> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-motor-drives/doubly-fed-induction-machine-dfim-drive/panels-overview.md).

# Panels Overview

## Understand the panel <a href="#understanding-the-panel" id="understanding-the-panel"></a>

The **DFIM Drive Hight Power** model file, located in the folder **OP1120 - Electric Motors Drives Courseware,** is **MD\_DFIM-version.zip**

When starting the demo, the panel in figure 8 appears first with the defaultsettings.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FzkZpAFgkRHftN7AUCAmk%2Fc65c072d-e182-4335-a1f0-2538ed9af7dc.png?alt=media&amp;token=53b35673-75b7-47f8-9d1e-d9f4ba2b7470" alt=""><figcaption><p><strong>Figure 8</strong>: Start-Up Panel of the DFIM Drive Laboratory</p></figcaption></figure>

The panel is to be operated as follows:

* In the left corner, under **DFIM control** the student can set the control parameters such as input torque, reference speed, and reference current *I*<sub>*d*</sub>.\
  Table 1 summarizes these parameters, while table 2 presents the descriptions of control buttons and the fuses.
* Once a value has been applied for a control parameter, the student can observe the related waveforms under **Oscilloscopes**.\
  Table 3 presents the content of scopes of each tab under **Oscilloscopes**.

### Control parameters of the DFIM drive

| Control Parameters                              | Default Value | Interval of Variation |
| ----------------------------------------------- | ------------- | --------------------- |
| **Input Torque (p.u.)**                         | 0             | \[-0.6; 0.6]          |
| **Reference Speed (rpm)**                       | 270           | \[194; 304]           |
| **I**<sub>**d**</sub>**&#x20;Reference (p.u.)** | 0             | \[-0.5; 0.5]          |

### Control buttons and LED fuse status indicators

On scope localization, the indices used will be like those of matrix elements.\
Hence, the scope located at the upper left corner (first row, first column) is denoted Scope<sub>11</sub>, while the scope in the upper right corner (first row, second column) is Scope<sub>12</sub>.\
By the same token, the scope in the lower left corner is Scope<sub>21</sub> while the scope in the lower right corner is Scope<sub>22</sub>.\
Table 3 summarizes the content of scopes.

### Content of scopes and displayed waveforms

| Oscilloscopes                                                            | Scope              | Content of Scopes & Displayed Waveforms            |
| ------------------------------------------------------------------------ | ------------------ | -------------------------------------------------- |
| <p><strong>DFIM Electrical</strong><br><strong>Measurements</strong></p> | Scope<sub>11</sub> | Line-to-neutral stator voltages.                   |
|                                                                          | Scope<sub>21</sub> | Rotor currents at phases A, B, and C.              |
|                                                                          | Scope<sub>12</sub> | Line-to-neutral rotor voltages.                    |
|                                                                          | Scope<sub>22</sub> | Stator currents at phases A, B, and C.             |
| **DFIM Control**                                                         | Scope<sub>11</sub> | Reference and measured speeds.                     |
|                                                                          | Scope<sub>21</sub> | Reference and measured *I*<sub>*d*</sub> currents. |
|                                                                          | Scope<sub>12</sub> | Reference and measured *I*<sub>*q*</sub> currents. |
|                                                                          | Scope<sub>22</sub> | Reference and measured torques.                    |
| **Triggering Scopes**                                                    | Scope<sub>11</sub> | Reference and measured speeds.                     |
|                                                                          | Scope<sub>21</sub> | Reference and measured *I*<sub>*d*</sub> currents. |
|                                                                          | Scope<sub>12</sub> | Reference and measured *I*<sub>*q*</sub> currents. |
|                                                                          | Scope<sub>22</sub> | Reference and measured torques.                    |

Finally, the parameter values and nominal ratings of the DFIM simulated as part of this laboratory are presented in table 4.

{% hint style="info" %}
The scopes under “Triggering Scopes” are automatically triggered, allowing students to see step change in current, torque, and speed.\
Also, zoom-in capability options are enabled for these scopes.
{% endhint %}

## DFIM Parameters and Nameplate Ratings

<table data-header-hidden data-search="false"><thead><tr><th></th><th></th></tr></thead><tbody><tr><td><strong>Apparent Nominal Power</strong></td><td>50 MVA</td></tr><tr><td><strong>Power Factor</strong></td><td>0.9</td></tr><tr><td><strong>Nominal Line-to-line Stator Voltage</strong></td><td>15750 V</td></tr><tr><td><strong>Nominal Stator Current</strong></td><td>1850 A</td></tr><tr><td><strong>Nominal Rotor Current</strong></td><td>1950 A</td></tr><tr><td><strong>Estimated Stator Flux</strong></td><td>34.11 Wb</td></tr><tr><td><strong>Nominal Speed</strong></td><td>277 rpm</td></tr><tr><td><strong>Nominal Torque</strong></td><td>1724200 Nm</td></tr><tr><td><strong>Estimated Stator Flux</strong></td><td>34.11 Wb</td></tr><tr><td><strong>Number of Poles</strong></td><td>13</td></tr><tr><td><strong>Stator Resistance</strong></td><td>0.104 Ω</td></tr><tr><td><strong>Stator Inductance</strong></td><td>5.4375 mH</td></tr><tr><td><strong>Rotor Resistance</strong></td><td>1.8125 Ω</td></tr><tr><td><strong>Rotor Inductance</strong></td><td>5.4375 mH</td></tr><tr><td><strong>Magnetizing Inductance</strong></td><td>0.05 H</td></tr><tr><td><strong>Moment of Inertia</strong></td><td>40,000 kg.m<sup>2</sup></td></tr><tr><td><strong>Friction Factor</strong></td><td>0.0006 N.m.s</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-motor-drives/doubly-fed-induction-machine-dfim-drive/panels-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.