> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/control-exciters/ieee-scrx.md).

# IEEE SCRX

## Description

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-fa7de9f3e38ac679e0be999e4dee5a48393ce20b%2Fimage%20(850).png?alt=media" alt="" width="175"><figcaption></figcaption></figure>

The **SCRX** block, located in the **Control Exciters** library, is based on the IEEE Std. 412.5 type SCRX excitation system model. It provides a general model of a static excitation system representing a silicon-controlled rectifier. The exciter may be bus fed or solid fed. The model was described in \[1] as part of a study on load rejection over-voltages. The SCRX component was developed in line with references \[1] and \[2].

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-15e9bfa4a66aa745a0f9e2bab3f2fc70711bb6fd%2Fimage%20(851).png?alt=media" alt=""><figcaption><p>SCRX diagram</p></figcaption></figure>

The Cswitch parameters determine whether the voltage signal is taken from the bus (generator terminal voltage) or from a solid source (a fixed 1.0 pu signal).

The negative current logic controls whether negative field current Ifd is allowed.

* If Rc\_Rfd = 0, negative Ifd is allowed and Efd = Ex in all cases.
* If Rc\_Rfd > 0, the logic depends on the sign of Ifd:
  * if Ifd is positive, Efd = Ex;
  * if Ifd is negative, Efd = − XadIfd\*Rc\_Rfd.
* When bidirectional Ifd is allowed, the exciter represents two rectifier bridges connected in reverse polarity. When unidirectional Ifd is enforced, the system represents a single bridge rectifier protected by a crowbar circuit with resistance Rc and a reverse bypassing thyristor \[1].

{% hint style="info" %}
The HYPERSIM<sup>®</sup> simulation option Set Initial Conditions must be checked for the automatic initialization to work properly.
{% endhint %}

## Mask parameters

{% tabs %}
{% tab title="Exciter" %}

<table><thead><tr><th width="199.5999755859375">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Ta_Tb</strong></td><td>Gain reduction ratio Ta/Tb.</td></tr><tr><td><strong>Tb</strong></td><td>Time constant (s).</td></tr><tr><td><strong>K</strong></td><td>Exciter gain.</td></tr><tr><td><strong>Te</strong></td><td>Time constant (s).</td></tr><tr><td><strong>Emax</strong></td><td>Maximum field voltage output (pu).</td></tr><tr><td><strong>Emin</strong></td><td>Minimum field voltage output (pu).</td></tr><tr><td><strong>Cswitch</strong></td><td>Voltage source switch: bus fed = 0; solid fed = 1.</td></tr><tr><td><strong>Rc_Rfd</strong></td><td>Ratio of crowbar resistance to field winding resistance Rc/Rfd.</td></tr></tbody></table>
{% endtab %}

{% tab title="Initial values" %}

| Parameter | Description                                |
| --------- | ------------------------------------------ |
| **Efd0**  | Exciter output voltage initial value (pu). |

{% hint style="info" %}
Efd0 can be set manually by entering a numeric value, or automatically from load flow by referencing the synchronous machine variable. For a machine named "SM1": use "=SM1.EfdInit" for thermal or hydraulic machines, and "=SM1.EFD\_Init" for pu standard or pu fundamental machines. The HYPERSIM simulation option "Set Initial Conditions" must be selected for automatic initialization.
{% endhint %}
{% endtab %}
{% endtabs %}

## Inputs

<table><thead><tr><th width="200.4000244140625">Input</th><th>Description</th></tr></thead><tbody><tr><td><strong>Voel</strong></td><td>Overexcitation limiter output (pu).</td></tr><tr><td><strong>Vc1</strong></td><td>Signal proportional to compensated terminal voltage. If a l<mark style="color:yellow;">oad compensator block is not used upstream from the exciter,</mark> Vc1 equals Vt (main alternator terminal voltage) (pu).</td></tr><tr><td><strong>Vuel</strong></td><td>Under-excitation limiter output (pu).</td></tr><tr><td><strong>Vref</strong></td><td>Voltage regulator reference voltage (pu).</td></tr><tr><td><strong>Vs</strong></td><td>Output voltage of a power system stabilizer (PSS) (pu).</td></tr><tr><td><strong>Ifd</strong></td><td>Synchronous machine field current (pu).</td></tr><tr><td><strong>Vd</strong></td><td>d-axis component of generator terminal voltage (pu).</td></tr><tr><td><strong>Vq</strong></td><td>q-axis component of generator terminal voltage (pu).</td></tr></tbody></table>

{% hint style="danger" %}
**Vuel** and **Voel** are normally inputs for this excitation system. You can choose fixed constant values directly in the mask by selecting the “internal” option.
{% endhint %}

The observable field current Ifd from the synchronous machine in HYPERSIM must be multiplied by Xad = Xd − Xl before being applied to the exciter.

## Outputs

<table><thead><tr><th width="201.20001220703125">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>Efd</strong></td><td>Exciter output voltage (pu).</td></tr></tbody></table>

The terminal voltage is computed from Vd and Vq : $$V\_t =\sqrt{ V\_{d^2} + V\_{q^2}}$$

## References

1. F.P. de Mello, L. M. Leuzinger and R. J. Mills, "Load rejection overvoltages as affected by excitation system control," in IEEE Transactions on Power Apparatus and Systems, vol. 94, no. 2, pp. 280-287, March 1975, doi: 10.1109/T-PAS.1975.31853.
2. PSS®E 34.2.0 Model Library. NY, USA: Siemens Industry, Inc., 2017.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/library-blocks-reference/control-exciters/ieee-scrx.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.