> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/three-phase-two-level-inverter/exercises/inverter-mode.md).

# Inverter Mode

## Change DC voltage source <a href="#id-9.2.1-changing-dc-voltage-source" id="id-9.2.1-changing-dc-voltage-source"></a>

This exercise is intended to change the value of the DC Voltage source and observe its impact on the levels and waveforms, essentially, the inverter voltages.

For that, keep all the parameters unchanged except for the slider: **Vdc (V)**.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FCox2pDCSmfMr3vSSpF7d%2Fimage.png?alt=media&amp;token=8378566e-8d3c-4894-ab80-68324d4024fd" alt=""><figcaption><p><strong>Figure 25</strong>: Changing DC Voltage Source</p></figcaption></figure>

1. Apply the changes, as shown in the first column of table below, observe the waveforms and fill out the rest.

<table data-search="false"><thead><tr><th>Vdc</th><th>Three levels for U</th><th>Three levels for 0</th><th>Three levels for -U</th></tr></thead><tbody><tr><td><strong>160 V</strong></td><td> </td><td> </td><td> </td></tr><tr><td><strong>140 V</strong></td><td> </td><td> </td><td> </td></tr><tr><td><strong>120 V</strong></td><td> </td><td> </td><td> </td></tr><tr><td><strong>100 V</strong></td><td> </td><td> </td><td> </td></tr><tr><td><strong>90 V</strong></td><td> </td><td> </td><td> </td></tr></tbody></table>

2. Verify that the voltage value of Display<sub>4</sub> follows $$\frac{V\_{dc}}{2}\cdot \text{Reference Amplitude} \cdot \sqrt{3/2}$$  for each Vdc value in the table.

## Change AC-source frequency - synchronization On/Off <a href="#id-9.2.2-changing-ac-source-frequency-synchronization-on-off" id="id-9.2.2-changing-ac-source-frequency-synchronization-on-off"></a>

This exercise is intended to highlight the pulsations phenomenon obtained during the loss of synchronization between the AC-source and the inverter output, a phenomenon like the loss of synchronization between a power grid and a synchronous generator.

1. Change the slider **Frequency (Hz)** and observe the pulsations in the inverter currents as shown in figure 26.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FR4pwczSETiTlCGRVNbWU%2Fimage.png?alt=media&amp;token=c723ec2e-2c0d-40e1-a92e-be688586e7eb" alt=""><figcaption><p><strong>Figure 26</strong>: Changing AC-source Frequency</p></figcaption></figure>

2. Click the **SYNCHRONIZE** button that forces the PWM reference frequency to stick to the BEMF frequency and observe the waveforms of figure 27.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FCiSfc3GKMnE4hHTJkq4D%2Fimage.png?alt=media&amp;token=f279a90c-9b66-44a6-9532-b754085a0404" alt=""><figcaption><p><strong>Figure 27</strong>: Synchronize Button Activated</p></figcaption></figure>

## Change AC-source phase-shift <a href="#inlineextension-9.2.3-changing-ac-source-phase-shift" id="inlineextension-9.2.3-changing-ac-source-phase-shift"></a>

This exercise is intended to show the impact of changing the phase-shift of the AC Source with respect to the reference signal. Using the slider **PhaseShift (Deg)** do the following:

1. Choose positive values, thus rendering the load more inductive, and observe the waveforms of the voltages and currents as shown in figure 28.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fplm9W6Efu5FlAOvoOLXI%2Fimage.png?alt=media&amp;token=5e301fdd-5493-4a63-a83d-a4aa8b2f1e4d" alt=""><figcaption><p><strong>Figure 28</strong>: Changing AC-source Phase-Shift; Load More Inductive</p></figcaption></figure>

2. Repeat the exercise with negative values (capacitive load) as seen in figure 29.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FYds3ULmtvTn6wU0i4IWK%2Fimage.png?alt=media&amp;token=94f72f55-ac3c-43c6-9093-6f3c3ece4e09" alt=""><figcaption><p><strong>Figure 29</strong>: Changing AC-source Phase-Shift; Load More Capacitive</p></figcaption></figure>

## Effect of neutral connection <a href="#id-9.2.4-effect-of-neutral-connection" id="id-9.2.4-effect-of-neutral-connection"></a>

This exercise is intended to show the impact of the neutral connection.

1. Set Vdc to 140 V.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FnmIviTa8InKXh4LY3BdQ%2Fimage.png?alt=media&amp;token=21e37a1a-b532-4d83-a66b-38d720364aea" alt=""><figcaption><p><em><strong>Figure 30</strong>: Neutral Connection Activated and Vdc set to 140 V</em></p></figcaption></figure>

2. Fill out the Impact of neutral connection table when the Neutral Button is pressed or not.

<table><thead><tr><th width="300.39996337890625">Neutral Connection Status</th><th>Disconnected</th><th>Connected</th></tr></thead><tbody><tr><td><strong>Power</strong><sub><strong>1</strong></sub><strong> / Display</strong><sub><strong>1</strong></sub><strong> (W)</strong></td><td> </td><td> </td></tr><tr><td><strong>Power</strong><sub><strong>2</strong></sub><strong> / Display</strong><sub><strong>2</strong></sub><strong> (W)</strong></td><td> </td><td> </td></tr><tr><td><strong>Power</strong><sub><strong>3</strong></sub><strong> / Display</strong><sub><strong>3</strong></sub><strong> (W)</strong></td><td> </td><td> </td></tr><tr><td><strong>THD Inverter Current / Display</strong><sub><strong>6</strong></sub><strong> (%)</strong></td><td> </td><td> </td></tr><tr><td><strong>THD Load Current / Display</strong><sub><strong>7</strong></sub><strong> (%)</strong></td><td> </td><td> </td></tr></tbody></table>

3. How does the neutral connection impact the power flow?
4. How does the neutral connection impact the THD of load and inverter currents?


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-ac-converters/three-phase-two-level-inverter/exercises/inverter-mode.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.