> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-dc-converters/buck-converter/exercices/buck-converter-with-inductive-load.md).

# Buck Converter With Inductive Load

## Introduction

In the panel, choose from the menu **Pre-Selected**: Inductive Load and select the R=1.25 ohms and L=20mH for **exercises 7 to 10**.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fx69iz4lNBnprUiCTfUVn%2Fimage.png?alt=media&amp;token=2884a570-a392-4d0e-b6df-b62529ab0e0e" alt=""><figcaption><p>Figure 15: Buck Panel with an Inductive Load with R=12.5 ohms and L =20 mH</p></figcaption></figure>

### Default Parameters <a href="#default-parameters" id="default-parameters"></a>

* Source Voltage: V<sub>DC</sub>= 100 V
* L= 100 mH
* C= 400 µF
* Resistive load (R= 25 Ω)
* Switching Frequency: 1500 Hz
* Duty Cycle: 0.5

## 7 - Varying duty ratio <a href="#exercise-1-varying-duty-ratio" id="exercise-1-varying-duty-ratio"></a>

1. Set V<sub>DC</sub> to 300 V and switching frequency to 1500 Hz and vary the duty ratio from 10% to 90% and run the model.
2. See the effect of change in output voltage and measure the average DC load voltage for the corresponding duty ratio values, and complete the following table with the theoretical average output voltage.

<table><thead><tr><th>Duty Cycle (%)</th><th width="60">10</th><th width="60.00006103515625">20</th><th width="59.99993896484375">30</th><th width="59.99993896484375">40</th><th width="60">50</th><th width="60">60</th><th width="59.99993896484375">70</th><th width="60">80</th><th width="60.0001220703125">90</th></tr></thead><tbody><tr><td><strong>Measured average load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Calculated average load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr></tbody></table>

3. What effect will a duty ratio at the buck converter have on the voltage output? Explain.
4. Compare the observed average output voltage results with the calculated ones.

## 8 - Varying switching frequency <a href="#exercise-2-varying-switching-frequency" id="exercise-2-varying-switching-frequency"></a>

1. Set V<sub>DC</sub> to 360 V, duty cycle to 0.5 and vary the switching frequency from 1500 Hz to 3600 Hz.\
   Observe simulation results and complete the following table.

<table><thead><tr><th>Switching Frequency (Hz)</th><th width="80">1800</th><th width="80">1620</th><th width="80">1800</th><th width="80">2400</th><th width="80">3000</th><th width="80">3600</th></tr></thead><tbody><tr><td><strong>Measured maximum value of inductor current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Calculated maximum value of inductor current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Measured average load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Measured average load current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr></tbody></table>

2. What is the effect of change in the frequency on the inductor current?

## 9 - Varying DC source voltage <a href="#exercise-3-varying-dc-source-voltage" id="exercise-3-varying-dc-source-voltage"></a>

1. Set the duty ratio to 50% and the switching frequency to 1500 Hz, and complete the following table for different values of the input voltage:

<table><thead><tr><th>DC source voltage (V)</th><th width="80">100</th><th width="79.20001220703125">150</th><th width="79.20001220703125">200</th><th width="79.99993896484375">300</th><th width="80">350</th><th width="80">400</th></tr></thead><tbody><tr><td><strong>Measured average load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Calculated average load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Measured average load current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Calculated average load current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td><td> </td></tr></tbody></table>

2. What is the effect of varying DC source voltage on the inductor’s current waveform?\
   Explain it theoretically.
3. Set V<sub>DC</sub> voltage to 350 V, switching frequency to 1500 Hz and duty cycle to 0.5, calculate the theoretical values of input and output powers and compare them with the observed ones.\
   What do you conclude?

## 10 - Changing value of L <a href="#exercise-4-changing-value-of-l" id="exercise-4-changing-value-of-l"></a>

1. From the panel, change the inductance L\_buck from 100 mH to 50 mH.\
   Set V<sub>DC</sub> to 300 V, duty cycle to 0.5, and C =400 µF.
2. Vary the switching frequency from 1500 Hz to 3600 Hz.\
   Observe simulation results and complete the following table:

<table><thead><tr><th>Switching Frequency (Hz)</th><th width="79.79998779296875">1500</th><th width="80">1800</th><th width="80">2400</th><th width="80">3000</th><th width="80">3600</th></tr></thead><tbody><tr><td><strong>Measured average load voltage (V)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td></tr><tr><td><strong>Measured average load current (A)</strong></td><td> </td><td> </td><td> </td><td> </td><td> </td></tr></tbody></table>

3. What is the effect of decreasing the value of the inductance L\_buck?\
   *Hint: Compare to results obtained in exercise 2.*

## &#x20;11 - Changing value of R <a href="#exercise-6-changing-value-of-r" id="exercise-6-changing-value-of-r"></a>

1. From panel, change the inductive load value from R= 8.5 Ω and L=20mH, which is equivalent to changing the resistance value of the load.
2. Set V<sub>DC</sub> to 300 V, switching frequency to 1500 Hz, duty cycle to 0.5, L=100 mH and the capacitance as C=400 µF.
3. What is the effect of decreasing the resistive load value on the load current, inductor current, load voltage, and output power?\
   Explain your observations.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/dc-to-dc-converters/buck-converter/exercices/buck-converter-with-inductive-load.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.