> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/single-phase-two-level-inverter/circuit-description.md).

# Circuit Description

## Converter Topology <a href="#id-3.1-converter-topology" id="id-3.1-converter-topology"></a>

The Single-Phase Two-Level converter is shown in figure below:

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fw8gHVHTmiNWA8RowCkFc%2Fimage.png?alt=media&amp;token=301c79e6-0494-4f48-86b1-7748077c7524" alt="" width="480"><figcaption><p><strong>Figure 2</strong>: Single-Phase Two-Level Inverter</p></figcaption></figure>

The single-phase two-level inverter has four IGBT/diode switches (named as *S*<sub>*1*</sub> to *S*<sub>*4*</sub>) with two switches per arm.\
The inverter has two inputs: (i) positive and (ii) negative terminals of the DC voltage source.\
It also has two outputs A and B which feed the load.

## Control of the switches and PWM generation

The control of the switches of the first arm, that is displayed in figure 3, is explained below. The same control is to be applied for arm two with a phase-shift of +180<sup>o</sup>.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FJ86EgQR0Jig8svM3TzKA%2Fimage.png?alt=media&amp;token=7d116cab-6abe-4677-9cc9-0ec23450e550" alt="" width="300"><figcaption><p><strong>Figure 3</strong>: First Arm of the Single-Phase Two-Level Inverter</p></figcaption></figure>

The **PWM train** is generated using the method of intersection between the reference signal that is a sine-wave signal oscillating at either 60 Hz or 50 Hz, and one triangular carrier oscillating at the switching frequency. The reason behind having one carrier (instead of two) is the fact that each arm contains two IGBTs (instead of four IGBTs, as is the case in a three-level inverter). The comparison between the reference signal for the first arm and the carrier is illustrated in figure 4.

The switching frequency is a user-controlled parameter, varying between 900 Hz and 3000 Hz. It is up to the user to select switching frequency values that are multiples of 60 or 50 depending on whether 60 Hz or 50 Hz is chosen as a reference frequency.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F56A6dEMad4Mod9Ky3td4%2Fimage.png?alt=media&amp;token=3f1e45d0-018c-46f7-9d0c-827333634313" alt=""><figcaption><p><strong>Figure 4</strong>: PWM Generation for the First Arm of the Single-Phase Two-Level Inverter</p></figcaption></figure>

From figure 4, the student can see that switches S1 and S2 are complementary, which means that both of the switches in the same leg cannot be turned ON at the same time, as the input DC voltage would be in short-circuit, thus violating the Kirchhoff’s voltage law (KVL).

### Switching states in the single-phase two-level inverter

Therefore, we have:

$$
S\_1+S\_2=1 \\
S\_3+S\_4=1
$$

<table data-header-hidden><thead><tr><th width="80.00006103515625" align="center"></th><th width="80" align="center"></th><th width="80" align="center"></th><th width="80.4000244140625" align="center"></th><th width="79.59674072265625" align="center"></th></tr></thead><tbody><tr><td align="center"><strong>S</strong><sub><strong>1</strong></sub></td><td align="center"><strong>S</strong><sub><strong>2</strong></sub></td><td align="center"><strong>S</strong><sub><strong>3</strong></sub></td><td align="center"><strong>S</strong><sub><strong>4</strong></sub></td><td align="center"><em><strong>V</strong></em><sub><em><strong>AB</strong></em></sub></td></tr><tr><td align="center">1</td><td align="center">0</td><td align="center">0</td><td align="center">1</td><td align="center"><em>V</em><sub><em>dc</em></sub></td></tr><tr><td align="center">0</td><td align="center">1</td><td align="center">1</td><td align="center">0</td><td align="center"><em>-V</em><sub><em>dc</em></sub></td></tr><tr><td align="center">1</td><td align="center">0</td><td align="center">1</td><td align="center">0</td><td align="center"><em>0</em></td></tr><tr><td align="center">0</td><td align="center">1</td><td align="center">0</td><td align="center">1</td><td align="center"><em>0</em></td></tr></tbody></table>

The table above shows the switching state of the chosen PWM generation and the corresponding voltage levels.\
It can be observed from the table that when the two top or the two bottom devices are turned on, the output voltage is zero.

{% hint style="info" %}
*V*<sub>*AB*</sub> is the inverter output voltage.
{% endhint %}

## Load and filter <a href="#id-3.3-load-and-filter" id="id-3.3-load-and-filter"></a>

The load and filter are show in figure below.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FBQFLsRwcPTnV6VfXCm5N%2Fimage.png?alt=media&amp;token=31cf7afa-49b3-4db6-84fb-ddc1d3b1eaf2" alt=""><figcaption><p><strong>Figure 5</strong>: Load and Filter in the Single-Phase Two-Level Inverter</p></figcaption></figure>

### Load <a href="#id-3.2.1-load" id="id-3.2.1-load"></a>

The load is composed of the combination in series of (i) a constant resistance, (ii) a constant inductance and (iii) a controllable AC-source.\
Therefore, the student controls the three parameters of the AC-source, namely, the amplitude, frequency, and phase-shift.\
Exercises showing the impact of changing these parameters will be covered thoroughly.

### Filter <a href="#id-3.3.2-filter" id="id-3.3.2-filter"></a>

The filter is composed of inductance in series with the load, and the capacitance. The filter inductance value corresponds to 10% of the load inductance.

## Inverter parameters and nameplate <a href="#id-3.4-inverter-parameters-and-nameplate" id="id-3.4-inverter-parameters-and-nameplate"></a>

The single-phase two-level parameters and its nameplate are shown in the table below.

<table data-search="false"><thead><tr><th width="140">Parameters</th><th width="140.20001220703125">Value</th><th>Description</th></tr></thead><tbody><tr><td><span class="math">F_{ref}</span></td><td>50/60 Hz</td><td>Reference frequency for PWM generation</td></tr><tr><td><span class="math">R_L</span></td><td>0.43 Ω</td><td>Constant load resistance</td></tr><tr><td><span class="math">L_L</span></td><td>3.02 mH</td><td>Constant load inductance</td></tr><tr><td><span class="math">P_N</span></td><td>5000 W</td><td>Nominal Power of the inverter</td></tr><tr><td><span class="math">V_{out}</span></td><td>[45 91.8] V</td><td>Output RMS voltage of the inverter</td></tr><tr><td><span class="math">L_{out}</span></td><td>[14 88] A</td><td>Output RMS current of the inverter</td></tr><tr><td><span class="math">L_{F}</span></td><td>0.302 mH</td><td>Inductance of the filter (10% of the load inductance)</td></tr><tr><td><span class="math">C_F</span></td><td>699 µF</td><td>Capacitance of the filter</td></tr></tbody></table>

## Measurements <a href="#inlineextension-3.5-measurements" id="inlineextension-3.5-measurements"></a>

Three spots were considered for current, voltage and power measurements, as shown in figure 6 below.

* The DC bus at the input of the converter bridge
* The AC bus at the output of the converter bridge
* The input of the load

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FZsa78XMVaovkR0rWXSnh%2Fimage.png?alt=media&amp;token=658500e9-8885-4b50-a245-02ee50f35551" alt=""><figcaption><p><strong>Figure 6</strong>: Measurements in the Single-Phase Two-Level Inverter</p></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/single-phase-two-level-inverter/circuit-description.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.