> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/ehs/3.7/model-in-schematic-editor/read-error-notifications.md).

# Read Error Notifications

If an error occurs while loading the circuit from <code class="expression">space.vars.cpu\_model\_veristand</code>, review the additional information provided in the error message to identify and resolve the issue. Problems can originate from the Schematic Editor circuit model, the simulator setup, or the eHS configuration.

<figure><img src="https://521571437-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fo99Izmvvw5eHT4ldzI4g%2Fuploads%2Fgit-blob-76f4ca8a72fe310c602b9c98be89c36d9e6a215b%2Fse-ehs-error-code.png?alt=media" alt=""><figcaption></figcaption></figure>

The complete list of error codes and their descriptions is provided below.

## Error notification codes <a href="#errors" id="errors"></a>

| Code    | Description                                                                               | Display message example                                                                                                                                                                                                                                                                                                                                                            |
| ------- | ----------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **100** | No firmware has been selected in the Schematic Editor                                     | Error (100): A firmware should be selected from the circuit editor simulator setup.                                                                                                                                                                                                                                                                                                |
| **101** | Too many scenarios on FPGA (parameter sets)                                               | Error (101): Number of scenarios used on FPGA (6) exceeds the maximum supported for this circuit (5). To support more scenarios use option "use CPU to store and load scenario"                                                                                                                                                                                                    |
| **102** | Empty model                                                                               | Error (102): The model is empty. Please provide some inputs.                                                                                                                                                                                                                                                                                                                       |
| **103** | No measurements in the model                                                              | Error (103): Circuit should contain at least one measurement to be usable.                                                                                                                                                                                                                                                                                                         |
| **104** | Disjoint circuit                                                                          | Error (104): The model shall not be composed of two disjoint circuits when analysis method is Nodal Analysis (eHS Gen4). Circuits composed of multiple separated sub-circuits are not supported in this case.                                                                                                                                                                      |
| **105** | Too many sources                                                                          | Error (105): The total number of sources (17) exceeds the limit (16) supported by the license class x16.                                                                                                                                                                                                                                                                           |
| **106** | Too many switches                                                                         | <p>Error (106): The number of switches (93) exceeds the limit (48) supported by the license class x32. Switches are added by:<br>- Single Switch: 47 units \* 1 switches<br>- Half Bridge: 23 units \* 2 switches</p>                                                                                                                                                              |
| **107** | Too many measurements                                                                     | Error (107): The number of measurements (17) exceeds the limit (16) supported by the license class x16.                                                                                                                                                                                                                                                                            |
| **108** | Too many states                                                                           | Error (108): The number of states (345) exceeds the limit (344) supported by eHS .                                                                                                                                                                                                                                                                                                 |
| **109** | Too many machines                                                                         | Error (109): The maximum number of PMSM DQ (3) exceeds the limit (2) supported by the selected firmware.                                                                                                                                                                                                                                                                           |
| **110** | Wrong file extension for VDQ                                                              | Error (110): Unsupported resource file extension: jpeg. Variable DQ only supports JMAG (.rtt) and ANSYS (.txt) formats.                                                                                                                                                                                                                                                            |
| **111** | Machine resolver external excitation parameters mismatch in the Schematic Editor          | Error (111): The machine 'scim1' has its parameter Excitation Type assigned to external but no Analog Input has been assigned to the parameter Excitation Source.                                                                                                                                                                                                                  |
| **112** | No resource file found for a machine in VDQ or SH mode                                    | Error (112): The component 'pmsm1' parameter Resource File cannot be found. Please provide some input in the "Motor Configuration" field in the Schematic Editor model.                                                                                                                                                                                                            |
| **113** | BLDC not supported with the selected firmware                                             | Error (113): The current version of the firmware does not support the BLDC machine.                                                                                                                                                                                                                                                                                                |
| **114** | Firmware resource not found                                                               | Error (114): The model configuration requires a firmware resource of type PMSM / BLDC, but none was found in the selected firmware.                                                                                                                                                                                                                                                |
| **115** | Too many CPU driven gates                                                                 | Error(115): The number of gates driven via the CPU (73) exceeds the limit (72) supported by the selected firmware.                                                                                                                                                                                                                                                                 |
| **116** | Missing parameters in the PMSM VDQ configuration file                                     | Error (116): Error parsing the PMSM VDQ configuration file. Please update your file, following parameters are missing: DqTransformAngleOffset.                                                                                                                                                                                                                                     |
| **117** | Negative time step for eHS                                                                | Error(117): The time step of eHS must be positive, but '-3.26' was found.                                                                                                                                                                                                                                                                                                          |
| **118** | User time step is too small                                                               | Error(118): Unable to achieve the requested user time step of 200 ns. The minimum achievable time step for this circuit is 210 ns. (eHS cannot achieve the desired time step).                                                                                                                                                                                                     |
| **119** | User time step is too big                                                                 | Error(119): Unable to achieve the requested user time step of 4000 ns. The minimum achievable time step for this circuit is 2500 ns. (eHS cannot achieve the desired time step).                                                                                                                                                                                                   |
| **120** | Circuit with a 'PMSM Spatial Harmonics' block requires a time step (Ts) multiple of 50 ns | Error(120): Circuit with a 'PMSM Spatial Harmonics' block requires a time step (Ts) multiple of 50 ns.                                                                                                                                                                                                                                                                             |
| **121** | Too many AC sources                                                                       | Error (121): The number of AC sources (40) exceeds the limit (32) supported by the selected firmware.                                                                                                                                                                                                                                                                              |
| **122** | Circuit too large                                                                         | Error (122): The circuit exceeds the number of computation unit available. Try to reduce the number of inputs, outputs, measurements or find equivalent circuit for group of components.                                                                                                                                                                                           |
| **123** | Circuit validation error                                                                  | <p>Error (123): The circuit validation has failed. Errors during circuit analysis:<br>- The capacitor c2 cannot be connected in parallel with voltage source vsrc2.<br>- The inductor l2 cannot be connected in series with current source isrc1.</p>                                                                                                                              |
| **124** | Unsupported component                                                                     | Error (124): Unsupported component sw1 (SW) with eHS Gen 5 solver.                                                                                                                                                                                                                                                                                                                 |
| **125** | User time step is not multiple of the smallest granularity                                | Error (125): Model time step specified in the Schematic Editor (206ns) should be a multiple of the smallest circuit time step granularity (50ns).                                                                                                                                                                                                                                  |
| **126** | Unsupported firmware license class                                                        | Error (126): Unsupported firmware license class for eHS Gen5: x64.                                                                                                                                                                                                                                                                                                                 |
| **127** | Not enough states                                                                         | Error (127): No state found in the circuit. Circuit should contain at least one state (Inductor, Capacitor, Transformer).                                                                                                                                                                                                                                                          |
| **128** | Incompatible Version                                                                      | Error (128): The Schematic Editor version 2.8.3 in use is not compatible with eFPGASIM version 2.9.1. Please install Schematic Editor version 2.9.1 or higher.                                                                                                                                                                                                                     |
| **129** | Incompatible Solver Settings *(Deprecated)*                                               | Error (129): The selected solver settings Analysis Method Nodal Analysis(eHS Gen 4) is not compatible with the firmware VC707\_2-EX-0001-3\_3\_1\_790-eHSx128\_Gen5\_IOConfig1-F5-4E.                                                                                                                                                                                              |
| **131** | Database Unavailable                                                                      | Error (131): OPAL-RT Unified Database is unavailable. Please verify your Schematic Editor installation.                                                                                                                                                                                                                                                                            |
| **132** | Too many non-linear components                                                            | Error (132): The number of non-linear components (70) exceeds the limit (64) supported by the selected firmware.                                                                                                                                                                                                                                                                   |
| **133** | Invalid parameters for Surge Arrester                                                     | Error (133): Surge arrester sa1 has invalid parameters (it must have k2 > k1, k2 > k3 and alpha1 > alpha2 > alpha3).                                                                                                                                                                                                                                                               |
| **134** | Invalid Parameter Value compare to the Bounding Value                                     | Error (134): The value v1 of the parameter p1 is invalid. The value must be (*greater than or equal to \| greater than \| less than or equal to \| less than*) to v2.                                                                                                                                                                                                              |
| **135** | Integer Type Parameter Value                                                              | Error (135): The value v1 of the parameter p1 is invalid. The value must be an integer.                                                                                                                                                                                                                                                                                            |
| **136** | Unsupported scenarios for such a big circuit                                              | Error (136): The circuit size exceeds the number of computation unit available to support multiple scenarios (529/512).                                                                                                                                                                                                                                                            |
| **137** | Invalid table parameters                                                                  | Error (137): The values for parameter IV Table voltages values are invalid. The values need to be strictly monotonically increasing. Please refer to page "Surge Arrester IV parameters file" in official documentation for further details.                                                                                                                                       |
| **138** | Unsupported feature                                                                       | Error (138): The feature Scenario from CPU is unsupported with current version 0.0.0 of eHS, needs 1.0.0 or higher. Update to a firmware which contains a newer version of the block to use this feature.                                                                                                                                                                          |
| **139** | Malformed JSON                                                                            | Error (139): Cannot read resource file, JSON file had following formatting issue: Unterminated array at line 1 column 23 path $.backEmfValues\[1]                                                                                                                                                                                                                                  |
| **140** | Ill-conditioned matrix                                                                    | <p>Error (140): Unable to process circuit with the specified parameters, singularity while trying to invert matrix. To remedy:<br>1. If possible, try changing discretization method to Backward Euler.<br>2. Try adding high value resistances between primary and secondary of transformers.<br>3. Try adjusting the relaxation parameter of switches and bridge components.</p> |
| **141** | Too many TSB switches *(deprecated)*                                                      | Error (141): The total number of switches (100) added by Half Bridges (2), Single Phase Cycloconverters (8) & 3-Lvl Arms (4) exceeds the limit supported by eHS Gen 5 x128. The maximum number of Half Bridge & Single Phase Cycloconverter switches allowed in the circuit is 128.                                                                                                |
| **142** | Too many low latency measurements                                                         | Error (142): "The number of low latency external measurements (140) exceeds the limit supported by eHS Gen 5 x128. "+ "The maximum number of low latency external measurements allowed in the circuit is 128. Try to reduce the number of \[Surge Arrester] components in your circuit."                                                                                           |
| **143** | Unable to evaluate expression                                                             | <p>Error (143): A parameter has an expression value that could not be resolved.<br>• Block 'vsrc1'<br>• Unable to evaluate 'dc\_value \* 0.5' in Matlab</p>                                                                                                                                                                                                                        |
| **144** | Outdated feature                                                                          | Error (144): The feature "eHS Gen 5" has been improved and requires to update eHS Gen 5 to version 1.2.0. Update to a firmware which contains a newer version of the block to use this feature.                                                                                                                                                                                    |
| **145** | Unable to evaluate smallest Ts                                                            | Error (145): The Solver Strategy "Smallest Time Step" can't be apply on this circuit. Using the "Lowest Latency" strategy in the Schematic Editor will solve this issue but will increase the Time step of the circuit."                                                                                                                                                           |
| **146** | Model has unsaved changes *(deprecated)*                                                  | Error (146): The Schematic Editor model has unsaved changes. Save the model before loading the circuit.                                                                                                                                                                                                                                                                            |
| **147** | Model uses a reserved name as an input or output                                          | <p>Error (147): The name “reset” is reserved for a utility pin. Change the name in the circuit model.<br>• Reserved names: “parameter\_set\_id”, “parameter\_set\_output\_id”, “reset”</p>                                                                                                                                                                                         |
| **148** | Malformed Pun file                                                                        | <p>Error (148): Cannot read resource file “Pun File”. Parser had the following issue:<br>Cannot find ‘poles impedance’ in ' 3.804409763194375955D-07 1.494890152734087937D-05 3.348494529259195805D-05 '<br>Invalid propagation section<br>Invalid mode section 1</p>                                                                                                              |
| **149** | Frequency dependent line number of phases mismatch with Pun file                          | Error (149): Frequency dependent line “fd1” has 3 phases, which doesn’t match the configuration file “Pun File” that has 6.                                                                                                                                                                                                                                                        |
| **150** | Too many frequency dependent line phases                                                  | Error (150): The number of Frequency Dependent Line total phases (18) exceeds the limit (16) supported by the selected firmware.                                                                                                                                                                                                                                                   |
| **151** | Time step too high for current frequency dependent lines                                  | <p>Error (151): The current time step (4000 ns) is invalid with the current frequency dependent lines.<br>Minimum time step is 10 ns, maximum time step is 2225 ns.<br>You can try splitting the longest frequency dependent line in smaller segments.</p>                                                                                                                         |
| **152** | Schematic Editor connection to unsupported parameter in ioconf                            | Error (152): Trying to connect signal "Omega\_r" of component "pmsm1" to CPU or IO but no matching signal information was found in selected firmware description. Regenerate ioconf to make sure firmware description file is up to date with features available in Schematic Editor.                                                                                              |
| **153** | Too many single switches                                                                  | Error (153): The total number of single switches (129) exceeds the limit (128) supported by the selected firmware.                                                                                                                                                                                                                                                                 |
| **154** | Too many TSB Switches                                                                     | <p>Error (154): The total number of switches with interpolation (66) exceeds the limit (64) supported by the selected firmware. Those switches are added by:<br>• Half Bridge: 33 units \* 2 switches</p>                                                                                                                                                                          |
| **155** | Remote bitstreams unsupported with Sfunction drivers                                      | Error (155): MuSE remote bitstreams cannot be used with the Sfunction workflow.                                                                                                                                                                                                                                                                                                    |
| **156** | Remote bitstreams unsupported with Opal board drivers                                     | Error (156): MuSE remote bitstreams cannot be used with the OpalBoard workflow.                                                                                                                                                                                                                                                                                                    |
| **157** | Incompatible machines types                                                               | <p>Error (157): Cannot assign all Machines to available firmware resources:<br>•<br>1 sets of either<br>• Up to 4x 3-phase open-end winding PMSM<br>• Up to 2x 6-phase PMSM<br>• 1 12-phase PMSM</p>                                                                                                                                                                               |
| **158** | Too many measurements for firmware                                                        | Error (158): The total number of measurements (129) exceeds the limit (128) supported by the selected firmware.                                                                                                                                                                                                                                                                    |
| **159** | Too many sources for firmware                                                             | Error (159): The total number of sources (129) exceeds the limit (128) supported by the selected firmware.                                                                                                                                                                                                                                                                         |
| **160** | Too many states for firmware                                                              | Error (160): The total number of states (345) exceeds the limit (344) supported by the selected firmware.                                                                                                                                                                                                                                                                          |
| **161** | File does not exist                                                                       | Error (161): File C:/not/a/real/path/to/file.ehs3 does not exist.                                                                                                                                                                                                                                                                                                                  |
| **162** | Can’t set gain or offset from CPU with AOMR V2                                            | <p>Error (162): CPU inputs cannot be used to configure the gain and/or offset of Analog Outputs using the selected firmware.<br>Select a firmware that includes AOMR V3, or disconnect the following parameters from the CPU:<br>connectable\_1\_GAIN</p>                                                                                                                          |
| **163** | No Auto decoupling latency for Half Line FPGA to FPGA                                     | Error (163): The auto decoupling latency is unavailable for a half line FPGA to FPGA component                                                                                                                                                                                                                                                                                     |
| **164** | Invalid transformer parameters                                                            | Error (164): The transformer xfmr1 has ideal magnetization with no ideal winding. Due to modeling constraints, you must either turn off ideal magnetization, or make at least one winding ideal.                                                                                                                                                                                   |
| **168** | Minimum greater than maximum in connection parameter                                      | Error (168): Minimum value 4.00 for connection Slot 1A Channel 00 is greater than maximum 5.00 Change minimum and or maximum so that the maximum is greater than the minimum.                                                                                                                                                                                                      |
| **169** | HSCS decoupling block connection error                                                    | Error (169): Left or right HSCS decoupling block ports must be connected to power ports towards eHS.                                                                                                                                                                                                                                                                               |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/ehs/3.7/model-in-schematic-editor/read-error-notifications.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.