> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/three-phase-systems/3-phase-passive-balanced-circuit-in-steady-state-star-delta-configuration.md).

# 3-Phase Passive Balanced Circuit In Steady-State, Star-Delta Configuration

## Objective <a href="#objective.2" id="objective.2"></a>

In this exercise, we will consider a symmetrical three-phase source connected in a star configuration with a phase voltage of $$U\_{PN} = 230,\text{V} \\$$ and a frequency of $$f = 50,\text{Hz} \\$$ . This source will supply power to two symmetrical three-phase setups. Setup 1 consists of three resistors $$R\_1 = 60,\Omega \\$$ and three inductors $$L = 250,\text{mH} \\$$ connected in a star configuration. Setup 2 consists of three resistors $$R\_2 = 200,\Omega$$ connected in a delta (Delta) configuration. The diagram is illustrated below:

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FpsWXzrfH6pQDuUkw7DNg%2Fe12b576f-d004-4047-8063-f6518bab1f93.png?alt=media&amp;token=75a363a7-5e7c-497f-90cd-1791b33a6ec3" alt=""><figcaption><p><strong>Figure 3:</strong> Three-Phase RL load in star and delta configurations</p></figcaption></figure>

## Preparatory activities <a href="#preparatory-activities.2" id="preparatory-activities.2"></a>

To set up the requested circuit and gain a better understanding of the basics, theoretical exercises are required. The values of the circuit elements are as follows:

* $$U\_{\text{line}} = 400,\text{V} \\$$
* Source frequency $$f = 50,\text{Hz} \\$$
* $$R\_1 = 60,\Omega \\$$
* $$L = 250,\text{mH} \\$$
* $$R\_2 = 200,\Omega$$

1. Calculate the line current and visualize and compare the currents using the oscilloscope in the "Virtual Laboratory."
2. Repeat the calculations with a frequency of f = 100 Hz.

### Setup initialization <a href="#setup-initialization.1" id="setup-initialization.1"></a>

When the virtual laboratory is launched, the initial settings in the "Network and Transformer" tab under "Fundamental" and "Harmonic" are configured as follows:

1. Set the frequency to 50Hz.
2. Choose the network as a three-phase network with a phase voltage of 230V and no phase shift.
3. Set the transformer to the short-circuit mode as it is not used.
4. The circuit breaker is not used; the "Without protection" button is activated.
5. Under the "Harmonic" tab, no harmonics are added. The "A" button is deactivated.
6. Under the "Passive load" tab, choose the "Delta" configuration.

## Question 1 <a href="#question-1.2" id="question-1.2"></a>

In this exercise, you are asked to measure the line current of the circuit.

### 1- The setup <a href="#id-1-the-setup.3" id="id-1-the-setup.3"></a>

The requested setup can be performed under the "Passive load" tab as follows:

1. Set the impedance Z\_1\_Series to balanced mode and choose component A as an impedance R with the value $$R = 200,\Omega$$.
2. Set the impedance Z\_2\_Series to balanced mode and choose component A as an impedance RL with the values $$R = 60,\Omega$$ and $$L = 250,\text{mH}$$ .
3. The other two impedances should be set to balanced circuits with component A in short-circuit mode.

### 2- Take measurements <a href="#id-2-take-measurements.3" id="id-2-take-measurements.3"></a>

Once the setup is complete, you need to take the measurements as follows:

1. In the "Network and Transformer" tab, activate the "Power On" button.
2. Open the "Measurements and Calculations" tab and measure the currents "Rés I," "Z\_1 I," and "Z\_2 I" for phase A. Observe the magnitudes and phases (arguments) of these currents.
3. Observe the result when the "Phase Inversion" button is activated and explain what you observe.
4. Use the measurements to observe the signals under the "Oscilloscope" tab.

## Question 2 <a href="#question-2.2" id="question-2.2"></a>

For question 2, you are asked to repeat the previous exercise with a frequency of f = 100 Hz. The setup remains the same.

### Take measurements <a href="#take-measurements.3" id="take-measurements.3"></a>

1. In the "Network and Transformer" tab, under "Fundamental," set the frequency to 50Hz.
2. In the "Network and Transformer" tab, activate the "Power On" button.
3. Open the "Measurements and Calculations" tab and measure the currents "Rés I," "Z\_1 I," and "Z\_2 I" for phase A. Observe the magnitudes and phases (arguments) of these currents.
4. Use the measurements to observe the signals under the "Oscilloscope" tab.

#### Laboratory report <a href="#laboratory-report.2" id="laboratory-report.2"></a>

1. Perform the preparatory activities.
2. Present and comment on the oscillogram for each question.
3. Compare the theoretical values with the measured values.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/three-phase-systems/3-phase-passive-balanced-circuit-in-steady-state-star-delta-configuration.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.