> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/three-phase-systems/3-phase-passive-circuit-in-stead-state-arranges-in-delta-configuration.md).

# 3-Phase Passive Circuit in Stead-State Arranges in Delta Configuration

## Objective <a href="#objective.1" id="objective.1"></a>

In this exercise, we will consider a balanced three-phase load connected in a delta configuration, consisting of a capacitance and a resistance per phase with values of R=100 Ω and C=40 μF. This load is supplied by a symmetrical three-phase network with a line voltage of

and a frequency of 50 Hz. The diagram considered is illustrated below.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FUG57j3YLLS1nGVNE6bBh%2F52fe2611-1d48-45fc-9ac8-ebf65b5dbfd5.png?alt=media&amp;token=73fc6146-68df-4c9f-82e7-99abab65b939" alt=""><figcaption><p><strong>Figure 2:</strong> Symmetrical Three-Phase RC Load Connected in Delta Configuration</p></figcaption></figure>

## Preparatory activities <a href="#preparatory-activities.1" id="preparatory-activities.1"></a>

To create the requested circuit and gain a better understanding of the fundamentals, theoretical exercises are required. The values of the circuit elements are as follows:

* $$U\_{\text{line}} = 400,\text{V} \\$$
* $$f = 50,\text{Hz} \\$$
* $$R = 100,\Omega \\$$
* $$C = 40,\mu\text{F}$$

1. Calculate the current flowing in the three phases. Visualize and compare the currents using the oscilloscope in the virtual lab.
2. Calculate the current flowing in the three lines. Visualize and compare the currents using the oscilloscope in the virtual lab. What observations can be made?
3. Determine the power factor analytically and compare it with the virtual lab. Do the same for the active, reactive, and apparent power supplied by the source.

### Setup initialization <a href="#setup-initialization" id="setup-initialization"></a>

When the virtual lab is launched, the initial settings in the "Network and Transformer" tab under "Fundamental" and "Harmonic" should be adjusted as follows:

1. Set the frequency to 50Hz.
2. Choose the network as a three-phase network with a phase voltage of 230V and no phase shift.
3. Activate the "Phase Inversion" button to obtain results consistent with calculations (following convention).
4. Set the transformer to short-circuit mode as it is not used.
5. The circuit breaker is not used; the "Without protection" button is activated.
6. Under the "Harmonic" tab, no harmonics are added. The "A" button is deactivated.
7. Under the "Passive load" tab, choose the configuration "Delta."

## Question 1 <a href="#question-1.1" id="question-1.1"></a>

In this exercise, you are asked to calculate the current flowing through the three phases.

### 1- The setup <a href="#id-1-the-setup.2" id="id-1-the-setup.2"></a>

The requested setup can be performed under the 'Passive load' tab:

1. Set the Z\_1\_Series impedance to balanced mode and choose component A as an RC impedance with the values $$R = 100,\Omega$$ and $$C = 40,\mu\text{F}$$ .
2. The other three impedances are balanced circuits with component A in short-circuit

### 2- Take measurements <a href="#id-2-take-measurements.2" id="id-2-take-measurements.2"></a>

Once the setup is done, it's time to take measurements:

1. In the "Network and Transformer" tab, activate the "Power On" (Power on) button.
2. Open the "Measurements and Calculations" tab, measure "Z\_1 I" for each phase, and observe the magnitudes and arguments of the currents. Find the transformation to obtain the calculated values.
3. Observe the signals using the measurements and the "Oscilloscope" tab.

## Question 2 <a href="#question-2.1" id="question-2.1"></a>

For question 2, the line currents are requested, and the setup remains the same.

### Take measurements <a href="#take-measurements.1" id="take-measurements.1"></a>

a) In the "Network and Transformer" tab, activate the "Power On" (Power On) button.

b) Open the "Measurements and Calculations" tab and measure "Rés Z\_1 I" for each phase. Observe the magnitudes and arguments of the currents. Find the transformation to obtain the calculated values.

c) Observe the signals using the measurements and the "Oscilloscope" tab.

## Question 3 <a href="#question-3.1" id="question-3.1"></a>

For question 2, the power factor and powers need to be observed. The setup remains the same.

### Take measurements <a href="#take-measurements.2" id="take-measurements.2"></a>

1. In the "Network and Transformer" tab, activate the "Power On" (Power On) button.
2. Open the "Measurements and Calculations" tab and measure P and S for the network. Deduce the reactive power Q.
3. Open the "Measurements and Calculations" tab and measure "Rés I" for phase A and observe the phase shift.
4. Observe the signals using the measurements and the "Oscilloscope" tab.

## Laboratory report <a href="#laboratory-report.1" id="laboratory-report.1"></a>

1. Perform the preparatory activities.
2. Present and comment on the oscillogram for each question.
3. Compare the theoretical values with the measured values.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/fundamentals-of-electrical-engineering/three-phase-systems/3-phase-passive-circuit-in-stead-state-arranges-in-delta-configuration.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.