> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/three-phase-two-level-inverter/circuit-description.md).

# Circuit Description

## Converter topology <a href="#id-7.1-converter-topology" id="id-7.1-converter-topology"></a>

The Three-Phase Two-Level converter is shown in following figure.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FgjSg96LruZPlYWAzvZoS%2Fimage.png?alt=media&amp;token=489f760c-f943-40d4-972a-f84ff9ea51a6" alt=""><figcaption><p><strong>Figure 18</strong>: Three-Phase Two-Level Inverter</p></figcaption></figure>

The three-phase two-level inverter has six IGBT/diode switches (named as *S*<sub>*1*</sub> to *S*<sub>*6*</sub>) with two switches per phase.\
The inverter has two inputs: (i) positive and (ii) negative terminals of the DC voltage source. It also has three outputs A, B and C, which feed the three-phase load.

## Control of the switches & PWM generation <a href="#id-7.2-control-of-the-switches-and-pwm-generation" id="id-7.2-control-of-the-switches-and-pwm-generation"></a>

The control of the switches in the first arm, shown in Figure 19, is explained below.

The same control strategy is applied to arms 2 and 3, with phase shifts of −120° and +120°, respectively.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FqxKzp0EJjn2HpHcLV5xu%2Fimage.png?alt=media&amp;token=fbf007de-33a1-4b43-9618-d321144c3592" alt=""><figcaption><p><strong>Figure 19</strong>: First Arm of the Three-Phase Two-Level Inverter</p></figcaption></figure>

The PWM train is generated using the method of intersection between the reference signal that is a sine-wave signal oscillating at either 60 Hz or 50 Hz, and one triangular carrier oscillating at the switching frequency.\
The reason behind having one carrier (instead of two) is the fact that each arm contains two IGBTs (instead of four IGBTs, as is the case in a three-level inverter).

The comparison between the reference signal for the first arm and the carrier is illustrated in te following figure.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F0xT9Dq5HKZxwmJB1AWhR%2Fimage.png?alt=media&amp;token=1c73e94c-c903-4f19-97ba-c29a8bed38bd" alt=""><figcaption><p><strong>Figure 20:</strong> PWM Generation for the First Arm of the Three-Phase Two-Level Inverter</p></figcaption></figure>

The switching frequency is a user-controlled parameter, varying between 900 Hz and 3000 Hz. It is up to the user to select switching frequency values that are a multiple of 60 or 50 depending on if 60 Hz or 50 Hz is chosen as a reference frequency.

From figure 20, the student can see that switches S1 and S2 are complementary, which means that both of the switches in the same leg cannot be turned ON at the same time,\
as the input DC voltage would be in short-circuit, thus violating the Kirchhoff’s voltage law (KVL).\
Therefore, we have:

$$
S\_1+S\_2=1 \\\[8pt]
S\_3+S\_4=1 \\\[8pt]
S\_5+S\_6=1
$$

<table data-header-hidden data-search="false"><thead><tr><th width="80"></th><th width="80"></th><th width="80"></th><th width="80"></th><th width="80"></th><th width="79.996826171875"></th></tr></thead><tbody><tr><td><strong>S</strong><sub><strong>1</strong></sub></td><td><strong>S</strong><sub><strong>2</strong></sub></td><td><strong>S</strong><sub><strong>5</strong></sub></td><td><em><strong>V</strong></em><sub><em><strong>AB</strong></em></sub></td><td><em><strong>V</strong></em><sub><em><strong>BC</strong></em></sub></td><td><em><strong>V</strong></em><sub><em><strong>CA</strong></em></sub></td></tr><tr><td><strong>0</strong></td><td><strong>0</strong></td><td><strong>0</strong></td><td><strong>0</strong></td><td><strong>0</strong></td><td><strong>0</strong></td></tr><tr><td>0</td><td>0</td><td>1</td><td>0</td><td><em>-V</em><sub><em>dc</em></sub></td><td><em>-V</em><sub><em>dc</em></sub></td></tr><tr><td>0</td><td>1</td><td>0</td><td><em>-V</em><sub><em>dc</em></sub></td><td><em>V</em><sub><em>dc</em></sub></td><td>0</td></tr><tr><td>0</td><td>1</td><td>1</td><td><em>-V</em><sub><em>dc</em></sub></td><td>0</td><td><em>V</em><sub><em>dc</em></sub></td></tr><tr><td>1</td><td>0</td><td>0</td><td><em>V</em><sub><em>dc</em></sub></td><td>0</td><td><em>-V</em><sub><em>dc</em></sub></td></tr><tr><td>1</td><td>0</td><td>1</td><td><em>V</em><sub><em>dc</em></sub></td><td><em>-V</em><sub><em>dc</em></sub></td><td>0</td></tr><tr><td>1</td><td>1</td><td>0</td><td>0</td><td><em>V</em><sub><em>dc</em></sub></td><td><em>-V</em><sub><em>dc</em></sub></td></tr><tr><td><strong>1</strong></td><td><strong>1</strong></td><td><strong>1</strong></td><td><strong>0</strong></td><td><strong>0</strong></td><td><strong>0</strong></td></tr></tbody></table>

***Table 11**: The Switching States in a Three-Phase Two-Level Inverter*

Of the eight switching states, as presented in table 11, two of them produce zero AC line voltage at the output.\
In this case, the ac line currents freewheel through either the upper or lower components.\
The remaining states produce no zero ac output line voltages.\
In order to generate a given voltage waveform, the inverter switches from one state to another.\
Thus, the resulting AC output line voltages (*V*<sub>*AB*</sub>, *V*<sub>*BC*</sub> and *V*<sub>*CA*</sub>) consist of discrete values of voltages, which are -V<sub>dc,</sub> 0, and V<sub>dc.</sub>

The selection of the states in order to generate the given waveform is done by a modulation technique that ensures the use of only the valid states.

## Load and filter <a href="#id-7.3-load-and-filter" id="id-7.3-load-and-filter"></a>

The load and filter are given in figure 21:

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FPyuXjykM2Xp609JUYp0n%2Fimage.png?alt=media&amp;token=ab680390-04a8-4a6a-acc2-9e4d96acc328" alt=""><figcaption><p><strong>Figure 21</strong>: Load and Filter in the Three-Phase Two-Level Inverter</p></figcaption></figure>

### Load <a href="#id-7.3.1-load" id="id-7.3.1-load"></a>

The load is composed of the combination in series of (i) a constant resistance, (ii) a constant inductance and (iii) a controllable three-phase AC-source.\
Therefore, the student controls the three parameters of the AC-source, namely, the amplitude, frequency, and phase-shift.\
In [exercises](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/three-phase-two-level-inverter/exercises/inverter-mode.md) showing the impact of changing these parameters will be covered thoroughly.

### Filter <a href="#id-7.3.1-filter" id="id-7.3.1-filter"></a>

The filter is composed of inductances in series with the load, while the capacitances are mounted in delta configuration between phases.\
The filter inductance value corresponds to 10% of the load inductance.\
The value of the capacitance will be computed in an exercise, later, to ensure a cut-off frequency of 600 Hz, which represents 10x the reference frequency (60Hz).

Note that the capacitors can be connected or disconnected; [exercises](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/three-phase-two-level-inverter/exercises/lc-filter-activated.md) covering this matter will be given too.

## Inverter parameters and nameplate <a href="#id-7.4-inverter-parameters-and-nameplate" id="id-7.4-inverter-parameters-and-nameplate"></a>

The three-phase two-level parameters and its nameplate are shown in this table.

<table data-search="false"><thead><tr><th width="130">Parameters</th><th width="129.79998779296875">Value</th><th>Description</th></tr></thead><tbody><tr><td><span class="math">F_{ref}</span></td><td>50/60 Hz</td><td>Reference frequency for PWM generation</td></tr><tr><td><span class="math">R_L</span></td><td>0.43 Ω</td><td>Line-Neutral Resistance</td></tr><tr><td><span class="math">L_L</span></td><td>3.02 mH</td><td>Line-Neutral Inductance</td></tr><tr><td><span class="math">P_N</span></td><td>5000 W</td><td>Nominal Power of the inverter</td></tr><tr><td><span class="math">V_{out}</span></td><td>[40.5 84.8] V</td><td>Line-to-line output RMS voltage of the inverter</td></tr><tr><td><span class="math">I_{out}</span></td><td>[3.5 48] A</td><td>Output RMS current of the inverter</td></tr><tr><td><span class="math">L_F</span></td><td>0.302 mH</td><td>Line-Neutral Inductance of the filter (10% of the load inductance)</td></tr><tr><td><span class="math">C_F</span></td><td>See Ex. 9.1</td><td>Line-Neutral Capacitance of the filter</td></tr></tbody></table>

## Measurements <a href="#inlineextension-7.5-measurements" id="inlineextension-7.5-measurements"></a>

Three spots were considered for current, voltage and power measurements, as shown in figure 22:

* The DC bus at the input of the converter bridge.
* The AC bus at the output of the converter bridge.
* The input of the load.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FXRdgcyyfqiS9pTxDNM8I%2Fimage.png?alt=media&amp;token=abea4a18-8b04-4364-8661-9c289cb3e161" alt=""><figcaption><p><strong>Figure 22</strong>: Measurements</p></figcaption></figure>

It is worth noticing that for the three-phase power measurements, i.e., at the second and third spot, a transformation is required first to move from line-to-line voltages $$V\_{LL}$$ to line-to-neutral voltages $$V\_{LN}$$.\
For instance, at the inverter output we have:

$$
V\_{A N}=\frac{V\_{A B}-V\_{C A}}{3} \\\[8pt]
V\_{B N}=\frac{V\_{B C}-V\_{A B}}{3} \\\[8pt]
V\_{C N}=\frac{V\_{C A}-V\_{B C}}{3}
$$

Then the instantaneous power is obtained as

$$
P=V\_{A N} i\_A+V\_{B N} i\_B+V\_{C N} i\_C
$$


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/three-phase-two-level-inverter/circuit-description.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.