> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/panels-overview.md).

# Panels Overview

## Understand the panels

The **Three-phase Thyristor Bridge Rectifier** model file, located in the folder **OP1130 - Power Electronics Courseware,** is **PE\_TreePhaseThyristorRectifier-version.zip**

When starting the demo, the panel in figure 21 appears first with the default settings.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FUlLhO1xPnWFer4R1M9Dz%2Fimage.png?alt=media&amp;token=47f69013-cb81-4e43-94e2-a4fd486130e2" alt=""><figcaption><p><strong>Figure 21</strong>: Start-Up Panel of the Three-Phase Thyristor Bridge Rectifier Laboratory</p></figcaption></figure>

For operation of the three-phase thyristor bridge rectifier panel, the student can [**refer to the panel operation of the single-phase diode bridge rectifier**](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/single-phase-diode-bridge-rectifier/panels-overview.md), because the panels of both models are very similar.\
The differences in content of scopes, control parameters and buttons, and contents of displays are presented inthe following tables.

### Control parameters

<table><thead><tr><th>Control Parameters</th><th width="149.79998779296875">Default Value</th><th width="149.59686279296875">Interval of Variation</th></tr></thead><tbody><tr><td><strong>AC Source Voltage (V)</strong></td><td>120</td><td>[0; 200]</td></tr><tr><td><strong>Firing Angle (Deg)</strong></td><td>0</td><td>0; 120]</td></tr><tr><td><strong>AC Source Frequency (Hz)</strong></td><td>60</td><td>50 or 60</td></tr></tbody></table>

### Control buttons and LED fuse indicators

<table data-search="false"><thead><tr><th width="149.79998779296875">Buttons &#x26; Led</th><th width="99.79998779296875"></th><th>Associated Functions</th></tr></thead><tbody><tr><td><strong>Trigger</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FGNPhcs0sHBS7Zh0caL2s%2Fimage.png?alt=media&amp;token=d80c4343-3028-4494-aaa5-ba82e1c3e036" alt=""></td><td>The waveforms are not triggered. They “move”.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FzcDScx6EazmzWi4w1IuW%2Fimage.png?alt=media&amp;token=08d267ce-f665-4bb5-890e-c1933ab7ce9f" alt=""></td><td>The waveforms are triggered with respect to a reference signal.</td></tr><tr><td><strong>Data Acq.</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FGNPhcs0sHBS7Zh0caL2s%2Fimage.png?alt=media&amp;token=d80c4343-3028-4494-aaa5-ba82e1c3e036" alt=""></td><td>Data acquisition is disabled.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FzcDScx6EazmzWi4w1IuW%2Fimage.png?alt=media&amp;token=08d267ce-f665-4bb5-890e-c1933ab7ce9f" alt=""></td><td>Data acquisition is enabled and allows to record .mat files for offline studies, in particular harmonic analysis.</td></tr><tr><td><strong>Fuse</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FufLjD7C7DrroYd7lWCeW%2Fimage.png?alt=media&amp;token=110185b6-9735-44f2-960a-f9fe284c02b7" alt=""></td><td>The protection fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FXMiLDY930zdIxkjo95dF%2Fimage.png?alt=media&amp;token=9aa49fe8-ce8d-4e15-a037-24bb1e2c66c2" alt=""></td><td>The protection fuse is intact.</td></tr><tr><td><strong>HELP/BACK</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FMdwKyVPMEEsxUFycsDRI%2Fimage.png?alt=media&amp;token=e9f43ea1-0735-4598-81a6-034f8757d907" alt=""></td><td>Open the Help page, where a summary of three-phase thyristor bridge rectifier is shown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FJwJUuGkMex2i9kiZGi1p%2Fimage.png?alt=media&amp;token=4334f160-0b45-4039-bb46-cc19a318c78d" alt=""></td><td>Close the Help page and go back to the simulations.</td></tr><tr><td><strong>Switch</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F6ReQZ0a25sc8DJXSgsFv%2Fimage.png?alt=media&amp;token=a34b8db6-781f-416e-a9ee-f94618a06c7f" alt=""></td><td>AC Source frequency, 50 or 60 Hz.</td></tr></tbody></table>

### Scopes and displayed waveforms

<table><thead><tr><th width="150">Scope</th><th>Content of Scopes &#x26; Displayed Waveforms</th></tr></thead><tbody><tr><td><strong>Scope</strong><sub><strong>11</strong></sub></td><td>AC-source voltage <em>v</em><sub><em>AN</em></sub>, load voltage, and thyristor T<sub>1</sub> voltage</td></tr><tr><td><strong>Scope</strong><sub><strong>21</strong></sub></td><td>AC-source voltage <em>v</em><sub><em>AN</em></sub><em>,</em> AC-source current <em>i</em><sub><em>A</em></sub><em>,</em> Fundamental of current <em>i</em><sub><em>A</em></sub></td></tr><tr><td><strong>Scope</strong><sub><strong>12</strong></sub></td><td>AC-source current <em>i</em><sub><em>A</em></sub>, load current, and thyristor T<sub>1</sub> current</td></tr><tr><td><strong>Scope</strong><sub><strong>22</strong></sub></td><td>AC-source current <em>i</em><sub><em>A</em>,</sub> AC-source current <em>i</em><sub><em>B</em></sub><em>,</em> AC-source current <em>i</em><sub><em>C</em></sub></td></tr></tbody></table>

Six displays are shown on the panel. They are located below the scopes.\
From left to right they are identified as Display<sub>1</sub>, Display<sub>2</sub>, Display<sub>3</sub>, Display<sub>4</sub>, Display<sub>5</sub>, and Display<sub>6</sub>.

<table data-search="false"><thead><tr><th width="150">Display</th><th>Content of Displays</th></tr></thead><tbody><tr><td><strong>Display</strong><sub><strong>1</strong></sub></td><td>AC-source power (W)</td></tr><tr><td><strong>Display</strong><sub><strong>2</strong></sub></td><td>Load power (W)</td></tr><tr><td><strong>Display</strong><sub><strong>3</strong></sub></td><td>Fundamental of AC-source current (A)</td></tr><tr><td><strong>Display</strong><sub><strong>4</strong></sub></td><td>THD of AC-source current (%)</td></tr><tr><td><strong>Display</strong><sub><strong>5</strong></sub></td><td>Mean of load current (A)</td></tr><tr><td><strong>Display</strong><sub><strong>6</strong></sub></td><td>Mean of load voltage (V)</td></tr></tbody></table>

{% hint style="info" %}
The “Save File” under Scope Parameters allows the student to give different file names for data acquisition.\
It is possible to save up to eleven .mat files with the name “FileSavedcurrents\_X (where X can be anywhere from 0 to 10).\
The student can give X values via the “Save File”, and press “Data Acq.” for acquiring data.\
The data acquired can be used for offline harmonic studies.\
The saved data are in the following folder: *C:\OPAL-RT\TestDrive\v2.9.0.16\Models\ThreePhase\_ThyristorRectifier\threephase\_thyristorrectifier\_sm\_master\OpNTtarget*
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/ac-to-dc-rectifiers/three-phase-thyristor-bridge-rectifier/panels-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.