> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/operating-principle.md).

# Operating Principle

## Introduction

Figure 19 shows the diagram of a three-phase thyristor bridge rectifier.\
Observe that the circuit topology is the same as that of a [power diode three-phase full-wave rectifier](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-diode-bridge-rectifier/operating-principle.md), except that all diodes are replaced with thyristors.\
Using thyristors instead of diodes in a three-phase full-wave rectifier allows the beginning of the conduction interval of each thyristor to be delayed, and thereby, the values of the average (DC) voltage and current at the rectifier output to be varied.\
The operation of the thyristor three-phase rectifier is studied in this laboratory.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F8zRVa5OV9CswpmjOztR0%2Fimage.png?alt=media&amp;token=1142a08d-4a58-4ced-8a8d-d7dfdfd4554e" alt=""><figcaption><p><strong>Figure 19</strong>: Three-phase Thyristor-based Rectifier</p></figcaption></figure>

The operation of a power diode three-phase full-wave rectifier can be reproduced in a thyristor three-phase bridge by firing each thyristor at the same instant as the corresponding diode in a three-phase full-wave rectifier naturally enters into conduction.\
This is achieved by using a firing angle (*α*) of 0° (i.e., without delaying the conduction of the thyristors).

### Order of conducting thyristors for a firing angle of 0° when the load is resistive

To generate firing signals that are properly synchronized with the ac power source voltages, the thyristor firing circuit samples one of the line-to-line voltages (e.g., line-to-line voltage *v*<sub>*AB*</sub> in figure 20 below).\
Since the firing angle is set to 0°:

* Thyristor T<sub>1</sub> is fired at phase angle 60<sup>o</sup> of line-to-line voltage v<sub>AB</sub> (or at phase angle 30<sup>o</sup> of phase voltage *v*<sub>*AN*</sub>). This turns thyristor T<sub>5</sub>
* 120<sup>o</sup> later, thyristor T<sub>3</sub> is fired while thyristor T<sub>1</sub> turns off.
* 120<sup>o</sup> later, thyristor T<sub>5</sub> is fired while thyristor T<sub>3</sub> turns off.

Also, the complementary thyristors T<sub>2</sub>, T<sub>4</sub>, and T<sub>6</sub> are fired 180<sup>o</sup> later than thyristors T1, T3, and T5. Therefore,

* Thyristor T<sub>2</sub> is fired at phase angle 240<sup>o</sup> of line-to-line voltage v<sub>AB</sub> (or at phase angle 210<sup>o</sup> of phase voltage *v*<sub>*AN*</sub>). This turns thyristor T<sub>6</sub>
* 120<sup>o</sup> later, thyristor T<sub>4</sub> is fired while thyristor T<sub>2</sub> turns off.
* 120<sup>o</sup> later, thyristor T<sub>6</sub> is fired while thyristor T<sub>4</sub> turns off.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F7gGCR4NIJHqvU1AwvGx7%2Fimage.png?alt=media&amp;token=dd3ee473-569d-4d72-b38d-1778793c60d9" alt=""><figcaption><p><em><strong>Figure 20</strong>: Waveforms of voltages and thyristor firing signals for a firing α angle set to 0</em>°</p></figcaption></figure>

The firing sequence previously described repeats over and over.\
The pulses in each firing signal have a duration of 120°, which corresponds to the conduction interval of each diode in a three-phase full-wave diode bridge rectifier.

Consequently, the thyristors conduct current by pairs, one after the other, during equal intervals of 60, as presented in table below.

<table data-search="false"><thead><tr><th>Angular Interval
Phase Voltage VAN</th><th>Line-to-line Voltage VAB</th><th>Conducting Thyristors</th></tr></thead><tbody><tr><td>30<sup>o</sup> – 90<sup>o</sup></td><td>60<sup>o</sup> – 120<sup>o</sup></td><td>T<sub>1</sub> and T<sub>4</sub></td></tr><tr><td>90<sup>o</sup> – 150<sup>o</sup></td><td>120<sup>o</sup> – 180<sup>o</sup></td><td>T<sub>1</sub> and T<sub>6</sub></td></tr><tr><td>150<sup>o</sup> – 210<sup>o</sup></td><td>180<sup>o</sup> – 240<sup>o</sup></td><td>T<sub>3</sub> and T<sub>6</sub></td></tr><tr><td>210<sup>o</sup> – 270<sup>o</sup></td><td>240<sup>o</sup> – 300<sup>o</sup></td><td>T<sub>3</sub> and T<sub>2</sub></td></tr><tr><td>270<sup>o</sup> – 330<sup>o</sup></td><td>300<sup>o</sup> – 0<sup>o</sup></td><td>T<sub>5</sub> and T<sub>2</sub></td></tr><tr><td>330<sup>o</sup> – 30<sup>o</sup></td><td>0<sup>o</sup> – 60<sup>o</sup></td><td>T<sub>5</sub> and T<sub>4</sub></td></tr></tbody></table>

The average output voltage in the controlled three-phase bridge rectifier is:

$$
\left\langle V\_s(t)\right\rangle=\frac{3 \cdot \sqrt{3} \cdot \sqrt{2}}{\pi}\cdot V\_e \cos (\alpha)=\frac{3 \cdot \sqrt{3}}{\pi} \cdot V\_m \cos (\alpha) \qquad\text{(18)}
$$

From (18), one can see that the amount of power supplied to the load can be varied by changing the firing angle of the thyristors.\
The values of the DC current and voltage, and thus the power supplied to the load, are maximum when the firing angle is 0°.\
When the firing angle is increased, the firing pulses for each thyristor are delayed, which reduces the average values of the DC current and voltage at the DC side of the bridge, and thus, the amount of power supplied to the load.

The capability to change the amount of power to the load, by changing the firing angle of the thyristors, represents a major advantage of the thyristor three-phase bridge over the three-phase diode bridge rectifier.

{% hint style="info" %}
Equation (18) is valid as long as the current flow in the thyristor bridge rectifier is continuous, which means that there are no time intervals during which the current flow is zero.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/operating-principle.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.