> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/configure-ios/analog-digital-and-sfp-ios/opal-rt-board-workflow/analog-and-resolver-configuration.md).

# Analog & Resolver Configuration

This page describes the **OPAL‑RT Board** configuration for **analog** sections, which define how physical analog I/O modules are connected to and used by the simulation. Available options and behaviors depend on the installed hardware and the **supplied** **bitstream**.

## Analog out I/O section

In the **I/O Interface Configuration** window, click **SlotXX - Analog out** to view and configure its parameters.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-563dfea2f65eada96f3e4fdeb3aac631654ebeb9%2Fimage%20(14).png?alt=media" alt=""><figcaption></figcaption></figure>

<table><thead><tr><th width="165">Parameter</th><th>Value (Description)</th></tr></thead><tbody><tr><td><strong>Description</strong></td><td>Read‑only field describing the <strong>electrical characteristics</strong> of the slot, including signal nature and electrical constraints defined by the installed I/O module.</td></tr><tr><td><strong>Functionality</strong></td><td>Read‑only field specifying the <strong>type of I/O signals</strong> supported by the slot and their <strong>direction</strong> (input, output, or bidirectional).</td></tr><tr><td><strong>I/O type</strong></td><td>Read‑only field identifying the <strong>I/O module</strong> installed in the slot. This identifier is used by the driver to apply the correct configuration and compatibility rules.</td></tr><tr><td><strong>Voltage range</strong></td><td><p>Selects the voltage range applied <strong>globally to all 16 channels</strong> of the Analog Output module.<br>Available options are <strong>±16 V</strong>, <strong>±10 V</strong>, and <strong>±5 V</strong>.</p><p>Output values exceeding the selected range are saturated to the corresponding limits. The full <strong>16‑bit DAC resolution</strong> is preserved for all ranges and always spans the selected voltage range (for example, a 20 V span when using ±10 V).</p></td></tr><tr><td><strong>Maximum sampling rate</strong></td><td>Selects the desired sampling rate from the list of available hardware‑supported choices.</td></tr></tbody></table>

Then, click **Channels 0 - 7** or **Channels 8 - 15** to configure the corresponding subsection.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-0c4902633c7a3f6b0f409377d86c516ac418ce54%2Fimage%20(15).png?alt=media" alt=""><figcaption></figcaption></figure>

### Analog out subsection

<table><thead><tr><th width="150">Parameter</th><th>Value (Description)</th></tr></thead><tbody><tr><td><strong>Enable</strong></td><td><p><strong>Checked:</strong> Exposes the analog output <strong>Channel</strong> <strong>xx</strong> connectable points for the selected subsection. These connectable points can then be connected to the model and used to transmit signals <strong>from the model</strong> during execution.</p><p><strong>Unchecked:</strong> Analog signal transmission for the selected subsection is disabled, and no connectable points are exposed.</p></td></tr></tbody></table>

|

{% hint style="info" %}
If additional configuration parameters are displayed, the bitstream supports an older, non‑recommended workflow that is not documented in detail; the default values should be left unchanged.
{% endhint %}

### Resolver out subsection

A subsection may be configured in the bitstream to operate in **Resolver out** mode, in which case it is dedicated exclusively to two-pole resolver signal generation. In this mode, the physical module **generates** **carrier‑modulated sine and cosine signals** based on the **Speed** provided by the simulation. The availability of this mode depends entirely on the bitstream supplied with the system. Refer to the **System Description Document** provided with your order for connector pin assignments.

<table><thead><tr><th width="150">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Enable</strong></td><td><strong>Checked:</strong> Exposes the <strong>Speed</strong> connectable point for each resolver in the selected subsection. This connectable point can then be connected to the model allowing to control the speed <strong>from the model</strong> during execution.<br><strong>Unchecked:</strong> Transmission for the selected subsection is disabled, and no connectable points are exposed.</td></tr><tr><td><strong>Type</strong></td><td>Read‑only field indicating the I/O signal type configured in the bitstream for this subsection: <strong>Resolver Out</strong>.</td></tr><tr><td><strong>Carrier 1 Select Mode</strong></td><td><strong>Internal</strong>: The FPGA generates the carrier wave for the <strong>first resolver</strong> in the subsection and exposes the <strong>Carrier Frequency</strong> and <strong>Carrier Amplitude</strong> connectable points for run‑time control <strong>from the model</strong> during execution. The carrier frequency is specified in hertz (Hz) with a range of 0 to 95 000 Hz, and the carrier amplitude is specified in volts (V) with a range of 0 to 15 V.<br><strong>External:</strong> The carrier wave for the <strong>first resolver</strong> in the subsection is provided by an external device.</td></tr><tr><td><strong>Carrier 2 Select Mode</strong></td><td><strong>Internal</strong>: The FPGA generates the carrier wave for the <strong>second resolver</strong> in the subsection and exposes the <strong>Carrier Frequency</strong> and <strong>Carrier Amplitude</strong> connectable points for run‑time control <strong>from the model</strong> during execution. The carrier frequency is specified in hertz (Hz) with a range of 0 to 95 000 Hz, and the carrier amplitude is specified in volts (V) with a range of 0 to 15 V.<br><strong>External:</strong> The carrier wave for the <strong>second resolver</strong> in the subsection is provided by an external device.</td></tr></tbody></table>

## Analog in I/O section

In the **I/O Interface Configuration** window, click **SlotXX - Analog in** to view its read-only parameters. Then, click **Channels 0–7** or **Channels 8–15** to configure the corresponding subsection.

### Analog in subsection

<table><thead><tr><th width="150">Parameter</th><th>Value (Description)</th></tr></thead><tbody><tr><td><strong>Enable</strong></td><td><p><strong>Checked:</strong> Exposes the analog input <strong>Channel</strong> <strong>xx</strong> connectable points for the selected subsection. These connectable points can then be connected to the model to input the analog signals <strong>into the model</strong> during execution.</p><p><strong>Unchecked:</strong> Analog signal reception for the selected subsection is disabled, and no connectable points are exposed.</p></td></tr></tbody></table>

### Synchronized analog in (RCP) subsection

A subsection may be configured in the bitstream to operate in **Synchronized analog in** mode, in which case it is dedicated to synchronized analog input acquisition. In this mode, the physical module acquires analog input signals at a rate synchronized by a PWM signal generated by supported digital output modules. The availability of this mode depends entirely on the bitstream supplied with the system.

<table><thead><tr><th width="185">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>PWM group</strong></td><td>Selects the channel group that outputs PWM signals and can be used to synchronize analog input acquisition. Each group contains 8 channels.</td></tr><tr><td><strong>PWM source</strong></td><td>Specifies the channel that provides the PWM synchronization signal. All analog input channels in the same slot are synchronized to this channel.</td></tr><tr><td><strong>PWM trigger type</strong></td><td>Defines when analog input acquisition occurs within the PWM period. Options: <strong>Beginning</strong> (start of the period), <strong>Middle</strong> (midpoint of the period), or <strong>Both</strong> (at both the beginning and midpoint).</td></tr><tr><td><strong>Enable</strong></td><td><p><strong>Checked:</strong> Exposes the analog input <strong>Channel</strong> <strong>xx</strong> connectable points for the selected subsection. These connectable points can then be connected to the model to input the analog signals <strong>into the model</strong> during execution.</p><p><strong>Unchecked:</strong> Analog signal reception for the selected subsection is disabled, and no connectable points are exposed.</p></td></tr></tbody></table>

### Resolver in subsection

A subsection may be configured in the bitstream to operate in **Resolver in** mode, in which case it is dedicated exclusively to receiving resolver signals. In this mode, the physical module **receives** carrier‑modulated sine and cosine signals and provides **Speed** and **Angle** to the simulation. The availability of this mode depends entirely on the bitstream supplied with the system. Refer to the **System Description Document** provided with your order for connector pin assignments.

<table><thead><tr><th width="175">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Enable</strong></td><td><strong>Checked:</strong> Exposes the <strong>Speed</strong> and <strong>Angle</strong> connectable points for each resolver in the selected subsection. These connectable points can then be connected to the model to input the speed and angle <strong>into the model</strong> during execution.<br><strong>Unchecked:</strong> Reception for the selected subsection is disabled, and no connectable points are exposed.</td></tr><tr><td><strong>Type</strong></td><td>Read‑only field indicating the I/O signal type configured in the bitstream for this subsection: <strong>Resolver In</strong>.</td></tr><tr><td><strong>Calibration mode</strong></td><td><strong>Checked:</strong> Enables calibration mode for the selected resolver and exposes all its parameters as connectable points instead of being applied at load time. These connectable points can then be connected to the model and controlled <strong>from the model</strong> during execution. This mode is intended for calibration purposes only, as it uses slower FPGA‑CPU communication and is not suitable for high‑performance simulation.<br><strong>Unchecked:</strong> Parameters are defined during configuration and applied at initialization.</td></tr><tr><td><strong>Damping factor (Ksi)</strong></td><td>Specifies the filter damping factor.</td></tr><tr><td><strong>Natural frequency (ω₀) [Hz]</strong></td><td>Specifies the filter natural frequency.</td></tr><tr><td><strong>Use internal carrier for demodulation</strong></td><td><strong>Checked:</strong> Generates an internal carrier (internal carrier parameters exposed).<br><strong>Unchecked:</strong> Uses an external carrier (external carrier parameters exposed).</td></tr><tr><td><strong>Expected external carrier amplitude [V]</strong></td><td>Amplitude of the received carrier. Range: 0 to 16 V. <em>(Exposed when internal carrier is disabled)</em></td></tr><tr><td><strong>Expected external carrier offset [V]</strong></td><td>Offset of the received carrier. Range: −16 to 16 V. <em>(Exposed when internal carrier is disabled)</em></td></tr><tr><td><strong>Internal carrier delay [s]</strong></td><td>Delay between the internal carrier and resolver signals. Range: 0 to 20 µs. <em>(Exposed when internal carrier is enabled)</em></td></tr><tr><td><strong>Internal carrier frequency [Hz]</strong></td><td>Frequency of the internally generated carrier. Range: 0.01 to 90,000 Hz. <em>(Exposed when internal carrier is enabled)</em></td></tr><tr><td><strong>Generated carrier amplitude [V]</strong></td><td>Amplitude of the internally generated carrier output. Range: 0 to 16 V. <em>(Exposed when internal carrier is enabled)</em></td></tr><tr><td><strong>Generated carrier offset [V]</strong></td><td>Offset of the internally generated carrier output. Range: −16 to 16 V. <em>(Exposed when internal carrier is enabled)</em></td></tr><tr><td><strong>Sine amplitude [V]</strong></td><td>Amplitude of the resolver sine signal. Range: 0 to 16 V.</td></tr><tr><td><strong>Sine offset [V]</strong></td><td>Offset of the resolver sine signal. Range: −16 to 16 V.</td></tr><tr><td><strong>Cosine amplitude [V]</strong></td><td>Amplitude of the resolver cosine signal. Range: 0 to 16 V.</td></tr><tr><td><strong>Cosine offset [V]</strong></td><td>Offset of the resolver cosine signal. Range: −16 to 16 V.</td></tr></tbody></table>

## Mixed analog I/O section

In the **I/O Interface Configuration** window, click **SlotXX - Analog out** to view and configure its parameters. Then, click **Channels 0–7** or **Channels 8–15** to configure the corresponding subsection.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-3aa25d860da2c57d7e43f11a834aae6357f75874%2FDR-hyp-opalboard-mixed.png?alt=media" alt=""><figcaption></figcaption></figure>

<table><thead><tr><th width="150">Parameter</th><th>Value (Description)</th></tr></thead><tbody><tr><td><strong>Enable</strong></td><td><p><strong>Checked:</strong> Exposes the analog <strong>Channel</strong> <strong>xx</strong> connectable points for the selected subsection. These connectable points can then be connected to the model to input the analog signals <strong>into the model</strong> during execution when the subsection is <strong>(input)</strong> or, to transmit signals <strong>from the model</strong> during execution when subsection is <strong>(output)</strong>.</p><p><strong>Unchecked:</strong> Analog signals for the selected subsection are disabled, and no connectable points are exposed.</p></td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/configure-ios/analog-digital-and-sfp-ios/opal-rt-board-workflow/analog-and-resolver-configuration.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.