> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/three-phase-three-level-neutral-point-clamped-converter/circuit-description.md).

# Circuit Description

## Converter topology <a href="#id-2.1.-converter-topology" id="id-2.1.-converter-topology"></a>

The Three-Phase Three-Level NPC converter is shown in Figure 3 below.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FQiWTWIYlVZqdhPQqZZXv%2F6a17b09f-98dd-4bcd-be72-0352892131cf.png?alt=media&amp;token=7375c810-5c62-4f53-9d94-706ffabb23fc" alt=""><figcaption><p><strong>Figure 3:</strong> Three-Phase Three-Level NPC Converter</p></figcaption></figure>

The bridge is composed of three arms.\
Each arm comprises (i) four IGBT associated to their antiparallel diodes and (ii) two additional diodes with their midpoint $$O$$ clamped to the ground together with the midpoint of the capacitors.\
The IGBT/diode switches are numbered $$S\_1$$ to $$S\_{12}$$ and the remaining six diodes go from $$S\_{13}$$ to $$S\_{18}$$.

The converter has three inputs: (i) positive and (ii) negative terminals of the DC voltage source and (iii) the ground connected to the capacitors’ midpoint $$O$$.\
It also has three outputs  $$A$$,  $$B$$ and $$C$$,which feed the three-phase load.

The role of the two identical capacitors $$C\_1$$ and $$C\_2$$ is to create the midpoint together with the two voltage levels $$\frac{U}{2}$$ and $$-\frac{U}{2}$$ .\
In the sequel, an exercise will be dedicated to the dimensioning of these two identical capacitors.

It is noteworthy that the neutral of the load might be unreachable, which corresponds to practical cases, for example a delta-connected load.\
Consequently, the ground $$O$$ of the NPC will not be connected to the neutral $$N$$ of the load at any time. Therefore, the voltage $$V\_{on}$$ will not be identically zero.

Hence, for a symmetric load, we have:

$$
V\_{AN} + V\_{BN} + V\_{CN} = 0 \\\[8pt]
$$

which leads to:

$$
V\_{ON} = -\frac{V\_{AO} + V\_{BO} + V\_{CO}}{3} \\\[8pt]
$$

Besides the practical aspect, removing the connection between the electrical points $$N$$ and $$O$$ has its benefit harmonic-wise for symmetrical load.\
Indeed, the absence of connection eliminates all the odd harmonics that are multiple of three, which is explained thoroughly in [References](https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/three-phase-three-level-neutral-point-clamped-converter/references.md).\
The interested reader is redirected there for more details.

### Control of the switches & PWM generation <a href="#inlineextension-2.2.-control-of-the-switches-and-pwm-generation" id="inlineextension-2.2.-control-of-the-switches-and-pwm-generation"></a>

The control of the switches of the first arm, that is displayed in Figure 4 below, is explained below. The same control is to be applied for arms two and three with a phase shift of -120<sup>o</sup> and +120<sup>o</sup>, respectively.

The PWM train is generated using the method of intersection between the reference signal that is a sine-wave signal oscillating at either 60 Hz or 50 Hz, and two triangular carriers, one positive and one negative, oscillating at the switching frequency.\
The positive and negative carriers operate on the positive and negative parts of the reference, respectively, as illustrated in Figure 5 below.

The switching frequency is a user-controlled parameter, varying between 900 Hz and 3000 Hz.\
It is up to the user to select switching frequency values that are multiples of 60 (or 50) if 60 Hz (or 50 Hz) is chosen as a reference frequency.

The reason behind having two carriers (instead of one) is the fact that each arm contains four IGBTs (instead of two IGBTs, as is the case in a two-level inverter).\
This technique is classified under the category of *multi-carriers PWM generation* for multi-levels inverters.\
Exhaustive literature can be found covering this topic.

From the waveforms shown below one can notice that during the positive part of the reference:

* &#x20;$$S\_2$$ is always ON and $$S\_4$$ is always OFF.
* &#x20;$$S\_1$$ and $$S\_3$$ are complementary offering, thus the two levels $$\frac{U}{2}$$ or 0

Following the same reasoning, during the negative part of the reference:

* &#x20;$$S\_3$$ is always ON and $$S\_1$$ is always OFF.
* &#x20;$$S\_2$$ and $$S\_4$$ are complementary offering, thus the two levels $$-\frac{U}{2}$$ or 0

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FLG53mOfbv7ABjiwkfo21%2Fe2aa9258-8074-40bb-b0fd-1a24ae7fb24b.png?alt=media&amp;token=66e829e7-a98e-4d39-bb04-b42fa33be546" alt="" width="320"><figcaption><p><strong>Figure 4:</strong> First Arm of the NPC Converter</p></figcaption></figure>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FBlOeYZIfPRhGmN3ZHv9i%2Fb0a7b534-6dcb-4e5f-a23c-9226825aef67.png?alt=media&amp;token=db122a1c-06cb-4729-a773-254dd912ff69" alt=""><figcaption><p><strong>Figure 5:</strong> PWM Generation for the First Arm of the NPC Converter</p></figcaption></figure>

## Output voltages and waveforms <a href="#inlineextension-2.3.-output-voltages-and-waveforms" id="inlineextension-2.3.-output-voltages-and-waveforms"></a>

The voltages at the output of the inverter can take a specific number of values (levels), depending on the switch combinations.\
Table 1 below summarizes these values, while Figure 6 below shows the voltages waveforms.\
It is noteworthy that, in this section, we will consider all the possible voltage levels regardless of the control of the switches generating them, as [**exercise 4.1.3**](https://www.opal-rt.com/pages/sICsNf1RcAb6bUavvwY0#inlineextension-4.1.3.-voltage-levels-and-associated-switches-control) in the sequel will be dedicated to that matter.

For instance, when the DC voltage source is:

&#x20;$$U = 120,\text{V}$$

the corresponding levels for $$V\_{AO}$$ are:

&#x20;$$0 ;\text{and}; \pm \frac{U}{2} = \pm 60,\text{V}$$

while for the line-to-neutral voltage $$V\_{AN}$$ they become: $$0,; \pm \frac{U}{6} = \pm 20,\text{V},; \pm \frac{U}{3} = \pm 40,\text{V},; \pm \frac{U}{2} = \pm 60,\text{V},; \pm \frac{2U}{3} = \pm 80,\text{V}$$

And finally, for the line-to-line voltage $$V\_{AB}$$ we have:

&#x20;$$0,; \pm \frac{U}{2} = \pm 60,\text{V},; \pm U = \pm 120,\text{V}$$

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2Fc1zvUhe36h5PRBJX5BFt%2Fd9e7f919-478e-471f-badd-38e46953c2c0.png?alt=media&amp;token=f6b57e1b-f42b-452a-aa34-f2e059d416fd" alt=""><figcaption><p>Voltage levels at the inveter output</p></figcaption></figure>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FvBxsiZve0Ec4znv4J8P4%2F0c53c2b1-8034-4ddf-bcee-46e11892b442.png?alt=media&amp;token=93affb5a-0009-42b4-b586-01f3dd84bde3" alt=""><figcaption><p><strong>Figure 6:</strong> Voltages V<sub>AO</sub>, V<sub>AN</sub>, and V<sub>AB</sub></p></figcaption></figure>

## Load and filter in inverter mode <a href="#id-2.4.-load-and-filter-in-inverter-mode" id="id-2.4.-load-and-filter-in-inverter-mode"></a>

In inverter mode, the load and filter are given in figure 7 below:

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FoXgjF9Xpk778mq7EKIB9%2F722f93f8-bebc-40ae-ad13-39b7bab6c52a.png?alt=media&amp;token=a07a4143-5e7f-4104-be1e-ddc178478565" alt=""><figcaption><p><strong>Figure 7:</strong> Load and Filter in Inverter Mode</p></figcaption></figure>

### Load <a href="#id-2.4.1.-load" id="id-2.4.1.-load"></a>

The load is composed of the combination in series of (i) a constant resistance $$R\_L$$ , (ii) a constant inductance $$L\_L$$ and (iii) a controllable three-phase AC-source.\
Therefore, the student controls the three parameters of the AC-source, namely, the amplitude, frequency, and phase shift.\
In Exercises showing the impact of changing these parameters will be covered thoroughly.

### Filter <a href="#id-2.4.2.-filter" id="id-2.4.2.-filter"></a>

The filter is composed of inductances  $$L\_L$$ in series with the load, while the capacitances $$C\_F$$ are mounted in delta configuration between phases.\
The filter inductance value corresponds to 10% of the load inductance.\
The value of the capacitance will be computed in an exercise, later, to ensure a cut-off frequency of 600 Hz, which represents 10x the reference frequency (60 Hz).

Note that the capacitors can be connected or disconnected as shown in Figure 7 above; exercises covering this matter will be given too.

## Load and filter in rectifier mode <a href="#id-2.5.-load-and-filter-in-rectifier-mode" id="id-2.5.-load-and-filter-in-rectifier-mode"></a>

When simulating the converter in rectifier mode, the AC-source on the load side becomes the generator.\
Additionally, the DC voltage source is disconnected and the PWM generator is disabled, rendering the rectifier passive (i.e., the DC voltage at the output of the rectifier cannot be regulated).\
There is a possibility to connect/disconnect a resistive load at the output of the rectifier. Figure 8 below shows the circuit in rectifier mode.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2F3wp10jBC93rpLIoXRPXi%2Fc0c1b556-d42c-41e7-8160-ca0b6613a4c6.png?alt=media&amp;token=4a6f528a-6fb5-4580-998f-96afdfded55f" alt=""><figcaption><p><strong>Figure 8:</strong> Load and Filter in Rectifier Mode</p></figcaption></figure>

## Converter parameters and nameplate <a href="#id-2.6.-converter-parameters-and-nameplate" id="id-2.6.-converter-parameters-and-nameplate"></a>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FKReNReGg3TLZ6Kyv1hfw%2F9ef3627e-a6ef-4bb6-83a6-f295576da5fb.png?alt=media&amp;token=a55da6f8-a87d-4cb5-9982-3918d44952c5" alt=""><figcaption><p>Converter parameters and nameplate ratings</p></figcaption></figure>

## Measurements <a href="#inlineextension-2.7.-measurements" id="inlineextension-2.7.-measurements"></a>

&#x20;Three spots were considered for current, voltage and power measurements, as shown in Figure 9 below:

* The DC bus at the input of the converter bridge.
* The AC bus at the output of the converter bridge.
* The input of the load.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FI8q9cfNtOmEs4YK9jMJY%2F672619af-3244-4527-b3c8-78ece82028d2.png?alt=media&amp;token=78d7ab77-29ff-43cf-8eab-7a2dd0cf357c" alt=""><figcaption><p><strong>Figure 9:</strong> Measurements</p></figcaption></figure>

It is worth noticing that for the three-phase power measurements, i.e., at the second and third spots, a transformation is required first to move from line-to-line voltages  $$V\_{LL}$$ to line-to-neutral voltages $$V\_{LN}$$ .\
For instance, at the inverter output we have:

$$
V\_{AN} = \frac{V\_{AB} - V\_{CA}}{3} \\\[8pt]
V\_{BN} = \frac{V\_{BC} - V\_{AB}}{3} \\\[8pt]
V\_{CN} = \frac{V\_{CA} - V\_{BC}}{3} \\\[8pt]
$$

Then the instantaneous power is obtained as

$$
P = V\_{AN} i\_A + V\_{BN} i\_B + V\_{CN} i\_C \\\[8pt]
$$


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/power-electronics/three-phase-three-level-neutral-point-clamped-converter/circuit-description.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.