> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/courseware/electric-courseware/renewable-energy/photovoltaic-generation-system-pvgs/exercises.md).

# Exercises

The objective of this experiment is to study the steady-state operation of the PVGS. Real-time simulation results are shown in the “Main Interface” and “Help Contents” tabs of the laboratory panel.

## MPPT operation mode <a href="#mppt-operation-mode" id="mppt-operation-mode"></a>

1. What active power is achieved under standard test conditions (STC) with *E* = 1000 W/m<sup>2</sup> and temperature *ϑ* = 25 °C?
2. What active power is achieved under normal operating test conditions (NOTC) with E = 800 W/m2, an environmental temperature of 20 °C and a wind velocity of 1 m/s.\
   The cell temperature is approximately ϑ = 45 °C.
3. Calculate the efficiency, shown in the equation below, for the cases of STC and NOTC.

$$
\eta = \frac{P\_{MPP}}{E \cdot A} \\\[8pt]
$$

4. Compare and explain the results, while assuming an area of *A = 30 m*<sup>*2*</sup>.\
   It should be noted that the value of active power *P*<sub>*MPP*</sub> can be obtained directly from the “Help Contents” tab.\
   Alternatively, the student could choose to measure the active power (p.u.) in Scope<sub>31</sub>, and then multiply by the obtained value by the base power chosen as 750 kVA.
5. Assuming a summer day in August in Hamburg (HH) and in Munich (M), both with 28 °C, how much does the active power *P*<sub>*MPP*</sub> differ?\
   Compare it with the values that can be achieved in winter (January; 5 °C). Use:
   * E<sub>sum,HH,Aug</sub> = 128 kWh/m<sup>2</sup>
   * E<sub>sum,M,Aug</sub> = 150 kWh/m<sup>2</sup>
   * E<sub>sum,HH,Jan</sub> = 20 kWh/m<sup>2</sup>
   * E<sub>sum,M,Jan</sub> = 33 kWh/m<sup>2</sup>

{% hint style="info" %}
Note that the given global radiation the monthly sum (31 days) and not the current value that is needed for the simulation.\
For converting, you can assume that the irradiation is constant over the whole month.\ <i class="fa-lightbulb-on">:lightbulb-on:</i> *(E = E*<sub>*sum*</sub>*/(number of hours in a month))*
{% endhint %}

6. Examine the temperature dependency (figure 9 below shows the I-U-characteristic depending on the temperature of a PV cell, figure 10 below shows the P-U-characteristic), first under the assumption that the ambient temperature is equal to one of the solar cells and is 20 °C.\
   Investigate the effect of the temperature, considering that the solar module’s temperature *ϑ* is higher than the ambient temperature *T*<sub>*a*</sub>:

$$
\vartheta = T\_a + c \cdot \frac{E}{1000,\text{W/m}^2} \\\[8pt]
$$

7. Compare solar modules with free elevation (c = 22 °C) with those on roof surfaces with poor rear ventilation (c = 32 °C).\
   (Roof-integrated systems without rear ventilation have a significantly higher constant c = 43 °C and those that are facade-integrated generally have higher constant than roof-integrated ones.)\
   Assume an irradiance of E = 600 W/m<sup>2</sup>.
8. Explain the importance of reactive power that can be provided by the PVGS.
9. Set the reactive power reference value to *Q*<sub>*ref*</sub> = 1 p.u. and irradiance to *E* = 600 W/m<sup>2</sup>.\
   Explain what happens.

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FZqh0pSC5AdzHZ4xiVyG4%2F1034b1b2-dd3d-4f49-bdb3-c61112b13281.png?alt=media&amp;token=19bcbe1b-037b-46af-913a-d7d89da4623a" alt=""><figcaption><p><strong>Figure 9</strong>: Temperature Dependency of I-U-characteristics of a PV Cell  <a href="https://www.opal-rt.com/docs/courseware/electric-courseware/renewable-energy/photovoltaic-generation-system-pvgs/references.md"><strong>[3]</strong></a></p></figcaption></figure>

<figure><img src="https://4054096626-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FYbyVjpgEQX9nfCkpYoFP%2Fuploads%2FRdyqoV6tRUd27Pgc2mZ5%2Fe63e8220-839a-4378-9c82-e5e97f569d98.png?alt=media&amp;token=3bc8b2ea-f25c-4563-8f71-6e2250dd12cb" alt=""><figcaption><p><strong>Figure 10</strong>: Temperature Dependency of P-U-characteristics of a PV Cell <a href="https://www.opal-rt.com/docs/courseware/electric-courseware/renewable-energy/photovoltaic-generation-system-pvgs/references.md"><strong>[3]</strong></a></p></figcaption></figure>

## Curtailment operation mode <a href="#curtailment-operation-mode" id="curtailment-operation-mode"></a>

1. Explain the importance of the curtailment mode.
2. Start with *ϑ* = 25 °C, *E* = 600 W/m<sup>2</sup> and *P*<sub>*ref*</sub> = 0.5 p.u.\
   Determine the minimum irradiance that is required so that the active power can follow *P*<sub>*ref*</sub>.

## Comprehension task <a href="#comprehension-task" id="comprehension-task"></a>

Think about the simulations performed, how does the PVGS challenge the grid?\
Are there other problems that were not considered in the simulations?


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/courseware/electric-courseware/renewable-energy/photovoltaic-generation-system-pvgs/exercises.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.