> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/ehs/model-in-schematic-editor/library-blocks-reference/transformer-blocks/single-phase-three-winding-transformer.md).

# Single Phase Three Winding Transformer

## Description

<figure><img src="https://3212678799-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FABuoXNYgvaoO7wIe3bfO%2Fuploads%2Fgit-blob-6872e3236712333d7cf6ffc6ecbd5f1fad2145b2%2FSE_sp3windingtransfo.png?alt=media" alt="" width="124"><figcaption></figcaption></figure>

The **Single Phase Three Winding Transformer** block implements a three-winding transformer (1 primary, 1 secondary, 1 tertiary) and models three coupled windings on the same core. The magnetization inductance **L**<sub>**m**</sub> is linear and modeled on the primary side of the transformer. Core losses are modeled as **R**<sub>**m**</sub> resistance located on the primary side of the transformer.

### Limitation

When the transformer magnetization is set to **ideal**, at least one transformer winding must also be configured as ideal; otherwise, the model will fail to compile. Additionally, certain circuit topologies are incompatible with ideal magnetization. For example, a fully ideal transformer with inductances placed in series with all winding branches cannot compile correctly. In such cases, possible solutions include reintroducing a magnetization resistance or, if that is not feasible, relocating inductive or capacitive components so they appear on only one side of the transformer.

## Parameters

### In eHS circuit

<figure><img src="https://3212678799-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FABuoXNYgvaoO7wIe3bfO%2Fuploads%2Fgit-blob-fa68ab2ebadda6b7f0fb30f28927bba03b2a3bdf%2FSE_sp3windingtransfoparam.png?alt=media" alt=""><figcaption></figcaption></figure>

{% tabs %}
{% tab title="Primary winding (1)" %}

| Parameter                                      | Description                                                                                                          | Sets feature | I/O & Monitoring |
| ---------------------------------------------- | -------------------------------------------------------------------------------------------------------------------- | ------------ | ---------------- |
| **Ideal**                                      | When **enabled**, primary leakage resistance and inductance are neglected. When **disabled**, they can be specified. | No           | N/A              |
| **Nominal voltage (V**<sub>**1**</sub>**)**    | The nominal voltage V, in volts RMS, of the primary winding.                                                         | Yes          | N/A              |
| **Resistance (R**<sub>**1**</sub>**)**         | The resistance, in ohms, of the primary winding.                                                                     | Yes          | N/A              |
| **Leakage inductance (L**<sub>**1**</sub>**)** | The leakage inductance, in henries, of the primary winding.                                                          | Yes          | N/A              |
| **Initial current (I**<sub>**1**</sub>**)**    | The initial current A, in amperes, of the primary winding.                                                           | No           | N/A              |
| {% endtab %}                                   |                                                                                                                      |              |                  |

{% tab title="Secondary winding (2)" %}

| Parameter                                      | Description                                                                                                          | Sets feature | I/O & Monitoring |
| ---------------------------------------------- | -------------------------------------------------------------------------------------------------------------------- | ------------ | ---------------- |
| **Ideal**                                      | When **enabled**, primary leakage resistance and inductance are neglected. When **disabled**, they can be specified. | No           | N/A              |
| **Nominal voltage (V**<sub>**2**</sub>**)**    | The nominal voltage V, in volts RMS, of the secondary winding.                                                       | Yes          | N/A              |
| **Resistance (R**<sub>**2**</sub>**)**         | The resistance, in ohms, of the secondary winding.                                                                   | Yes          | N/A              |
| **Leakage inductance (L**<sub>**2**</sub>**)** | The leakage inductance, in henries, of the secondary winding.                                                        | Yes          | N/A              |
| **Initial current (I**<sub>**2**</sub>**)**    | The initial current A, in amperes, of the secondary winding.                                                         | No           | N/A              |
| {% endtab %}                                   |                                                                                                                      |              |                  |

{% tab title="Tertiary winding (3)" %}

| Parameter                                      | Description                                                                                                          | Sets feature | I/O & Monitoring |
| ---------------------------------------------- | -------------------------------------------------------------------------------------------------------------------- | ------------ | ---------------- |
| **Ideal**                                      | When **enabled**, primary leakage resistance and inductance are neglected. When **disabled**, they can be specified. | No           | N/A              |
| **Nominal voltage (V**<sub>**3**</sub>**)**    | The nominal voltage V, in volts RMS, of the tertiary winding.                                                        | Yes          | N/A              |
| **Resistance (R**<sub>**3**</sub>**)**         | The resistance, in ohms, of the tertiary winding.                                                                    | Yes          | N/A              |
| **Leakage inductance (L**<sub>**3**</sub>**)** | The leakage inductance, in henries, of the tertiary winding.                                                         | Yes          | N/A              |
| **Initial current (I**<sub>**3**</sub>**)**    | The initial current A, in amperes, of the tertiary winding.                                                          | No           | N/A              |
| {% endtab %}                                   |                                                                                                                      |              |                  |

{% tab title="Magnetization" %}

| Parameter                                   | Description                                                                                                                                 | Sets feature | I/O & Monitoring |
| ------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------- | ------------ | ---------------- |
| **Ideal**                                   | When this option is enabled, the core resistance and core inductance are set to very high values, so the magnetization branch is neglected. | No           | N/A              |
| **Resistance (R**<sub>**m**</sub>**)**      | The resistance and inductance simulating the core active and reactive losses.                                                               | Yes          | N/A              |
| **Inductance (L**<sub>**m**</sub>**)**      | The resistance and inductance simulating the core active and reactive losses.                                                               | Yes          | N/A              |
| **Initial current (I**<sub>**m**</sub>**)** | The initial current A, in amperes, of the magnetizing inductance.                                                                           | No           | N/A              |
| {% endtab %}                                |                                                                                                                                             |              |                  |
| {% endtabs %}                               |                                                                                                                                             |              |                  |

### In HSCS circuit

<figure><img src="https://3212678799-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FABuoXNYgvaoO7wIe3bfO%2Fuploads%2Fgit-blob-bc253468231a11374ed709e2eecf14f23bf8cbe5%2FSE_sp3windingtransfoparam-hscs.png?alt=media" alt=""><figcaption></figcaption></figure>

{% tabs %}
{% tab title="Primary winding (1)" %}

| Parameter                                      | Description                                                                                                          | Sets feature | I/O & Monitoring                                         |
| ---------------------------------------------- | -------------------------------------------------------------------------------------------------------------------- | ------------ | -------------------------------------------------------- |
| **Ideal**                                      | When **enabled**, primary leakage resistance and inductance are neglected. When **disabled**, they can be specified. | No           | N/A                                                      |
| **Nominal voltage (V**<sub>**1**</sub>**)**    | The nominal voltage V, in volts RMS, of the primary winding.                                                         | Yes          | N/A                                                      |
| **Resistance (R**<sub>**1**</sub>**)**         | The resistance, in ohms, of the primary winding.                                                                     | Yes          | N/A                                                      |
| **Leakage inductance (L**<sub>**1**</sub>**)** | The leakage inductance, in henries, of the primary winding.                                                          | Yes          | N/A                                                      |
| **Initial current (I**<sub>**1**</sub>**)**    | The initial current A, in amperes, of the primary winding.                                                           | No           | N/A                                                      |
| **Current (I**<sub>**out1**</sub>**)**         | The electrical current, in amperes, flowing through the primary winding of the transformer.                          | No           | <p>To CPU model<br>To Analog Output<br>To SFP Output</p> |
| {% endtab %}                                   |                                                                                                                      |              |                                                          |

{% tab title="Secondary winding (2)" %}

| Parameter                                      | Description                                                                                                          | Sets feature | I/O & Monitoring                                         |
| ---------------------------------------------- | -------------------------------------------------------------------------------------------------------------------- | ------------ | -------------------------------------------------------- |
| **Ideal**                                      | When **enabled**, primary leakage resistance and inductance are neglected. When **disabled**, they can be specified. | No           | N/A                                                      |
| **Nominal voltage (V**<sub>**2**</sub>**)**    | The nominal voltage V, in volts RMS, of the secondary winding.                                                       | Yes          | N/A                                                      |
| **Resistance (R**<sub>**2**</sub>**)**         | The resistance, in ohms, of the secondary winding.                                                                   | Yes          | N/A                                                      |
| **Leakage inductance (L**<sub>**2**</sub>**)** | The leakage inductance, in henries, of the secondary winding.                                                        | Yes          | N/A                                                      |
| **Initial current (I**<sub>**2**</sub>**)**    | The initial current A, in amperes, of the secondary winding.                                                         | No           | N/A                                                      |
| **Current (I**<sub>**out2**</sub>**)**         | The electrical current, in amperes, flowing through the secondary winding of the transformer.                        | No           | <p>To CPU model<br>To Analog Output<br>To SFP Output</p> |
| {% endtab %}                                   |                                                                                                                      |              |                                                          |

{% tab title="Tertiary winding (3)" %}

| Parameter                                      | Description                                                                                                          | Sets feature | I/O & Monitoring                                         |
| ---------------------------------------------- | -------------------------------------------------------------------------------------------------------------------- | ------------ | -------------------------------------------------------- |
| **Ideal**                                      | When **enabled**, primary leakage resistance and inductance are neglected. When **disabled**, they can be specified. | No           | N/A                                                      |
| **Nominal voltage (V**<sub>**3**</sub>**)**    | The nominal voltage V, in volts RMS, of the tertiary winding.                                                        | Yes          | N/A                                                      |
| **Resistance (R**<sub>**3**</sub>**)**         | The resistance, in ohms, of the tertiary winding.                                                                    | Yes          | N/A                                                      |
| **Leakage inductance (L**<sub>**3**</sub>**)** | The leakage inductance, in henries, of the tertiary winding.                                                         | Yes          | N/A                                                      |
| **Initial current (I**<sub>**3**</sub>**)**    | The initial current A, in amperes, of the tertiary winding.                                                          | No           | N/A                                                      |
| **Current (I**<sub>**out3**</sub>**)**         | The electrical current, in amperes, flowing through the tertiary winding of the transformer.                         | No           | <p>To CPU model<br>To Analog Output<br>To SFP Output</p> |
| {% endtab %}                                   |                                                                                                                      |              |                                                          |

{% tab title="Magnetization" %}

| Parameter                                   | Description                                                                                                                                 | Sets feature | I/O & Monitoring                                         |
| ------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------- | ------------ | -------------------------------------------------------- |
| **Ideal**                                   | When this option is enabled, the core resistance and core inductance are set to very high values, so the magnetization branch is neglected. | No           | N/A                                                      |
| **Resistance (R**<sub>**m**</sub>**)**      | The resistance and inductance simulating the core active and reactive losses.                                                               | Yes          | N/A                                                      |
| **Inductance (L**<sub>**m**</sub>**)**      | The resistance and inductance simulating the core active and reactive losses.                                                               | Yes          | N/A                                                      |
| **Initial current (I**<sub>**m**</sub>**)** | The initial current A, in amperes, of the magnetizing inductance.                                                                           | No           | N/A                                                      |
| **Current (I**<sub>**out1**</sub>**)**      | The magnetization current, in amperes.                                                                                                      | No           | <p>To CPU model<br>To Analog Output<br>To SFP Output</p> |
| {% endtab %}                                |                                                                                                                                             |              |                                                          |
| {% endtabs %}                               |                                                                                                                                             |              |                                                          |

## Conserving ports

| Port   | Description   |
| ------ | ------------- |
| **p1** | Positive port |
| **n1** | Negative port |
| **p2** | Positive port |
| **n2** | Negative port |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/ehs/model-in-schematic-editor/library-blocks-reference/transformer-blocks/single-phase-three-winding-transformer.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.