> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/electric-motor-drives/squirrel-cage-induction-motor-drive/panels-overview.md).

# Panels Overview

## Understand the panel <a href="#understanding-the-panel" id="understanding-the-panel"></a>

The **InductionMotor\_Drive** model file, located in the folder **OP1120 - Electric Motors Drives Courseware,** is **MD\_inductionmotor-version.zip**

When starting the demo, the panel in figure 7 appears first with the default settings.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FdBhvzwnZVQmLC8TNr4vq%2Fc33dd1bc-1134-42f6-bde4-a8276c124d9e.png?alt=media&amp;token=1a5124fa-2cfa-4681-8a95-875dfdd1b6ed" alt=""><figcaption><p><strong>Figure 7</strong>: Start-Up Panel of the Induction Motor Drive Laboratory</p></figcaption></figure>

The panel is to be operated as follows:

* In the upper left corner, under **DC Machine (DCM)**, the student can set the field voltage of the DC machine and can change the value of the resistive load.
* In the middle left corner, under **Command**, the student can select the type of control to be applied to the induction motor.
* Under each command tab, there are control parameters and/or control buttons that are summarized in tables 4 and 5.
* Once a control is selected and applied, the student can observe the related waveforms under **Oscilloscopes**.\
  More details about the displayed waveforms are discussed later.

Table 4 summarizes the control parameters, while table 5 is dedicated for the control buttons.

### Control parameters of the IM drive

| Control Parameters          | Tab              | Default Value | Interval of Variation |
| --------------------------- | ---------------- | ------------- | --------------------- |
| **DCM Field Voltage (V)**   | DC Machine (DCM) | 0             | \[0; 460]             |
| **DCM Variable Load (Ω)**   | DC Machine (DCM) | 0             | \[0; 20]              |
| **Inverter frequency (Hz)** | Command V/F      | 0             | \[0; 60]              |
| **Reference torque (Nm)**   | Torque Control   | 0             | \[-55; 55]            |
| **Reference speed (rpm)**   | Speed Control    | 0             | \[-2500; 2500]        |

### Control buttons and LED fuse status indicators of the IM drive

<table data-search="false"><thead><tr><th width="119.2222900390625">Control Buttons</th><th width="110.3333740234375"></th><th>Associated functions</th></tr></thead><tbody><tr><td><strong>TRIGGER</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FLiej9zKvUK8ec7oIYhLi%2Fimage.png?alt=media&amp;token=c970875f-4d02-490f-96bb-f0c967b768b9" alt="" data-size="original"></td><td><p>The waveforms are not triggered. They “move” </p><p><em>This button is accessible only for the V/F Control Oscilloscopes.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FvbZLXaQ5s9a7QEDVfDFU%2Fimage.png?alt=media&amp;token=d73f6f59-2ae1-4708-a3db-54202fe4c86c" alt="" data-size="original"></td><td><p>The waveforms are triggered with respect to a reference signal. </p><p><em>This button is accessible only for the V/F Control Oscilloscopes.</em></p></td></tr><tr><td><strong>V/F control</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FaIBkJ3uWYlrtz9Bq24KW%2Fimage.png?alt=media&amp;token=c917e44c-35e9-47ea-b007-df926849de1a" alt="" data-size="original"></td><td><p>V/F control is disabled. </p><p><em>This button is accessible in V/F Command only.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F5NTODzVnB8CUFuzPEHTj%2Fimage.png?alt=media&amp;token=08128162-13cc-4c6b-a993-9e8ce98c961f" alt="" data-size="original"></td><td><p>V/F control is enabled. </p><p><em>This button is accessible in V/F Command only.</em></p></td></tr><tr><td><strong>Reset</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FOV2KivmLqsoOuilhWhNl%2Fimage.png?alt=media&amp;token=626888d2-7f96-4a6e-aa21-5d831a4c80d3" alt="" data-size="original"></td><td><p>The reset push button is disabled. </p><p><em>This button is accessible and enabled in all scenarios</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FG8ghplqQZonUsFZxogge%2Fimage.png?alt=media&amp;token=a4a14b7d-706b-4a75-a90f-7360538e9296" alt="" data-size="original"></td><td><p>The reset push button is activated and simulates replacement of fuses after a fault. </p><p><em>This button is accessible and enabled in all scenarios</em></p></td></tr><tr><td><strong>ACTIVATE</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FVxBlPYq461PlgleAqTVa%2Fimage.png?alt=media&amp;token=355cff2e-a920-4602-a607-84bf96fd1519" alt="" data-size="original"></td><td><p>Flux control is disabled. </p><p><em>This button is accessible in Flux Control only.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FLklccKsSTL5Tg3SdsKf2%2Fimage.png?alt=media&amp;token=bf94da82-4b56-4ee3-ad64-0e4416ca2bcf" alt="" data-size="original"></td><td><p>Flux control is enabled. </p><p><em>This button is accessible in Flux Control only.</em></p></td></tr><tr><td><strong>enable</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FwqyJla6BHAHtE1OU47wO%2Fimage.png?alt=media&amp;token=e8d1b2d6-da5b-4121-988b-d0ac564661fe" alt="" data-size="original"></td><td><p>Torque control is disabled. </p><p><em>This button is accessible in Torque Control only.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FmLfxBvXTjWwagtlEQh1r%2Fimage.png?alt=media&amp;token=3d45f224-40d9-40a3-a537-747fc3045a06" alt="" data-size="original"></td><td><p>Torque control is enabled. </p><p><em>This button is accessible in Torque Control only.</em></p></td></tr><tr><td><strong>ENABLE</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F1svnKT5E4NFiEnVx0dA0%2Fimage.png?alt=media&amp;token=ab5f8277-85dc-42d9-8441-63eac86f6a57" alt="" data-size="original"></td><td><p>Speed control is disabled. </p><p><em>This button is accessible in Speed Control only.</em></p></td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FM4YOYezLaMEaQxWbxFxn%2Fimage.png?alt=media&amp;token=8b952440-6fbc-4029-b024-cf1ea3651a14" alt="" data-size="original"></td><td><p>Speed control is enabled. </p><p><em>This button is accessible in Speed Control only.</em></p></td></tr><tr><td><strong>Fia</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F2AjUw0iLRilufBKKZiuH%2Fimage.png?alt=media&amp;token=310174ed-e10f-47f5-889b-c958abdd8549" alt="" data-size="original"></td><td>The DC machine’s armature fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FgchFRks2AVnm97yr9YFv%2Fimage.png?alt=media&amp;token=19df0593-065e-4f64-bf43-cf4bb82c32b3" alt="" data-size="original"></td><td>The DC machine’s armature fuse is intact.</td></tr><tr><td><strong>Fif</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FRCUv9PM0Taqd9Xlpib6C%2Fimage.png?alt=media&amp;token=9f2ac6ff-7bce-414b-b920-d0a9a7a87af7" alt="" data-size="original"></td><td>The DC machine’s field fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F1RoXJs5Cf6gpknBRig4Z%2Fimage.png?alt=media&amp;token=5e963933-9b06-431c-8609-b1e5f1bef598" alt="" data-size="original"></td><td>The DC machine’s field fuse is intact.</td></tr><tr><td><strong>Fi1</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FZMMhjKPGx6XV5DDHluH6%2Fimage.png?alt=media&amp;token=e196bd6b-fbb3-4f64-a1ea-c18024d271ab" alt="" data-size="original"></td><td>The induction machine’s stator phase 1 fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F9qR5BB1Ld7HnEcth5c5f%2Fimage.png?alt=media&amp;token=978599ee-9a59-42f4-b10c-68dfd5146114" alt="" data-size="original"></td><td>The induction machine’s stator phase 1 is intact.</td></tr><tr><td><strong>Fi2</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FYBDUDAxRm1WvMy2ozzS7%2Fimage.png?alt=media&amp;token=9b430293-777b-4ea4-b936-176f57ccb194" alt="" data-size="original"></td><td>The induction machine’s stator phase 2 fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FjqUoPbTqnU2nV1EVdouz%2Fimage.png?alt=media&amp;token=845939d6-0e55-4f50-9e89-5e07f008b134" alt="" data-size="original"></td><td>The induction machine’s stator phase 2 is intact.</td></tr><tr><td><strong>Fi3</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FI7N7nXtt22MKOJZwx8li%2Fimage.png?alt=media&amp;token=8d7d705c-8c4e-49a4-a689-3955ecc9f7d6" alt="" data-size="original"></td><td>The induction machine’s stator phase 3 fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fpevc7rAeeyj19qxmjafh%2Fimage.png?alt=media&amp;token=1c426caf-397f-4ca7-8f98-846c8c3c6a05" alt="" data-size="original"></td><td>The induction machine’s stator phase 2 is intact.</td></tr><tr><td><strong>Control Choice</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FztHdJfRDuzXoDNoM8g0V%2Fimage.png?alt=media&amp;token=88dd0074-b064-4c63-bf89-9835c79ffd37" alt="" data-size="original"></td><td>Allow to implement the flux, torque, and speed controllers manually (User) or automatically (Predefined).</td></tr></tbody></table>

Several displays can be seen in [**figure 7**](#understanding-the-panel). The content of these displays is summarized in table 6.

## Content of displays of the IM drive

<table data-search="false"><thead><tr><th>Tab</th><th>Display</th><th>Content of Displays</th></tr></thead><tbody><tr><td><strong>DCM</strong></td><td>Va</td><td>Voltage at machine armature terminals.</td></tr><tr><td><strong>DCM</strong></td><td>Ia</td><td>DCM armature current.</td></tr><tr><td><strong>DCM</strong></td><td>Vf</td><td>Voltage at field terminals.</td></tr><tr><td><strong>DCM</strong></td><td>If</td><td>Field current.</td></tr><tr><td><strong>Shaft</strong></td><td>N</td><td>Drive rotation speed.</td></tr><tr><td><strong>Shaft</strong></td><td>Tem</td><td>DC machine resistive torque.</td></tr><tr><td><strong>IM</strong></td><td>Us</td><td>RMS line-line voltage at stator terminals.</td></tr><tr><td><strong>IM</strong></td><td>Is</td><td>RMS line current in stator.</td></tr><tr><td><strong>IM</strong></td><td>Ps</td><td>Induction machine active power.</td></tr><tr><td><strong>IM</strong></td><td>Qs</td><td>Induction machine reactive power.</td></tr><tr><td><strong>Oscilloscopes V/F</strong><br><strong>Control</strong></td><td>Ratio V/F</td><td>Ratio between voltage and frequency in [V/Hz].</td></tr></tbody></table>

On scope localization (for V/F Control and Flux Control), the indices used will be like those of matrix elements.\
Hence, the scope located in the upper left corner (first row, first column) is denoted Scope<sub>11</sub>, while the scope in the upper right corner (first row, second column) is Scope<sub>12</sub>.\
By the same token, the scope in the lower left corner is Scope<sub>21</sub> while the scope in the lower right corner is Scope<sub>22</sub>.\
Table 7 summarizes the content of scopes for the “V/F Control and Flux Control” tabs.

### Content of scopes and displayed waveforms

<table data-search="false"><thead><tr><th width="195.6666259765625">Oscilloscopes</th><th width="89.888916015625">Scope</th><th>Content of Scopes &#x26; Displayed Waveforms</th></tr></thead><tbody><tr><td><strong>V/F Control</strong></td><td>Scope<sub>11</sub></td><td>Stator currents at phases A, B and C.</td></tr><tr><td></td><td>Scope<sub>21</sub></td><td>DC machine and induction motor speeds.</td></tr><tr><td></td><td>Scope<sub>12</sub></td><td>Line-to-line stator voltages Us<sub>AB</sub>, Us<sub>BC</sub>, and Us<sub>CA</sub>.</td></tr><tr><td></td><td>Scope<sub>22</sub></td><td>DC machine resistive torque.</td></tr><tr><td><strong>Flux Control</strong></td><td>Scope<sub>11</sub></td><td>Rotor flux in d-axis and rotor flux in q-axis.</td></tr><tr><td></td><td>Scope<sub>21</sub></td><td>Stator current d-axis and stator current in q-axis.</td></tr><tr><td></td><td>Scope<sub>12</sub></td><td>Triggered rotor fluxes in dq-axes.</td></tr><tr><td></td><td>Scope<sub>22</sub></td><td>Stator voltage in d-axis and stator voltage in q-axis.</td></tr></tbody></table>

Regarding the scopes under “Torque Control, Speed Control, and Triggering Scopes” tabs, a column arrangement is considered, as presented in figure 8 below.\
Going from top to down, the first scope of the **first column** is referred to as Scope<sub>1</sub>, the second one Scope<sub>2</sub>, and the third one Scope<sub>3</sub>.; while the two scopes of the **second column** are referred to as Scope<sub>4</sub> and Scope<sub>5</sub>.\
Table 8 summarizes the content of scopes for the “Torque Control, Speed Control, and Triggering Scopes” tabs.

{% hint style="info" %}
The scopes under “Triggering Scopes” are automatically triggered, allowing students to see step change in toque, speed, etc.\
Also, zoom-in capability options are enabled for these scopes.
{% endhint %}

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FFR0jiaxH9Q7zCXt5wqD7%2F52a7b7cd-4849-46d5-af20-0bdea28b728a.png?alt=media&amp;token=1d9061f5-3709-4feb-afd4-287db5fd6d9a" alt=""><figcaption><p><strong>Figure 8</strong>: Column Arrangement of Scopes under Torque Control Panel</p></figcaption></figure>

### Content of scopes and displayed waveforms of the IM drive

<table data-search="false"><thead><tr><th width="165.4444580078125">Oscilloscopes</th><th width="102.77777099609375">Scope</th><th>Content of Scopes &#x26; Displayed Waveforms</th></tr></thead><tbody><tr><td><strong>Torque Control</strong></td><td>Scope<sub>1</sub></td><td>Reference and measured torques.</td></tr><tr><td></td><td>Scope<sub>2</sub></td><td>Induction motor speed.</td></tr><tr><td></td><td>Scope<sub>3</sub></td><td>Stator current d-axis and stator current in q-axis.</td></tr><tr><td></td><td>Scope<sub>4</sub></td><td>Rotor flux in d-axis and rotor flux in q-axis.</td></tr><tr><td></td><td>Scope<sub>5</sub></td><td>Stator voltage in d-axis and stator voltage in q-axis.</td></tr><tr><td><strong>Speed Control</strong></td><td>Scope<sub>1</sub></td><td>Reference and measured torques.</td></tr><tr><td></td><td>Scope<sub>2</sub></td><td>Reference and measured speeds of the induction motor.</td></tr><tr><td></td><td>Scope<sub>3</sub></td><td>Stator current d-axis and stator current in q-axis.</td></tr><tr><td></td><td>Scope<sub>4</sub></td><td>Rotor flux in d-axis and rotor flux in q-axis.</td></tr><tr><td></td><td>Scope<sub>5</sub></td><td>Stator voltage in d-axis and stator voltage in q-axis.</td></tr><tr><td><strong>Triggering Scopes</strong></td><td>Scope<sub>1</sub></td><td>Reference and measured torques.</td></tr><tr><td></td><td>Scope<sub>2</sub></td><td>Reference and measured speeds of the induction motor.</td></tr><tr><td></td><td>Scope<sub>3</sub></td><td>Stator current d-axis and stator current in q-axis.</td></tr><tr><td></td><td>Scope<sub>4</sub></td><td>Rotor flux in d-axis and rotor flux in q-axis.</td></tr><tr><td></td><td>Scope<sub>5</sub></td><td>Stator voltage in d-axis and stator voltage in q-axis.</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/electric-motor-drives/squirrel-cage-induction-motor-drive/panels-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.