> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/three-phase-systems/3-phase-balanced-passive-circuit-in-steady-state-with-unbalanced-load-symmetrical-components.md).

# 3-Phase Balanced Passive Circuit in Steady-State with Unbalanced Load, Symmetrical Components

## Objective <a href="#objective.3" id="objective.3"></a>

In the **3-Phase Balanced Passive Circuit in Steady-State with Unbalanced Load, Symmetrical Components, and Neutral Influence** exercise, we will consider a symmetrical three-phase source, connected in a star configuration with a phase voltage of $$U\_{PN} = 230 , \text{V}$$ and a frequency of $$f = 50 ,\text{Hz}$$ , which supplies two symmetrical three-phase circuits. Circuit 1 consists of three resistors $$R\_1 = 60 , \Omega$$ and three inductors $$L = 250 ,\text{mH}$$ connected in a star configuration. Circuit 2 consists of three resistors $$R\_2 = 200 , \Omega$$ connected in a Delta configuration. The diagram is illustrated below:

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FCch7ctQ5NOYX0lzag7GY%2F739964b7-a479-4788-a33b-f2cfb5ed33ee.png?alt=media&amp;token=a855018b-ea4d-4228-b236-e0aa706d2c8f" alt=""><figcaption><p><strong>Figure 4:</strong> Asymmetrical three-phase circuit considered</p></figcaption></figure>

## Preparatory activities <a href="#preparatory-activities.3" id="preparatory-activities.3"></a>

In order to carry out the requested circuit and better understand the fundamentals, theoretical exercises are required. The values of the circuit elements are as follows:

* $$U\_1 = 230 ,\text{V}$$
* The frequency of the source: $$f = 50 ,\text{Hz}$$
* $$Z\_1 = 36 , e^{j10^\circ} , \Omega$$
* $$Z\_2 = 56 , e^{j15^\circ} , \Omega$$
* $$Z\_3 = 112 , e^{j20^\circ} , \Omega$$

1. Calculate the line currents and the homopolar, direct, and inverse currents using the inverse Fortescue matrix. Compare the line currents and the symmetrical components measured in the virtual laboratory with those calculated. Visualize the line currents as well.
2. Calculate the current in the neutral $$I\_N$$ and compare it with the homopolar current  $$I\_h$$ . Visualize the current in the neutral.
3. What happens to the currents of the symmetrical components, namely homopolar, direct, and inverse, when $$Z\_1 = Z\_2 = Z\_3 = 100 , \Omega$$ ? Compare with the result of question 1 as well as with the values obtained from the virtual laboratory.
4. Calculate the apparent, active, and reactive powers using the symmetrical components. Also, compare them with the powers measured in the virtual laboratory.

### Setup initialization <a href="#setup-initialization.2" id="setup-initialization.2"></a>

When the virtual laboratory is launched, the initial settings in the "Network and Transformer" tab under "Fundamental" and "Harmonic" are configured as follows:

1. Set the frequency to 50Hz.
2. Choose the network as a three-phase network with a phase voltage of 230V and no phase shift.
3. Activate the "Phase Inversion" button to obtain results equivalent to the calculations.
4. Set the transformer to short-circuit mode as it is not used.
5. The circuit breaker remains in the initial mode; set to 16A, class 10, and mode Z.
6. Under the "Harmonic" tab, no harmonics are added. Activate the "Équilibrées" button and set phase A to 0V.
7. Under the "Passive load" tab, choose the "Star" configuration.

## Question 1 <a href="#question-1.3" id="question-1.3"></a>

In this exercise, you are required to measure line currents and the homopolar, direct, and indirect currents. The Fortescue transformation is used for this purpose.

#### 1- The setup <a href="#id-1-the-setup.4" id="id-1-the-setup.4"></a>

The requested setup can be achieved under the "Passive load" tab:

1. Activate impedance Z\_1\_Series and choose an RL impedance for each component with the previously calculated values.
2. The other three impedances are balanced circuits with component A in short-circuit mode.

#### 2- Take measurements <a href="#id-2-take-measurements.4" id="id-2-take-measurements.4"></a>

Once the setup is complete, you need to take measurements:

1. In the "Network and Transformer" tab, activate the "Power On" button.
2. Open the "Measurements and Calculations" tab and measure the currents "Rés Z\_1 I" for each phase and observe the magnitudes and phase angles of the currents.
3. Observe the signals using the measurements and the "Oscilloscope" tab.
4. Next, measure the symmetrical components using the Fortescue transformation of the network.
5. Compare the results with your calculations.

## Question 2 <a href="#question-2.3" id="question-2.3"></a>

For question 2, you will observe the neutral current and the homopolar current. The setup remains the same.

### Take measurements <a href="#take-measurements.4" id="take-measurements.4"></a>

1. In the "Network and Transformer" tab, activate the "Power On" button.
2. Open the "Measurements and Calculations" tab and measure the current "Z\_N\_I" of phase A and the homopolar current. Compare the values.
3. Observe the signals using the measurements and the "Oscilloscope" tab. The signals to observe are "Rés Z\_1 U" and "Z\_N\_I."

## Question 3 <a href="#question-3.2" id="question-3.2"></a>

In this exercise, you are asked to make modifications to the circuit and make it symmetric by setting $$Z\_1 = Z\_2 = Z\_3 = 100 , \Omega$$.

### 1- The setup <a href="#id-1-the-setup.5" id="id-1-the-setup.5"></a>

The requested setup can be achieved under the "Passive load" tab:

1. Set impedance Z\_1\_Series in balanced mode and choose component A as an R impedance with a value of $$R = 100 , \Omega$$.
2. The other three impedances are balanced circuits with component A in short-circuit mode.

### 2- Take Measurements <a href="#id-2-take-measurements.5" id="id-2-take-measurements.5"></a>

Once the setup is complete, you need to take the appropriate measurements:

1. In the "Network and Transformer" tab, activate the "Power On" button.
2. Open the "Measurements and Calculations" tab and measure "Z\_N\_I" and "Rés Z\_1 I" for phase A.
3. Observe the signals using the measurements and the "Oscilloscope" tab.
4. Next, measure the symmetrical components using the Fortescue transformation of the network.

## Question 4 <a href="#question-4" id="question-4"></a>

In this exercise, you are asked to measure the powers in the circuit. The setup is the same as in question 1.

### Take measurements <a href="#take-measurements.5" id="take-measurements.5"></a>

1. In the "Network and Transformer" tab, activate the "Power On" button.
2. Open the "Measurements and Calculations" tab and measure the current "Rés Z\_1 I" for each phase.
3. Next, measure the symmetrical components using the Fortescue transformation of the network.

## Laboratory report <a href="#laboratory-report.3" id="laboratory-report.3"></a>

1. Perform the preparatory activities.
2. Present and comment on the oscillogram for each question.
3. Compare the theoretical values with the measured values.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/three-phase-systems/3-phase-balanced-passive-circuit-in-steady-state-with-unbalanced-load-symmetrical-components.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.