> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-rlc/series-non-linear-l.md).

# Series Non-Linear L

## Description

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-e792d283c53a744bc4535f2a1389d0830448a5e1%2Fimage%20(295).png?alt=media" alt=""><figcaption></figcaption></figure>

The **Series Non-Linear L** block, located in the **Network RLC** library, represents a non linear inductor.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-6708aa63d52513256e319c95eebe447e739a4d41%2Fjfx9517765089718178351.png?alt=media" alt=""><figcaption><p>Hysteresis diagram</p></figcaption></figure>

{% hint style="info" %}
By default, this block operates in single-phase mode. When it is connected to a three-phase bus signal, it automatically switches to three-phase operation.
{% endhint %}

## Mask parameters

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-f522d9c343b05f7859c4c1f9b92ea19b8553a972%2F11.jpg?alt=media" alt=""><figcaption></figcaption></figure>

{% tabs %}
{% tab title="General" %}

<table><thead><tr><th width="206">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Nonlinear representation</strong></td><td>Select mode : Saturation or Saturation + Hysteresis</td></tr><tr><td><strong>Iteration</strong></td><td>Enable or disable iteration mode</td></tr><tr><td><strong>Base Power</strong></td><td>Total base power (MVA)</td></tr><tr><td><strong>Base Voltage</strong></td><td>Base voltage: use rms line-to-line (LL) if the inductance is connected to a 3‑phase bus, and rms line-to-neutral (LN) if only one phase is connected (kV)</td></tr><tr><td><strong>Base Frequency</strong></td><td>Base frequency (Hz)</td></tr><tr><td><strong>Initial flux</strong></td><td>(Wb)</td></tr></tbody></table>
{% endtab %}

{% tab title="Saturation" %}

<table><thead><tr><th width="237">Parameter</th><th>Hy</th></tr></thead><tbody><tr><td><strong>Number of data points</strong></td><td>Number of points that characterize the saturation curve t (from 1 to 32).</td></tr><tr><td><strong>Symmetry about the x-axis</strong></td><td>Symmetric: Define the curve from 0 to +Vmax; the curve is duplicated for the negative section.<br>Asymmetric: Define the curve from −Vmax to +Vmax; the negative part can differ from the positive part.</td></tr><tr><td><strong>Saturation Current</strong></td><td>Vector of current points; each point corresponds to a location on the curve (A).</td></tr><tr><td><strong>Saturation Flux</strong></td><td>Vector of flux points; each point corresponds to a location on the curve (Wb).</td></tr></tbody></table>
{% endtab %}

{% tab title="Hysteresis" %}

<table><thead><tr><th width="237">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Coercitive current - Ic</strong></td><td>(A)</td></tr><tr><td><strong>Saturation current - Is</strong></td><td>(A)</td></tr><tr><td><strong>Current tolerance</strong></td><td>(A)</td></tr><tr><td><strong>Slope at I=infinity</strong></td><td>(H</td></tr><tr><td><strong>Remanent flux - Φr</strong></td><td>(Wb)</td></tr><tr><td><strong>Saturation flux - Φs</strong></td><td>(Wb)</td></tr><tr><td><strong>Flux tolerance</strong></td><td>(Wb)</td></tr><tr><td><strong>Slope at Ic</strong></td><td>(H)</td></tr><tr><td><strong>Saturation mode</strong></td><td>Select mode Computational or Saturation curve</td></tr><tr><td><strong>Number of data points</strong></td><td>Select number of points from 2 to 10</td></tr><tr><td><strong>Saturation current</strong></td><td>for each point (A)</td></tr><tr><td><strong>Saturation flux</strong></td><td>for each point (Wb)</td></tr></tbody></table>
{% endtab %}
{% endtabs %}

## Conserving ports

<table><thead><tr><th width="219">Port</th><th>Description</th></tr></thead><tbody><tr><td><strong>Net_+</strong></td><td>Positive network connection</td></tr><tr><td><strong>Net_-</strong></td><td>Negative network connection</td></tr></tbody></table>

## Inputs

This block has no inputs.

## Outputs

This block has no outputs.

## Signals available for monitoring and external I/O connections (via sensors form)

All block inputs and outputs are available as signals for monitoring and for external I/O connections.

Additional signals are also available and are listed below with their descriptions.

<table><thead><tr><th width="242">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>FLUX</strong></td><td>(Vs)</td></tr><tr><td><strong>IMAG</strong></td><td>(A)</td></tr><tr><td><strong>SEG</strong></td><td></td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-rlc/series-non-linear-l.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.