> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-switches-and-breakers/gate-turn-off-thyristor-gto.md).

# Gate Turn-Off Thyristor (GTO)

## Description

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-06913caae2ffcd728efadd107cb3d59d6415f1ee%2Fimage%20(1087).png?alt=media" alt="" width="108"><figcaption></figcaption></figure>

The **GTO** block, located in the **Network Switches and Breakers** library, models a gate turn-off (GTO) thyristor that is switched on or off by a gate signal. The model accounts for forward voltage drop, forward and reverse breakover voltages, blocking current, snubber elements, holding current, and on/off resistances. An optional precision feature compensates for discretization errors at switching instants as a function of the simulation time step. The GTO turns on when the anode–cathode voltage exceeds the forward threshold and a positive pulse is present at the gate input (g > 0). When the gate signal is 0, the device starts to block, and the current does not stop instantaneously. An optional Fail reset mode raises a signal if the device reaches forward or reverse breakdown voltage or if an untimely firing occurs.

## Mask parameters

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-f4451dc92affdb5e44e787a9f9cef80acbafa895%2FGTO.jpg?alt=media" alt="" width="563"><figcaption></figcaption></figure>

### General

{% tabs %}
{% tab title="General" %}

<table><thead><tr><th width="201">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Vmin</strong></td><td>Forward voltage drop (V) [0, 1e12].</td></tr><tr><td><strong>Ropen</strong></td><td>Open-state resistance (ohm) [0, 1e12].</td></tr><tr><td><strong>Rclose</strong></td><td>Closed-state resistance (ohm) [0, 1e12].</td></tr><tr><td><strong>Rsnubber</strong></td><td>Snubber resistance (ohm) [0, 1e12].</td></tr><tr><td><strong>Csnubber</strong></td><td>Snubber capacitance (F) [0, 1e12].</td></tr><tr><td><strong>Control type</strong></td><td><ul><li><em>External input pins:</em> Accepts an integer control signal that is converted to a binary string in which each bit corresponds to a phase.</li><li><em>External input sensors:</em> Uses simulator digital inputs.</li></ul></td></tr></tbody></table>
{% endtab %}

{% tab title="Advanced" %}

| Parameter           | Description                                                                                                                                                                                         |
| ------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **Fail reset**      | Enables or disables fail reset mode. Valid values: {Enable, Disable}.                                                                                                                               |
| **Precision valve** | Enable: Recalculates the state-switch command using the exact time between steps (as a percentage of the time step). Disable: Does not apply precision correction. Valid values: {Enable, Disable}. |
| **Imin (A)**        | Holding current. Valid range: \[0, 1e12].                                                                                                                                                           |
| **Fbov (V)**        | Forward breakover voltage. Valid range: \[0, 1e12].                                                                                                                                                 |
| **Rbov (V)**        | Reverse breakover voltage. Valid range: \[0, 1e12].                                                                                                                                                 |
| {% endtab %}        |                                                                                                                                                                                                     |
| {% endtabs %}       |                                                                                                                                                                                                     |

## Conserving ports

<table><thead><tr><th width="199.5999755859375">Port</th><th>Description</th></tr></thead><tbody><tr><td><strong>Net_1</strong></td><td>Network connection.</td></tr><tr><td><strong>Net_2</strong></td><td>Network connection.</td></tr></tbody></table>

## Inputs

<table><thead><tr><th width="199.5999755859375">Input</th><th>Description</th></tr></thead><tbody><tr><td><strong>D</strong></td><td>Delay used for the precision valve.</td></tr><tr><td><strong>P</strong></td><td>Binary-coded firing pulses.</td></tr></tbody></table>

## Outputs

This block has no outputs.

## Signals available for monitoring and external I/O connections (via sensors form)

All block inputs and outputs are available as signals for monitoring and for external I/O connections.

Additional signals are also available and are listed below with their descriptions.

<table><thead><tr><th width="201.20001220703125">Signal</th><th>Description</th></tr></thead><tbody><tr><td><strong>FailSig</strong></td><td>Fail reset signal.</td></tr><tr><td><strong>I</strong></td><td>Diode current (A).</td></tr><tr><td><strong>Delay</strong></td><td>Delay due to forward voltage drop (s).</td></tr><tr><td><strong>Delay12</strong></td><td>Delay in forward GTO thyristor mode (s).</td></tr><tr><td><strong>State12</strong></td><td>Diode state.</td></tr><tr><td><strong>DelayExt12</strong></td><td>Delay for external trigger (s).</td></tr><tr><td><strong>Cmd12</strong></td><td>Signal state command.</td></tr><tr><td><strong>CmdExt12</strong></td><td>Signal state external command.</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-switches-and-breakers/gate-turn-off-thyristor-gto.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.