> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-loads/arc-furnace.md).

# Arc Furnace

## Description

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-1bb91fee927d898dc6cd05161393daa4948e1410%2Fimage%20(1135).png?alt=media" alt="" width="73"><figcaption></figcaption></figure>

The **Arc furnace** block, located in the **Network Loads library**, represents both the static and dynamic behavior of arc resistance. The furnace characteristic depends on active power consumption, which varies with operating conditions. This model is used to study harmonics returned to the network and power quality, particularly voltage flicker.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-e7066d62dfd01995e96bbfd4c132681350e54402%2Fimage%20(1136).png?alt=media" alt="" width="557"><figcaption><p>Block diagram of the arc furnace implementation</p></figcaption></figure>

The V-I characteristic includes three regions and is computed from the arc furnace parameters and operating conditions. The R2 resistance (arc resistance at the ignition threshold) depends only on the extinction and ignition voltages and their respective currents. The pre‑ignition resistance also depends on these parameters and the average operating power. A sinusoidal or random variation can be added to the pre‑ignition resistance, allowing the model to represent periodic and stochastic changes before ignition.

<details>

<summary>Variables used in the block diagram</summary>

The following variable names are used:

* Vall (furnace ignition voltage),
* Vex (furnace extinction voltage),
* I2–I1 (difference between ignition and extinction currents),
* Pmoy (average operating power),
* Amp\_sin (amplitude of sinusoidal variation),
* Freq\_sin (frequency of sinusoidal variation),
* Pha\_sin (phase of sinusoidal variation),
* Amp\_al: (amplitude of random variation),
* Germe (random sequence seed for white noise),
* Type (arc resistance characteristic type),
* R1 (resistance of furnace static characteristic before ignition),
* R1' (final furnace resistance before ignition),
* and R2 (furnace resistance once ignited).

</details>

## Mask parameters

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-dc083b1f432740db67fd3f148485cc922ccf66f3%2Fimage%20(1137).png?alt=media" alt="" width="563"><figcaption></figcaption></figure>

<table><thead><tr><th width="258.67828369140625">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Description</strong></td><td>Free-form description of the component.</td></tr><tr><td><strong>Arc resistance variation characteristic</strong></td><td><p>Characteristic type of arc resistance; operating mode:</p><ul><li>Static: No variation of furnace resistance before ignition.</li><li>Static + sinusoidal: Modulates the furnace resistance before ignition with a low-frequency sine.</li><li>Static + white noise: Randomly varies the furnace resistance before ignition with low-frequency white noise.</li></ul></td></tr><tr><td><strong>Active power consumption - P</strong></td><td>Average power representing the operating conditions of the furnace; used to calculate the characteristic of the furnace before ignition, irrespective of the operating mode (MW).</td></tr><tr><td><strong>Ignition voltage - Vig</strong></td><td>Voltage required to ignite the furnace (strike the electric arc) (V peak LG).</td></tr><tr><td><strong>Extinction voltage - Vex</strong></td><td>Voltage at which the furnace extinguishes; must be lower than the ignition voltage (V peak LG).</td></tr><tr><td><strong>Current difference (Iig - Iex)</strong></td><td>Difference between ignition and extinction currents; must be greater than 0 (kA).</td></tr><tr><td><strong>Sinusoidal mode- Frequency</strong></td><td>Frequency of sinusoidal variation (Hz).</td></tr><tr><td><strong>Sinusoidal mode- Amplitude</strong></td><td>Amplitude of sinusoidal variation (Ω).</td></tr><tr><td><strong>Sinusoidal mode- Phase</strong></td><td>Phase of sinusoidal variation (deg).</td></tr><tr><td><strong>Noise mode - Amplitude</strong></td><td>Amplitude of random variation (Ω).</td></tr><tr><td><strong>Noise mode - Seed</strong></td><td>Random sequence seed for white noise.</td></tr></tbody></table>

## Conserving ports

<table><thead><tr><th width="220.39996337890625">Port</th><th>Description</th></tr></thead><tbody><tr><td><strong>net_1</strong></td><td>Network connection (supports only 3-phase connections)</td></tr></tbody></table>

## Inputs

This block has no inputs.

## Outputs

This block has no outputs.

## Signals available for monitoring and external I/O connections (via sensors form)

All block inputs and outputs are available as signals for monitoring and for external I/O connections.

Additional signals are also available and are listed below with their descriptions.

<table><thead><tr><th width="240.06976318359375">Signal</th><th>Description</th></tr></thead><tbody><tr><td><strong>I(a,b,c)</strong></td><td>Arc furnace current (A).</td></tr><tr><td><strong>V(a,b,c)</strong></td><td>Arc furnace voltage (V).</td></tr><tr><td><strong>WhiteNoise</strong></td><td>Random variation added to the arc furnace resistance when the selected characteristic is Static + white noise, before bandpass filtering (Ω).</td></tr><tr><td><strong>WhiteNoiseFilt</strong></td><td>Random variation added to the arc furnace resistance when the selected characteristic is Static + white noise, after bandpass filtering (Ω).</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-loads/arc-furnace.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.