;token=19af9d45-27e6-4660-882a-1a154936d757" alt="" data-size="original"></td><td>The MUT armature fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fr3wAa4sFCT4f4AQn3acm%2Fimage.png?alt=media&amp;token=c9a17656-7bfe-4794-a0cb-a7894b5a17d2" alt="" data-size="original"></td><td>The MUT armature fuse is intact.</td></tr><tr><td><strong>F_if</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FkMHW5L8aGLyxkQZgU6sS%2Fimage.png?alt=media&amp;token=9f5310ac-3e9d-4666-95d0-930d4e1f0ef4" alt="" data-size="original"></td><td>The MUT field fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FbXPxRhUsMQ2fMDgDqAPV%2Fimage.png?alt=media&amp;token=5cb98710-fa41-468c-a95d-069bdd7243bd" alt="" data-size="original"></td><td>The MUT field fuse is intact.</td></tr></tbody></table>

### Content of Displays of the DCM Drive

Several displays can be seen in figure 9 above. The content of these displays is summarized in table 3.

<table data-search="false"><thead><tr><th width="180">Tab</th><th width="120">Display</th><th>Content of Displays</th></tr></thead><tbody><tr><td><strong>DCM</strong></td><td>Va</td><td>Voltage at machine armature terminals.</td></tr><tr><td><strong>DCM</strong></td><td>Ia</td><td>DCM armature current.</td></tr><tr><td><strong>DCM</strong></td><td>Vf</td><td>Voltage at field terminals.</td></tr><tr><td><strong>DCM</strong></td><td>If</td><td>Field current.</td></tr><tr><td><strong>Shaft</strong></td><td>N</td><td>Drive rotation speed.</td></tr><tr><td><strong>Shaft</strong></td><td>Tem</td><td>DC machine resistive torque.</td></tr><tr><td><strong>MUT</strong></td><td>Va</td><td>Voltage at MUT armature terminals.</td></tr><tr><td><strong>MUT</strong></td><td>Ia</td><td>MUT armature current.</td></tr><tr><td><strong>MUT</strong></td><td>Vf</td><td>Voltage at field terminals.</td></tr><tr><td><strong>MUT</strong></td><td>If</td><td>Field current.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>K</strong></em><sub><em><strong>e</strong></em></sub></td><td>Va</td><td>Voltage at MUT armature terminals.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>K</strong></em><sub><em><strong>e</strong></em></sub></td><td>N</td><td>MUT speed.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>R</strong></em><sub><em><strong>a</strong></em></sub></td><td>Va</td><td>Voltage at MUT armature terminals.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>R</strong></em><sub><em><strong>a</strong></em></sub></td><td>N</td><td>MUT speed.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>R</strong></em><sub><em><strong>a</strong></em></sub></td><td>Ia</td><td>MUT armature current.</td></tr><tr><td><strong>Parameters Identification T</strong><sub><em><strong>f</strong></em></sub><strong> &#x26; </strong><em><strong>B</strong></em></td><td>N</td><td>MUT speed.</td></tr><tr><td><strong>Parameters Identification T</strong><sub><em><strong>f</strong></em></sub><strong> &#x26; </strong><em><strong>B</strong></em></td><td>Tem</td><td>Electromagnetic torque of the MUT.</td></tr><tr><td><strong>Parameters Identification T</strong><sub><em><strong>f</strong></em></sub><strong> &#x26; </strong><em><strong>B</strong></em></td><td>Ia</td><td>MUT armature current.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>J</strong></em></td><td>Ia</td><td>MUT armature current.</td></tr></tbody></table>

### Content of scopes and displayed waveforms

Table 4 presents the content of scopes for different tabs under “**Oscilloscopes**”.\
It should be noted that the “Parameters Identification *L*<sub>*a*</sub> and *J”* tabs have only one scope, and their scope is referred to as Scope<sub>1</sub>.\
For the “Current Control” tab, there are two scopes. The top one is referred as Scope<sub>11</sub> and the bottom one as Scope<sub>21</sub>.

<table><thead><tr><th width="180">Oscilloscopes</th><th width="120">Scope</th><th>Content of Scopes &#x26; Displayed Waveforms</th></tr></thead><tbody><tr><td><strong>Parameters Identification </strong><em><strong>L</strong></em><sub><em><strong>a</strong></em></sub></td><td>Scope<sub>1</sub></td><td>MUT armature current.</td></tr><tr><td><strong>Parameters Identification </strong><em><strong>J</strong></em></td><td>Scope<sub>1</sub></td><td>MUT speed.</td></tr><tr><td><strong>Current Control</strong></td><td>Scope<sub>11</sub></td><td>Reference and measured currents (triggered).</td></tr><tr><td><strong>Current Control</strong></td><td>Scope<sub>21</sub></td><td>Reference and measured currents.</td></tr></tbody></table>

### Content of scopes and displayed waveforms of the DCM drive

Regarding the scopes under “**Speed Control**” tab, the two scopes at the top are referred to as Scope<sub>1</sub> and Scope<sub>2</sub>, while the bottom one as Scope<sub>3</sub>.\
Table 5 summarizes the content of scopes for the “Speed Control” tab.

<table><thead><tr><th width="180">Oscilloscopes</th><th width="120">Scope</th><th>Content of Scopes &#x26; Displayed Waveforms</th></tr></thead><tbody><tr><td><strong>Speed Control</strong></td><td>Scope<sub>1</sub></td><td>Reference and measured currents (triggered).</td></tr><tr><td><strong>Speed Control</strong></td><td>Scope<sub>2</sub></td><td>Reference and measured speeds (triggered).</td></tr><tr><td><strong>Speed Control</strong></td><td>Scope<sub>3</sub></td><td>Reference and measured speeds.</td></tr></tbody></table>

{% hint style="info" %}
The scopes that are automatically triggered allow students to see step change in current and speed.\
Also, zoom-in capability options are enabled for these scopes.
{% endhint %}

####

#### ***Table 6: Parameters of the DC Motor Under Test***

| **Armature windings Resistance** | 1.5 Ω          |
| -------------------------------- | -------------- |
| **Armature Inductance**          | 0.04 H         |
| **Field windings Resistance**    | 414.41 Ω       |
| **Field Inductance**             | 2.44 H         |
| **Back-emf Constant**            | 2.7088 V.s/rad |
| **Base Speed**                   | 1800 rpm       |

#### ***Table 7**: DCM and MUT Nameplate Ratings*

| **Nominal Power**            | 16 HP    |
| ---------------------------- | -------- |
| **Armature Nominal Voltage** | 460 V    |
| **Field Nominal Voltage**    | 460 V    |
| **Field Nominal Current**    | 1.11 A   |
| **Nominal Speed**            | 1746 rpm |

#### ***Table 8**: Single-phase Two-level Inverter Nameplate Ratings*

| **DC Input**    |         |
| --------------- | ------- |
| Voltage DC      | 460 V   |
| Maximum Current | 31.5 A  |
| **AC Output**   | 1-phase |
| Maximum Voltage | 460 V   |
| Maximum Current | 31.5 A  |
| Power           | 14.5 kW |

#### ***Table 9**: Test Bench Mechanical Parameters*

| **Total Inertia**  | 0.31 kg.m<sup>2</sup> |
| ------------------ | --------------------- |
| **Total Friction** | 0.0135 N.m            |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-motor-drives/brushed-dc-motor-dcm-drive/panels-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.