> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-dc-converters/boost-converter/panels-overview.md).

# Panels Overview

## Virtual laboratory

The **Boost Converter** model file, located in the folder **OP1130 - Power Electronics Courseware,** is **PE\_Boost.zip**

When starting the demo, the panel in figure 5 appears first with the default settings.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FnfrFSvlK6pXlF5GoZ1Ym%2Fimage.png?alt=media&amp;token=a430391c-8d2d-441b-86d4-9f3d808fa996" alt=""><figcaption><p><strong>Figure 5</strong>: Start-Up Panel of Boost Converter Laboratory</p></figcaption></figure>

The panel is to be operated as follows:

* In the upper right corner, under Pre-Selected the student can select the **type of load**, which is either resistive or inductive.
* Once load type is selected, the student can select the **load value**. For a resistive load, the scenarios are shown in figure 6; while figure 7 presents the inductive load scenarios.

{% columns %}
{% column %}

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FanXI5gw3EfXY3yb45sw3%2Fimage.png?alt=media&amp;token=43bdc181-2aea-48b8-8476-7f4ca6dce582" alt=""><figcaption><p><strong>Figure 6</strong>: Changing the Resistive Load Value</p></figcaption></figure>
{% endcolumn %}

{% column %}

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FenWdUnG5Kq3mzkkoGNmI%2Fimage.png?alt=media&amp;token=09070a52-2788-4572-a9de-77cd6a6310c8" alt=""><figcaption><p><br><strong>Figure 7</strong>: Changing the Inductive Load Value</p></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

* In the lower left corner, the student can change control parameters and can switch control buttons (to enable/disable their associated functions).&#x20;
* After setting the control parameters, the students can observe the waveforms displayed in four scopes.&#x20;

### Control parameters of the boost converter

| Control Parameters           | Default Value | Interval of Variation |
| ---------------------------- | ------------- | --------------------- |
| **DC Source Voltage (V)**    | 100           | \[0; 200]             |
| **Switching Frequency (Hz)** | 1500          | \[1500; 3600]         |
| **Duty Cycle**               | 0.5           | \[0.1; 0.9]           |
| **Inductance (mH)**          | 100           | 50 or 100             |
| **Capacitance (µF)**         | 400           | 400 or 800            |

### Control buttons and LED fuse status indicators

<table data-search="false"><thead><tr><th width="140">Control Buttons</th><th width="99.5999755859375"></th><th>Associated Functions</th></tr></thead><tbody><tr><td><strong>Trigger</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FGNPhcs0sHBS7Zh0caL2s%2Fimage.png?alt=media&amp;token=d80c4343-3028-4494-aaa5-ba82e1c3e036" alt=""></td><td>The waveforms are not triggered. They “move”.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FzcDScx6EazmzWi4w1IuW%2Fimage.png?alt=media&amp;token=08d267ce-f665-4bb5-890e-c1933ab7ce9f" alt=""></td><td>The waveforms are triggered with respect to a reference signal.</td></tr><tr><td><strong>Reset</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FGNPhcs0sHBS7Zh0caL2s%2Fimage.png?alt=media&amp;token=d80c4343-3028-4494-aaa5-ba82e1c3e036" alt=""></td><td>The reset push button is disabled.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FzcDScx6EazmzWi4w1IuW%2Fimage.png?alt=media&amp;token=08d267ce-f665-4bb5-890e-c1933ab7ce9f" alt=""></td><td>The reset push button is activated and simulates replacement of fuses after a fault.</td></tr><tr><td><strong>HELP / BACK</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FMdwKyVPMEEsxUFycsDRI%2Fimage.png?alt=media&amp;token=e9f43ea1-0735-4598-81a6-034f8757d907" alt=""></td><td>Open the Help page, where a summary of the boost converter and its nameplate ratings (see Table 4) are shown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FJwJUuGkMex2i9kiZGi1p%2Fimage.png?alt=media&amp;token=4334f160-0b45-4039-bb46-cc19a318c78d" alt=""></td><td>Close the Help page and go back to the simulations.</td></tr><tr><td><strong>Fuse</strong></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FXMiLDY930zdIxkjo95dF%2Fimage.png?alt=media&amp;token=9aa49fe8-ce8d-4e15-a037-24bb1e2c66c2" alt=""></td><td><strong>Red</strong>: The protection fuse is blown.</td></tr><tr><td></td><td><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FufLjD7C7DrroYd7lWCeW%2Fimage.png?alt=media&amp;token=110185b6-9735-44f2-960a-f9fe284c02b7" alt=""></td><td><strong>Green</strong>: The protection fuse is intact.</td></tr></tbody></table>

### Scopes and displayed waveforms

On scope localization, the indices used will be like those of matrix elements.\
Hence, the scope located in the upper left corner (first row, first column) is denoted Scope<sub>11</sub>, while the scope in the upper right corner (first row, second column) is Scope<sub>12</sub>.\
By the same token, the scope in the lower left corner is Scope<sub>21</sub> while the scope in the lower right corner is Scope<sub>22</sub>.

<table><thead><tr><th width="140">Scope</th><th>Content of Scopes &#x26; Displayed Waveforms</th></tr></thead><tbody><tr><td><strong>Scope</strong><sub><strong>11</strong></sub></td><td>Load output voltage and switching signal (multiplied by a factor of 30)</td></tr><tr><td><strong>Scope</strong><sub><strong>21</strong></sub></td><td>Input current of the DC source</td></tr><tr><td><strong>Scope</strong><sub><strong>12</strong></sub></td><td>Load output current</td></tr><tr><td><strong>Scope</strong><sub><strong>22</strong></sub></td><td>Input power of the DC source and load output power</td></tr></tbody></table>

{% hint style="info" %}
The knobs “y-axis offset” and “y-scale/div” can be used to modify the range settings in the y-axis for the scopes.
{% endhint %}

### Boost converter nameplate ratings

| **Nominal Power**  | 10 kW       |
| ------------------ | ----------- |
| **Input Voltage**  | \[0; 200] V |
| **Output Voltage** | \[0; 500] V |
| **Output Current** | \[0; 50] A  |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-dc-converters/boost-converter/panels-overview.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.