> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/exercises/part-1-three-phase-thyristor-bridge-rectifier-resistive-load.md).

# Part 1 - Three-phase Thyristor Bridge Rectifier - Resistive Load

## Varying firing angle <a href="#exercise-1-varying-firing-angle" id="exercise-1-varying-firing-angle"></a>

* In the panel, choose under **Pre-Selected**: Three Phase: Varying Resistive Load, and set the AC-source voltage to 140 V.
* Keep the resistance R to 16.7 ohms.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FMcM5BWPmSTJ0hax6mDXu%2Fimage.png?alt=media&amp;token=948824bd-25e5-42d5-96f5-9852b0561d3d" alt=""><figcaption><p><strong>Figure 22</strong>: Three-Phase Thyristor Bridge Rectifier Panel with an AC-source amplitude of 140 V</p></figcaption></figure>

### Effect of Varying Firing Angle

Vary the firing angle from zero to 120 degrees and fill out table 20 below.

<table><thead><tr><th>Firing angle (Deg)</th><th width="70.39996337890625">0</th><th width="69.5999755859375">20</th><th width="70.39996337890625">40</th><th width="69.5999755859375">60</th><th width="70.4000244140625">80</th><th width="70.39996337890625">90</th><th width="69.60003662109375">110</th><th width="69.5999755859375">120</th></tr></thead><tbody><tr><td><strong>Mean of load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Mean of load current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>AC-source power (W)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Load power (W)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>THD of AC-source Current (%)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr></tbody></table>

1. Plot on the same graph:
   * the firing angle versus the average load voltage based on table 20 above
   * the firing angle versus the average load voltage based on [equation (18)](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/operating-principle.md#order-of-conducting-thyristors-for-a-firing-angle-of-0-when-the-load-is-resistive)
2. Do the two plots match one another?\
   Explain your observation.
3. What is the firing angle for which the load power vanishes to zero?
4. How does the increasing firing angle impact the THD of the AC-source current?

## Changing resistive load <a href="#exercise-2-changing-resistive-load" id="exercise-2-changing-resistive-load"></a>

1. Set the AC-source amplitude to 140 V.\
   Change the resistance R to 25 ohms.
2. Fill out table below for different values of the firing angle.

<table><thead><tr><th>Firing angle (Deg)</th><th width="70.4000244140625">0</th><th width="69.5999755859375">20</th><th width="69.5999755859375">40</th><th width="69.59991455078125">60</th><th width="70.4000244140625">80</th><th width="72">90</th><th width="70.4000244140625">110</th><th width="70.4000244140625">120</th></tr></thead><tbody><tr><td><strong>Mean of load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td></td></tr><tr><td><strong>Mean of load current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td></td></tr><tr><td><strong>AC-source power (W)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td></td></tr><tr><td><strong>Load power (W)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td></td></tr><tr><td><strong>THD of AC-source Current (%)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td></td></tr></tbody></table>

3. How does the change of resistance value impact the results?\ <i class="fa-lightbulb-cfl-on" style="color:$info;">:lightbulb-cfl-on:</i> *C*ompare results of both tables.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/exercises/part-1-three-phase-thyristor-bridge-rectifier-resistive-load.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.