> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/ehs/3.7/model-in-schematic-editor/library-blocks-reference/machines-blocks/permanent-magnet-synchronous-machine-3-phase-open-end-winding.md).

# Permanent Magnet Synchronous Machine 3-phase Open end Winding

## Description

<figure><img src="https://521571437-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fo99Izmvvw5eHT4ldzI4g%2Fuploads%2Fgit-blob-c2db4c2a8c363b920e787b30401d8f5d67c99e98%2FSE_PMSM_OEW_block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **Permanent Magnet Synchronous Machine 3-phase Open-end Winding** block implements a three-phase PMSM open-end winding (PMSM OEW) model with optional resolver and encoder sensors.

It computes machine electrical behavior in the phase domain using phase-domain states and the Backward Euler integration method. An amplitude-invariant Park (DQ0) transform is used for analysis and control, and the torque expression includes the effect of zero-sequence current.

{% hint style="info" %}
This block is only available in the eHS library.
{% endhint %}

### **Equations & characteristics** <a href="#equations-and-characteristics" id="equations-and-characteristics"></a>

#### General PMSM solver equations <a href="#general-pmsm-solver-equation" id="general-pmsm-solver-equation"></a>

The equation of the PMSM model can be expressed as follows:

$$
\begin{aligned} I\_{abc} = \[L\_{abc}(\theta)]^{-1} \cdot \left\[\int \left(V\_{abc} - R,I\_{abc}\right),dt - \psi\_{abc}\right] \end{aligned}
$$

where **L**<sub>**abc**</sub> is the time-varying inductance matrix (global inductance for DQ0 and VDQ models), **I**<sub>**abc**</sub> is the stator current inside the winding, **R** is the stator resistance, **V**<sub>**abc**</sub> is the voltage across the stator windings and **ψ**<sub>**abc**</sub> defines the magnet flux linked into the stator windings.

{% hint style="info" %}
The solver computes the outputs in phase domain, using phase domain states. The integration type used is Backward Euler.
{% endhint %}

#### Standard DQ0 motor characteristics <a href="#standard-dq0-motor-characteristics" id="standard-dq0-motor-characteristics"></a>

Under normal conditions, the ideal sinusoidal stator voltages of the PMSM, back-EMFs, and inductances all have sinusoidal shapes. One can transform the equation using the Park transformation with a referential locked on the rotor position **θ** using the following two equations:

$$
\begin{bmatrix}
V\_{ds} \\
V\_{qs} \\
V\_{0s}
\end{bmatrix}
=============

\mathbf{T}
\begin{bmatrix}
V\_{as} \\
V\_{bs} \\
V\_{cs}
\end{bmatrix} \\\[8pt]

T = \frac{2}{3}
\begin{bmatrix}
\cos(\theta\_e) &
\cos(\theta\_e - \frac{2\pi}{3}) &
\cos(\theta\_e + \frac{2\pi}{3}) \\\[8pt]
-\sin(\theta\_e) &
-\sin(\theta\_e - \frac{2\pi}{3}) &
-\sin(\theta\_e + \frac{2\pi}{3}) \\\[8pt]
\frac{1}{2} &
\frac{1}{2} &
\frac{1}{2}
\end{bmatrix}
$$

and

$$
\begin{bmatrix}
V\_{as} \\\[8pt]
V\_{bs} \\\[8pt]
V\_{cs}
\end{bmatrix}
=============

T^{-1}
\begin{bmatrix}
V\_{ds} \\\[8pt]
V\_{qs} \\\[8pt]
V\_{0s}
\end{bmatrix}
\\\[8pt]

T^{-1} =
\begin{bmatrix}
\cos(\theta\_e) & -\sin(\theta\_e) & 1 \\\[8pt]
\cos(\theta\_e - \tfrac{2\pi}{3}) & -\sin(\theta\_e - \tfrac{2\pi}{3}) & 1 \\\[8pt]
\cos(\theta\_e + \tfrac{2\pi}{3}) & -\sin(\theta\_e + \tfrac{2\pi}{3}) & 1
\end{bmatrix}
\\\[8pt]
$$

The Park transform (also called ‘DQ’ transform) reduces sinusoidal varying quantities of inductances, flux, current, and voltage to constant values in the D-Q frame thus greatly facilitating the analysis and control of the device under study.

It is important to note that there are many different types of Park transforms and this often leads to confusion when interpreting the motor states inside the D-Q frame. The one used here presents the advantage of being amplitude-invariant which means that the peak amplitude of the signals in the D-Q frame by performing a transformation will be numerically equal to the one computed in the phase domain.

The corresponding equations in the DQ0 domain, for representation, are:

$$
\begin{bmatrix}
\phi\_d \\\[8pt]
\phi\_q \\\[8pt]
\phi\_0
\end{bmatrix}
=============

\begin{bmatrix}
L\_d & 0 & 0 \\\[8pt]
0 & L\_q & 0 \\\[8pt]
0 & 0 & L\_0
\end{bmatrix}
\begin{bmatrix}
i\_d \\\[8pt]
i\_q \\\[8pt]
i\_0
\end{bmatrix}
\+
\begin{bmatrix}
\phi\_{PM} \\\[8pt]
0 \\\[8pt]
0
\end{bmatrix}
\\\[16pt]

V\_d = R\_s i\_d + L\_d \frac{di\_d}{dt} - \omega\_e L\_q i\_q \\\[8pt]

V\_q = R\_s i\_q + L\_q \frac{di\_q}{dt} + \omega\_e (L\_d i\_d + \phi\_{PM}) \\\[8pt]

V\_0 = R\_s i\_0 + L\_0 \frac{di\_0}{dt} + e\_0 \\\[8pt]
$$

With this transform (and only this transform) the PMSM torque can be expressed by the following equation, where ***pp*** is the **number of pole pairs**.

$$
T\_e = pp \cdot \Bigl\[ \left( e\_a \cdot i\_a + e\_b \cdot i\_b + e\_c \cdot i\_c \right)+ \frac{3}{2} \cdot (L\_d - L\_q) \cdot i\_d \cdot i\_q \Bigr]
\\\[8pt]
$$

where

$$
\[, e\_a = u\_a \cdot \psi\_m ,]
\\\[8pt]
$$

same for Phase ***b*** and ***c***.

and **u**<sub>**a**</sub> is the unit vector template of the BackEMF profile and $$\psi\_m ,$$is the flux linkage constant.

{% hint style="info" %}
The synchronous component of Torque includes impact due to Zero Sequence Current.
{% endhint %}

Figure 1 explains the principle of the Park transform. Considering fixed ABC referential with all quantities (***V***<sub>***bemf***</sub>, *motor current **I***) rotating at the electric frequency **ω**, if we observe these quantities in a D-Q frame turning at the same speed we can see that the motor quantities will be constant.

This is easy to see for the Back-EMF voltage ***V***<sub>***bemf***</sub> that directly follows the Q-axis (because the magnet flux is on the D-axis by definition). In Figure 1, ***I*** leads the Q-axis by an angle called **β** (beta). The modulus of the vector ***I*** is called ***I***<sub>***amp***</sub>. In the figure below, **θ** is the rotor angle, aligned with the D-axis.

<figure><img src="https://521571437-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fo99Izmvvw5eHT4ldzI4g%2Fuploads%2Fgit-blob-63e181a04eb67e8d2521aa319c4c69730a96e471%2FSE_Park-transform.png?alt=media" alt=""><figcaption><p>Figure1: Park Transform with definition of Theta and Beta</p></figcaption></figure>

### Mechanical model

The equation of the mechanical model in torque mode can be expressed as follows

$$
\omega\_r\left\[k+1\right]=a \times \omega\_r\left\[k\right]+b \times \left(T\_{e}\left\[k\right]-T\_{l}\left\[k\right]-T\_{f,s}\left\[k\right]\right)
$$

with

$$
a=1-\frac{F\_vT\_S}{J} \\\[8pt]
b=\frac{30}{\pi}\frac{T\_S}{J} \\\[8pt]
$$

where $$\omega\_r$$ is the rotor speed in RPM, $$T\_e$$ is the electromagnetic torque in $$N.m$$, $$T\_i$$ is the torque command in $$N.m$$, $$F\_v$$ is the viscous friction coefficient in $$N.m.s/rad$$, $$J$$ is the rotor moment of inertia in $$kg.m^2$$, and $$T\_s$$ the time step in $$s$$. There is a dead-zone implementation with the static friction torque $$T\_{f,s}$$, if the net torque doesn't exceed the static friction torque threshold value $$F\_s$$, given in $$N.m$$, the speed remains zero.

In speed mode, the rotor speed is directly set to the speed command $$\omega\_{r,c}$$.

A resolver is a rotary transformer where the magnitude of the signal through the resolver windings varies sinusoidally as the shaft rotates.

## Single excitation resolver <a href="#single-excitation-resover" id="single-excitation-resover"></a>

The equations of the resolver can be expressed as follows:

$$
\theta\_{res}=\left(\theta\_{mec}+\theta\_{offset}\right) R\_{pp} \\\[8pt]
\text{cosine}=\text{Excitation} \times \left\[ R\_{cc} \cos \left( \theta\_{res} \right) + R\_{cs} \sin \left( \theta\_{res} \right) \right] \\\[8pt]
\text{sine}= \left(-1\right)^{R\_{dir}} \times \text{Excitation} \times \left\[ R\_{sc} \cos \left( \theta\_{res} \right) + R\_{ss} \sin \left( \theta\_{res} \right) \right]
$$

where $$\theta\_{res}$$ is the resolver angle, $$\theta\_{mec}$$ is the mechanical angle of the machine, $$\theta\_{offset}$$ is the angle offset, $$R\_{pp}$$ is the number of pole pairs of the resolver, $$R\_{cc}$$, $$R\_{sc}$$, $$R\_{cs}$$, and $$R\_{ss}$$ are the resolver sine cosine gains and $$R\_{dir}$$ is the direction of the sensor rotation (0 = clockwise, 1 = counterclockwise).

{% hint style="info" %}
$$R\_{dir}$$ does not have an effect to the resolver angle, but change the resolver sine sign to match the counterclockwise convention.
{% endhint %}

When the gains are set to its default values ( $$R\_{cc}=1$$, $$R\_{sc}=0$$, $$R\_{cs}=0$$, and $$R\_{ss}=1$$), the sensor rotation is clockwise, and the excitation is a sinusoidal wave ( $$\text{Excitation}=\sin 2 \pi f t$$, where $$f$$ is the excitation frequency), the outputs are given by the following expressions:

$$
\text{cosine}=\sin \left( 2 \pi f t \right) \times \cos \left( \theta\_{res} \right) \\\[8pt]
\text{sine}= \sin \left( 2 \pi f t \right) \times \sin \left( \theta\_{res} \right)
$$

It means the excitation signals are modulated by the sine and cosine of the rotor position angle.

## **Excitation source**

The excitation signal can be selected among one of the following options:

* DC: a continuous signal is used as excitation, so the outputs are $$\text{cosine}= \cos \left( \theta\_{res} \right)$$ and $$\text{sine}= \sin \left( \theta\_{res} \right)$$;
* AC: a constant-frequency sinusoidal, unitary amplitude waveform is used as excitation

  $$\text{Excitation}=\sin 2 \pi f t$$, so the outputs are those expressed in the previous section.
* External: a external signal, coming from one of the analog inputs, is used as excitation. This incoming signal may be rescaled by the Analog Input Differential Rescaling module (AIR).

## **Resolver gains**

The resolver gains can be used to simulate non-ideal conditions of the sensor, occurring due to manufacturing imperfections.

**Amplitude imbalance:** Output phases have unequal inductances. Assuming the coupling between the rotor excitation winding and the cosine winding as the reference:

$$
\begin{aligned}
\left\[\begin{matrix}R\_{cc} & R\_{cs}\R\_{sc} & R\_{ss}\end{matrix}\right]
\end{aligned}=\begin{aligned}
\left\[\begin{matrix}1 & 0\0 & \alpha\end{matrix}\right]
\end{aligned}
$$

where $$0< \alpha <1$$

**Imperfect quadrature:** Output phases are not in perfect spatial quadrature. Assuming the angle $$\theta\_{res}=0$$ when the rotor excitation winding is aligned with the cosine winding:

$$
\begin{aligned}
\left\[\begin{matrix}R\_{cc} & R\_{cs}\R\_{sc} & R\_{ss}\end{matrix}\right]
\end{aligned}=\begin{aligned}
\left\[\begin{matrix}1 & 0\ \cos \alpha & \sin \alpha\end{matrix}\right]
\end{aligned}
$$

where $$\alpha$$ is the angle between the cosine winding and the sine winding. When $$\alpha = 90°$$, the windings are in perfect quadrature, and the default gain values are recovered.

## **Faults**

One of the windings is not connected due to a fault. In this case, the corresponding gain is equal to zero.

<p align="center"><span class="math">\begin{aligned} \left[\begin{matrix}R_{cc} &#x26; R_{cs}\\R_{sc} &#x26; R_{ss}\end{matrix}\right] \end{aligned}=\begin{aligned} \left[\begin{matrix}1 &#x26; 0\\ 0 &#x26; 0\end{matrix}\right] \end{aligned} \text{ or }\begin{aligned} \left[\begin{matrix}R_{cc} &#x26; R_{cs}\\R_{sc} &#x26; R_{ss}\end{matrix}\right] \end{aligned}=\begin{aligned} \left[\begin{matrix}0 &#x26; 0\\ 0 &#x26; 1\end{matrix}\right] \end{aligned}</span></p>

## **Excitation time shift**

When the excitation signal comes from an external source (one of the analog input channels) the signal can be shifted by a given amount of time.

Number of resolver pole pairs affects the number of electrical turns per mechanical turns.

Resolver sine cosine gains affect the sine (first axis) and cosine (second axis) modulation output. Default values set to 1, 0, 0, 1 make it so the sine modulation has a sine form and the cosine modulation has a cosine form. If set to 0, 1, 1, 0, the sine modulation would have a cosine and the cosine modulation would have a sine form.

Number of pulses per revolution (**Q**<sub>**ppr**</sub>) defines how many times signals A and B pulse between two Z pulses (one full rotation).

Direction of the sensor rotation describes if A leads B (Clockwise) or if B leads A (Counterclockwise)

## Parameters

{% tabs %}
{% tab title="Electrical" %}

<table><thead><tr><th width="180">Parameter</th><th width="310">Description</th><th width="100">Sets Feature</th><th>I/O &#x26; monitoring</th></tr></thead><tbody><tr><td><strong>Motor type</strong></td><td>Type of motor : PMSM (permanent magnet synchronous machine) and BLDC (Brushless DC Machine)</td><td>No</td><td>N/A</td></tr><tr><td><strong>M</strong><sub><strong>conf</strong></sub><strong> Motor configuration type</strong></td><td>Selected: Constant DQ (only available when Motor type PMSM is selected)</td><td>No</td><td>N/A</td></tr><tr><td><strong>R</strong><sub><strong>sabc</strong></sub><strong> Stator resistances</strong></td><td>Stator winding resistances for phases a, b, and c (Ω)</td><td>No</td><td>N/A</td></tr><tr><td><strong>L</strong><sub><strong>s</strong></sub></td><td>Stator inductance value (only available when Motor type BLDC is selected)</td><td>No</td><td>N/A</td></tr><tr><td><strong>L</strong><sub><strong>dq</strong></sub><strong> Stator inductances (DQ)</strong></td><td>d and q axis inductances (only available when Motor type PMSM is selected) (H)</td><td>No</td><td>N/A</td></tr><tr><td><strong>L</strong><sub><strong>0</strong></sub><strong> Zero sequence inductance</strong></td><td><p>Zero Sequence Inductance Value (H)</p><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>If unknown, retain the default value of 1e<sup>15</sup> (H).</p></div></td><td>No</td><td>N/A</td></tr><tr><td><strong>dΦ/dθ Back EMF profile</strong></td><td>Profile of the back EMF, either Sinusoidal (when Motor type PMSM is selected) or Trapezoidal (when Motor type BLDC is selected)</td><td>No</td><td>N/A</td></tr><tr><td><strong>EMF</strong><sub><strong>file</strong></sub><strong> Back EMF profile table</strong></td><td>Field only visible in User defined mode. Allows to import a back EMF resource file.</td><td>No</td><td>N/A</td></tr><tr><td><strong>H Back EMF Flat Area</strong></td><td>Back EMF Flat Area value (only available when Motor type BLDC is selected) °</td><td>No</td><td>N/A</td></tr><tr><td><strong>λ</strong><sub><strong>m1</strong></sub><strong> Permanent magnet flux linkage (Wb)</strong></td><td>Amplitude of the rotor permanent magnet flux.</td><td>No</td><td>N/A</td></tr><tr><td><strong>L</strong><sub><strong>0</strong></sub></td><td>Zero Sequence Inductance Value. If L0 is unknown, retain the default value of 1e15.</td><td>No</td><td>N/A</td></tr><tr><td><strong>pp Number of pole pairs</strong></td><td>Number of machine pole pairs.</td><td>No</td><td>N/A</td></tr><tr><td><strong>dq0 DQ transform</strong></td><td>Selected: Amplitude Invariant</td><td>No</td><td>N/A</td></tr><tr><td><strong>θ</strong><sub><strong>dq0</strong></sub><strong> DQ transform angle</strong></td><td>Selected: A aligned to D</td><td>No</td><td>N/A</td></tr><tr><td><strong>Stator currents, i</strong><sub><strong>s</strong></sub></td><td>Phase currents at stator phases a, b, and c (A)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>Stator currents (DQ), i</strong><sub><strong>sdq</strong></sub></td><td>Currents measured of axis d, q and 0 sequence current (A)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>Stator voltages, V</strong><sub><strong>s</strong></sub></td><td>Phase voltages at stator phases a, b, and c (V)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>Back EMF voltages, B</strong><sub><strong>emf</strong></sub></td><td>Phase-to-neutral back-EMF generated from the permanent magnet flux linkage (V)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>Electrical rotor position, θ</strong><sub><strong>e</strong></sub></td><td>Position of the rotor from 0 to 360 degrees (°)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>R</strong><sub><strong>s</strong></sub><strong> Snubber resistance</strong></td><td>Snubber resistances on phases a, b, and c (Ω)</td><td>No</td><td>N/A</td></tr><tr><td><strong>C</strong><sub><strong>s</strong></sub><strong> Snubber capacitance</strong></td><td>Snubber capacitances on phases a, b, and c (F)</td><td>NO</td><td>N/A</td></tr></tbody></table>
{% endtab %}

{% tab title="Mechanical" %}

<table><thead><tr><th width="180">Parameter</th><th width="310">Description</th><th width="100">Stets feature</th><th width="120">I/O &#x26; Monitoring</th></tr></thead><tbody><tr><td><strong>J Rotor inertia</strong></td><td>Rotor moment of inertia available only in Torque mode (kg·m<sup>2</sup>)</td><td>No</td><td>N/A</td></tr><tr><td><strong>F</strong><sub><strong>s</strong></sub><strong> Static friction torque</strong></td><td>Static friction torque (Nm)</td><td>No</td><td>N/A</td></tr><tr><td><strong>F</strong><sub><strong>v</strong></sub><strong> Viscous friction coefficient</strong></td><td>Viscous friction available only in Torque mode (N·m·s/rad)</td><td>No</td><td>N/A</td></tr><tr><td><strong>ctrl Mechanical control mode</strong></td><td><p>Options: Speed or Torque.</p><p>In <strong>Speed (0) mode</strong>, the mechanical model is bypassed and the speed command is applied directly.<br>In <strong>Torque (1) mode</strong>, the torque command drives the mechanical model to compute speed.</p></td><td>Yes</td><td>From model</td></tr><tr><td><strong>T Torque command</strong></td><td>Torque command to the mechanical model (Nm)</td><td>Yes</td><td>From model</td></tr><tr><td><strong>ω</strong><sub><strong>r0</strong></sub><strong> Initial rotor speed command</strong></td><td>Initial rotor speed setpoint (rpm)</td><td>No</td><td>N/A</td></tr><tr><td><strong>ω</strong><sub><strong>rc</strong></sub><strong> Rotor speed command</strong></td><td>Rotor speed command to the mechanical model (rpm)</td><td>Yes</td><td>From model</td></tr><tr><td><strong>Rotor speed, ω</strong><sub><strong>r</strong></sub></td><td>Mechanical rotor speed (rpm)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>θ</strong><sub><strong>0</strong></sub><strong> Initial rotor angle</strong></td><td>Rotor position at time t = 0 (°)</td><td>No</td><td>N/A</td></tr><tr><td><strong>Rotor angle, θ</strong></td><td>Mechanical rotor angle (0–360°) (°)</td><td>No</td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>Electromagnetic torque T</strong><sub><strong>e</strong></sub></td><td>Torque measured at the rotor (Nm)</td><td> </td><td>To model<br>To AO<br>To SFP<br>To Waveform</td></tr></tbody></table>
{% endtab %}

{% tab title="Resolver" %}

<table><thead><tr><th width="180">Parameter</th><th width="310">Description</th><th width="100">Sets feature</th><th width="120">I/O &#x26; Monitoring</th></tr></thead><tbody><tr><td><strong>Enable resolver Ren</strong></td><td><p><strong>Disable</strong> the resolver.</p><p><strong>Enable</strong> the resolver, the following parameters are displayed.</p></td><td>No</td><td>N/A</td></tr><tr><td><strong>Resolver feedback signals R</strong><sub><strong>sc</strong></sub></td><td>Resolver sine and cosine feedback signals proportional to the angle.</td><td>No</td><td>To model<br>To model<br>To AO<br>To SFP<br>To Waveform</td></tr><tr><td><strong>R</strong><sub><strong>pp</strong></sub><strong> Number of resolver pole pairs</strong></td><td>Resolver pole-pair count.</td><td>No</td><td>N/A</td></tr><tr><td><strong>R</strong><sub><strong>dir</strong></sub><strong> Direction of the sensor rotation</strong></td><td>Options: Clockwise or counterclockwise.</td><td>No</td><td>N/A</td></tr><tr><td><strong>R</strong><sub><strong>θ</strong></sub><strong> Angle offset Δθ (Sensor − Rotor)</strong></td><td>Angle offset between resolver and rotor position (°)</td><td>No</td><td>N/A</td></tr><tr><td><strong>R</strong><sub><strong>k</strong></sub><strong> Resolver sine/cosine gains</strong></td><td>The sine/cosine modulation output sine/cosine component amplitude. Default value are 1, 0, 0 and 1.</td><td>No</td><td>N/A</td></tr><tr><td><strong>E</strong><sub><strong>mod</strong></sub><strong> Excitation mode</strong></td><td>Number of resolver excitation windings.<br>Selected: single (just one excitation signal)</td><td>No</td><td>N/A</td></tr><tr><td><strong>E</strong><sub><strong>type</strong></sub><strong> Excitation source type</strong></td><td><p>Options AC, DC External<br><strong>AC</strong>: generated in FPGA at the specified frequency,</p><p><strong>DC:</strong> single excitation only<br><strong>External</strong> provided from outside the model.</p></td><td>No</td><td>N/A</td></tr><tr><td><strong>E</strong><sub><strong>src1</strong></sub><strong> Excitation source</strong></td><td>External excitation source in External mode.</td><td>No</td><td>From AI</td></tr><tr><td><strong>E</strong><sub><strong>f</strong></sub><strong> Excitation frequency</strong></td><td>Frequency of the excitation when in AC mode (Hz)</td><td>No</td><td>From model</td></tr><tr><td><strong>E</strong><sub><strong>ts</strong></sub><strong> Excitation time shift</strong></td><td>Compensates time offset between the carrier generation input and modulated signal output (s)</td><td>No</td><td>N/A</td></tr></tbody></table>
{% endtab %}

{% tab title="Encoder" %}

<table><thead><tr><th width="180">Parameter</th><th width="310">Description</th><th width="100">Sets feature</th><th>I/O &#x26; Monitoring</th></tr></thead><tbody><tr><td><strong>Enc</strong><sub><strong>en</strong></sub><strong> Enable encoder</strong></td><td><p><strong>Disable</strong> the encoder.</p><p><strong>Enable</strong> the encoder, the following parameters are displayed.</p></td><td>No</td><td>N/A</td></tr><tr><td><strong>Enc</strong><sub><strong>type</strong></sub><strong> Encoder type</strong></td><td>Options : Quadrature or Hall Effect.</td><td>No</td><td>N/A</td></tr><tr><td><strong>A B Z encoder signals Q</strong><sub><strong>ABZ</strong></sub></td><td>Quadrature encoder A, B, and Z signals in Quadrature mode</td><td>No</td><td>To DO</td></tr><tr><td><strong>A B C encoder signals H</strong><sub><strong>ABC</strong></sub></td><td>Hall-effect encoder A, B, and C signals in hall effect mode.</td><td>No</td><td>To DO</td></tr><tr><td><strong>Q</strong><sub><strong>ppr</strong></sub><strong> Number of pulses per revolution</strong></td><td>Number of pulses in one full revolution of the encoder in Quadrature mode.</td><td>No</td><td>N/A</td></tr><tr><td><strong>Q</strong><sub><strong>dir</strong></sub><strong> Direction of the sensor rotation</strong></td><td>Direction in which the sensor is turning, A leads B or B leads A in Quadrature mode.</td><td>No</td><td>N/A</td></tr><tr><td><strong>Q</strong><sub><strong>θ</strong></sub><strong> Angle offset Δθ (Sensor − Rotor)</strong></td><td>Angle offset between the encoder and the rotor position from 0 to 360 degrees in Quadrature mode (°)</td><td>No</td><td>N/A</td></tr><tr><td><strong>Q</strong><sub><strong>rat</strong></sub><strong> Encoder speed ratio</strong></td><td>Sensor-to-mechanical position ratio. Encoder angle = Qrat × machine mechanical angle in Quadrature mode.</td><td>No</td><td>N/A</td></tr><tr><td><strong>H</strong><sub><strong>θ</strong></sub><strong> Hall effect sensor position</strong></td><td>Positions of phases a, b, and c in Hall effect mode (°)</td><td>No</td><td>N/A</td></tr><tr><td><strong>H</strong><sub><strong>rat</strong></sub><strong> Hall effect sensor speed ratio</strong></td><td>Mechanical to encoder ratio. Angle of Encoder = Hrat * machine mechanical angle in Hall effect mode</td><td>No</td><td>N/A</td></tr></tbody></table>
{% endtab %}
{% endtabs %}

{% hint style="info" %}
The I/O type and quantities depend on the selected firmware.
{% endhint %}

### PMSM files parameters

<details>

<summary><strong>How to specify Back EMF parameters in the Back-EMF file</strong></summary>

This block allows you to specify the **Back‑EMF values** by providing a file when the **User‑defined** option is selected. The Back‑EMF parameters must be defined in **JSON format**, and the file must include the following parameters:

| Parameter (JSON key) | Value type    | Unit | Description                                                                                                                            | Example                                                                                  |
| -------------------- | ------------- | ---- | -------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------- |
| **backEmfValues**    | double\[1024] | N/A  | <p>One dimensional array of the back EMF waveform values.<br>The range of values must be from -1 to 1!<br>Needs to be 1024 values!</p> | <p>"backEmfValues": \[<br>-0.0,<br>-0.005,<br>-0.01,<br>\[…]<br>0.01,<br>0.005<br>],</p> |

</details>

## Conserving ports

| Port                 | Description                                                                                                                                                                    |
| -------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Stator terminals (6) | Six electrical conserving ports corresponding to the open-end stator winding terminals. Terminals can be identified by clicking them to view their port identifiers in the UI. |

## Characteristics and limitations

| Characteristic                          | Value                       |
| --------------------------------------- | --------------------------- |
| Variable DQ Mode with saturation tables | Planned for future releases |
| User Defined BEMF Profile               | Planned for future releases |
| Parameter update on the fly             | Planned for future releases |
| Double excitation resolver              | Planned for future releases |
| Power measurement                       | Planned for future releases |
| Power Invariant Transformation          | Planned for future releases |
| “A aligned to Q” Transform Angle        | Planned for future releases |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/ehs/3.7/model-in-schematic-editor/library-blocks-reference/machines-blocks/permanent-magnet-synchronous-machine-3-phase-open-end-winding.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.