> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/single-phase-two-level-inverter/exercises/lc-filter-activated.md).

# LC Filter Activated

## Change PWM frequency <a href="#id-5.2.1-changing-pwm-frequency" id="id-5.2.1-changing-pwm-frequency"></a>

This exercise is intended to change the PWM frequency and observe its impact on the waveforms, THD, and the power flow. For that, keep all the parameters unchanged except for the slider: **PWM Frequency (Hz)**.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FfmajMWBZler0a2Y84pmP%2Fimage.png?alt=media&amp;token=5ed41e94-d83d-4dd8-93ee-6ac8e85f9e41" alt=""><figcaption><p><strong>Figure 12</strong>: Varying PWM Frequency</p></figcaption></figure>

1. Apply the PWM frequency values of the first column of this table with LC Filter ON, observe the waveforms, read the displays, and fill out below.

| PWM Frequency (Hz) | Power1 / Display1 | Power2 / Display2 | Power3 / Display3 |
| ------------------ | ----------------- | ----------------- | ----------------- |
| **900**            |                   |                   |                   |
| **1500**           |                   |                   |                   |
| **1800**           |                   |                   |                   |
| **2400**           |                   |                   |                   |
| **3000**           |                   |                   |                   |

* Disable the **Connect Filter button** (LC Filter OF&#x46;*)* and redo the same exercise.

| PWM Frequency (Hz) | Power1 / Display1 | Power2 / Display2 | Power3 / Display3 |
| ------------------ | ----------------- | ----------------- | ----------------- |
| **900**            |                   |                   |                   |
| **1500**           |                   |                   |                   |
| **1800**           |                   |                   |                   |
| **2400**           |                   |                   |                   |
| **3000**           |                   |                   |                   |

3. How does the change of PWM Frequency impact the THD of load and inverter currents?\ <i class="fa-lightbulb-cfl-on">:lightbulb-cfl-on:</i>  Please observe the values of Display<sub>6</sub> and Display<sub>7</sub>.

## Change AC-source amplitude <a href="#id-5.2.2-changing-ac-source-amplitude" id="id-5.2.2-changing-ac-source-amplitude"></a>

This exercise is intended to show the impact of changing the amplitude of the AC source and to observe the source current and the power flow. Using the slider Amplitude (V), do the following:

1. Increase the value of the amplitude to 75 V and observe the waveforms and the power flow.<br>

   <figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FGy2LziXxruCmCmJ5YeLy%2Fimage.png?alt=media&amp;token=d81c01ca-6c74-46d4-ae16-1897c27e0998" alt=""><figcaption><p><em><strong>Figure 13</strong>: Varying AC-source Amplitude to 75 V</em></p></figcaption></figure>
2. Increase the value of the amplitude to 90 V and redo the same observations.

   <figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FPWUBk8eUvLLwaL15eia0%2Fimage.png?alt=media&amp;token=42ec2051-de33-466d-9b94-3942d98557aa" alt=""><figcaption><p><strong>Figure 14</strong>: Varying AC-source Amplitude to 90 V</p></figcaption></figure>
3. Determine the amplitude at which the power flow vanishes.

## Change AC-source phase-shift <a href="#id-5.2.3-changing-ac-source-phase-shift" id="id-5.2.3-changing-ac-source-phase-shift"></a>

This exercise is a repetition of the [**first inverter mode exercise**](https://www.opal-rt.com/pages/xC9ula5u5e5nLYpE1HZQ#id-5.2.1-changing-pwm-frequency) except that the LC filter is ON.

1. Repeat the same steps as before.<br>

   <figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FFaUuE6NcBoTgHKIYVnhp%2Fimage.png?alt=media&amp;token=d5909e04-6c11-4c15-bfcc-cd71d031e2ed" alt=""><figcaption><p><strong>Figure 15</strong>: Varying AC-source Phase-Shift; Load More Inductive and LC Filter On</p></figcaption></figure>

   <figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FprZw5ToPekdCDObhqYeO%2Fimage.png?alt=media&amp;token=d103db37-1de7-49df-bf66-d59b4fbdc8bf" alt=""><figcaption><p><strong>Figure 16</strong>: Varying AC-source Phase-Shift; Load More Capacitive and LC Filter On</p></figcaption></figure>
2. What difference do you observe in terms of power flow between Phase-Shift of 60 and -70?


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/single-phase-two-level-inverter/exercises/lc-filter-activated.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.