> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/single-phase-systems/single-phase-rlc-circuit-in-steady-state-power-factor-correction.md).

# Single-Phase RLC Circuit in Steady-State, Power Factor Correction

## Objective <a href="#objective.1" id="objective.1"></a>

This second exercise aims to explore and acquire the necessary knowledge for a better understanding of power factor correction in a single-phase RLC alternating current circuit.

## Preparatory activities <a href="#preparatory-activities.2" id="preparatory-activities.2"></a>

In order to set up the required circuit and gain a better understanding, theoretical exercises are required. The values of the circuit elements are as follows:

* $$U = 230,\text{V}$$
* $$f = 50,\text{Hz}$$
* $$I\_{\max} = 0.67,\text{A}$$
* $$P\_{tot} = 70,\text{W}$$

For the initial questions 1 and 2, the capacitance (C) is neglected.

1. Calculate the power factor cos⁡(φ), the phase angle (φ) between current and voltage, the apparent power (S), and the reactive power (Q) of the circuit.
2. What are the values of the components R and L?
3. Calculate the value of the compensating capacitance needed to achieve a power factor of 0.95 and inductive, while keeping the active power constant. Also, calculate the current after compensation.
4. Create a qualitative representation of the power triangle and visualize the various currents and phase angles on the oscilloscope before and after compensation.

### Setup initialization <a href="#setup-initialization.2" id="setup-initialization.2"></a>

When the virtual laboratory is launched, the initial settings in the “Network and Transformer” tab under “Fundamental” and “Harmonic” are configured as follows:

a) Set the frequency to 50 Hz.

b) Choose the network as a single-phase network with the phase A voltage of 230 V and no phase shift.

c) Set the transformer to short-circuit mode as it is not used.

d) The circuit breaker is not used; the “Without protection” button is activated.

e) Under the “Harmonic” tab, no harmonics are added. The “A” button is deactivated.

f) Under the “Passive load” tab, choose the “A1 + B1//C1” configuration.

## Before compensation <a href="#a-before-compensation" id="a-before-compensation"></a>

In the first question, you are asked to calculate the power factor cos(φ), the phase angle φ between current and voltage, the apparent power S, and the reactive power Q of the circuit. Then, based on these calculations, you need to determine the values of the components R and L. Compensation will be applied in a subsequent step.

#### **1- The setup**

The requested setup can be performed under the “Passive load” tab:

1. Set impedance Z\_1\_Series to unbalanced mode and choose component A as a  hort circuit, component B as an open circuit (as it is used later), and component C as an RL impedance with the previously calculated values.
2. The other three impedances are balanced circuits with component A in short circuit.

#### **2- Take measurements**

Once the setup is complete, it’s time to take measurements:

1. In the “Network and Transformer” tab, activate the “Power On” button.
2. Open the “Measurements and Calculations” tab and select “Rés U” for measurement 1 and “Rés Z\_1 I” for measurement 2. For both measurements, observe phase A.
3. Examine the signals using the measurements and the “Oscilloscope” tab, and compare the measured phase angle with the theoretical value.

## After Compensation <a href="#b-after-compensation" id="b-after-compensation"></a>

In a second step, it is requested to apply the compensation with the calculated capacitance value. The capacitor is inserted in parallel with the existing circuit.

#### **1- The setup**

The requested setup can be done under the “Passive load” tab:

1. Set the impedance Z\_1\_Series to non-balanced mode and choose component A as a short circuit, component B as a capacitor, and component C as an impedance RL. Use the previously calculated values.
2. The other three impedances are balanced circuits with component A short-circuited.

#### **2- Take measurements**

Once the setup is complete, you need to take the measurements:

1. In the “Network and Transformer” tab, activate the “Power On” button.
2. Open the “Measurements and Calculations” tab and select “Rés U” for measurement 1 and “Rés Z\_1 I” for measurement 2. For both measurements, phase A is observed.
3. Observe the signals using the measurements and in the “Oscilloscope” tab, and compare the measured phase shift after compensation with the theoretical value.

## **Laboratory report**

1. Perform the preparatory activities.
2. Present and comment on the oscillogram for each question.
3. Compare the theoretical values with the measured values in both situations: without and with compensation.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/single-phase-systems/single-phase-rlc-circuit-in-steady-state-power-factor-correction.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.