> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/control-governors/ieee-hygov.md).

# IEEE HYGOV

## Description

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-b4be1eefcaddbdc5fd8e75dee2fe02b2edae2659%2Fimage%20(772).png?alt=media" alt="" width="188"><figcaption></figcaption></figure>

The **IEEE HYGOV** block, located in the **Control Governors** library, is the hydro turbine-governor model implemented in line with references \[1-3].

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-751c08384ba58892c075fc413c0f5c7765e6f1f1%2Fimage%20(773).png?alt=media" alt=""><figcaption><p>HYGOV diagram</p></figcaption></figure>

{% hint style="info" %}
The HYPERSIM<sup>®</sup> simulation option Set Initial Conditions must be checked for the automatic initialization to work properly.
{% endhint %}

## Mask parameters

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-b4d3915f07caba9bd2c597b7e2d6b70a099736c5%2FHYGOV.jpg?alt=media" alt=""><figcaption></figcaption></figure>

{% tabs %}
{% tab title="HYGOV" %}

<table><thead><tr><th width="199.5999755859375">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>R</strong></td><td>Permanent droop (pu). Range: 0 &#x3C; R &#x3C; 0.1.</td></tr><tr><td><strong>r</strong></td><td>Temporary droop (pu). Range: 0 &#x3C; r &#x3C; 2.0.</td></tr><tr><td><strong>VELM</strong></td><td>Gate velocity limit (pu/s).</td></tr><tr><td><strong>GMAX</strong></td><td>Maximum gate opening limit (pu). Range: 0 &#x3C; GMAX ≤ 1.0.</td></tr><tr><td><strong>GMIN</strong></td><td>Minimum gate opening limit (pu). Range: 0 ≤ GMIN &#x3C; 1.0.</td></tr><tr><td><strong>TR</strong></td><td>Governor time constant (s). Range: 0.04 &#x3C; TR &#x3C; 30.</td></tr><tr><td><strong>TF</strong></td><td>Filter time constant (s). Range: 0.04 &#x3C; TF &#x3C; 0.1.</td></tr><tr><td><strong>TG</strong></td><td>Servo time constant (s). Range: 0.04 &#x3C; TG &#x3C; 1.0.</td></tr><tr><td><strong>TW</strong></td><td>Water time constant (s). Range: > 0.04.</td></tr><tr><td><strong>At</strong></td><td>Turbine gain (pu).</td></tr><tr><td><strong>Dturb</strong></td><td>Turbine damping (pu).</td></tr><tr><td><strong>qNL</strong></td><td>No-load flow (pu).</td></tr></tbody></table>
{% endtab %}

{% tab title="Initial values" %}

<table><thead><tr><th width="200.20001220703125">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Pm0</strong></td><td>Initial mechanical power output (pu).</td></tr><tr><td><strong>w0</strong></td><td>Speed reference (pu).</td></tr></tbody></table>

{% hint style="info" %}
The **speed reference w0** can be set manually by entering a numerical value, or automatically from load flow results by referencing a synchronous machine variable in the machine netlist.\
For example, if the synchronous machine name is “SM1”, set the speed reference as “=SM1.wo” if a thermal machine or a hydraulic machine is used, and as “=SM1.Wm\_Init” if a pu standard or pu fundamental machine is used.

Similarly, set the **initial mechanical power output Pm0** as “=SM1.Peo/SM1.BaseMVA” if a thermal machine or a hydraulic machine is used, and as “=SM1.lfP/1e6/SM1.sBase” if a pu standard or pu fundamental machine is used, where Peo and lfP are the initial power outputs of the machines, respectively.
{% endhint %}
{% endtab %}
{% endtabs %}

## Inputs

<table><thead><tr><th width="199.60003662109375">Input</th><th>Description</th></tr></thead><tbody><tr><td><strong>w</strong></td><td>Machine actual speed (pu).</td></tr><tr><td><strong>VAR</strong></td><td>External control reference (pu).</td></tr></tbody></table>

## Outputs

<table><thead><tr><th width="200.4000244140625">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>Gate_p</strong></td><td>Gate position (pu).</td></tr><tr><td><strong>Pm</strong></td><td>Mechanical power output (pu).</td></tr></tbody></table>

## References

\[1] P. Kundur, Power System Stability and Control, New York:McGraw-Hill, 1994.

\[2] PSS®E 34.2.0 Model Library. NY, USA: Siemens Industry, Inc., 2017.

\[3] T. Tshibungu and J. Mahseredjian, Exciters and Governors: Governor-Turbine HYGOV. EMTP-EMTPWorks, 2016.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/library-blocks-reference/control-governors/ieee-hygov.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.