> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/model-and-simulation/import-models-from-external-software-or-code/import-from-emtp/partialy-compatible-components.md).

# Partialy Compatible Components

## Control <a href="#control" id="control"></a>

| Component in EMTP | Block in HYPERSIM       | Incompatibility                                          |
| ----------------- | ----------------------- | -------------------------------------------------------- |
| delay             | delay                   | Arbitrary pulse delay mode not supported                 |
| derivative        | derivative              | End-step du/dt, and Mid-step d2u/dt2 modes not supported |
| table function    | Floating-point constant | The maximum number of rows supported is 500              |

## Lines <a href="#lines" id="lines"></a>

| Component in EMTP     | Block in HYPERSIM    | Incompatibility                                        |
| --------------------- | -------------------- | ------------------------------------------------------ |
| CP line/cable m-phase | Constant param, m-ph | HS models only support 1, 2, 3, 4, 6, 9, and 12 phases |

## Loads <a href="#loads" id="loads"></a>

| Component in EMTP      | Block in HYPERSIM      | Incompatibility                                                                               |
| ---------------------- | ---------------------- | --------------------------------------------------------------------------------------------- |
| PQ load with load-flow | PQ load with load-flow | Negative Power value not supported. Power will be set to 0. Visible ground pin not supported. |

## Machines <a href="#machines" id="machines"></a>

<table><thead><tr><th width="145.25">Component in EMTP</th><th width="139.75">Block in HYPERSIM</th><th>Incompatibility</th></tr></thead><tbody><tr><td>Asynchronous</td><td>Induction motor with cage rotor</td><td><p>Steady-state initialization and total saturation are not supported.</p><p>Saturation data in D-axis is limited to 10 points.</p><p>Saturation data in Q-axis is not considered in HYPERSIM.</p><p>Deep bar factor not supported.</p><p>Lock rotor shaft for negative speed is not supported.</p><p>Absolute speed damping is not supported.</p><p>HYPERSIM supports only WYE grounded connection for the armature winding.</p><p>Rotor speed control is not supported.</p><p>The Multi-masses model is not supported.</p><p>Mechanical torque in pu control is not supported.</p></td></tr><tr><td>Synchronous</td><td>Synchronous machine</td><td><p>HYPERSIM uses EL 1.0 and EU 1.2 for saturation in D-axis.</p><p>Sgu is smaller than Sgl. Values swapped.</p><p>Saturation data in Q-axis is not considered in HYPERSIM.</p><p>HYPERSIM does not support Canay impedance in extra data.</p><p>HYPERSIM only represents 1 damper in the D axis.</p><p>HYPERSIM only supports 2 dampers in the Q axis.</p><p>HYPERSIM support only WYE grounded connection for the armature winding.</p><p>HYPERSIM supports only open circuit data (D Axis).</p><p>HYPERSIM supports only open circuit data (Q Axis).</p><p>The Multi-masses model is not supported.</p></td></tr></tbody></table>

## Meters <a href="#meters" id="meters"></a>

| Component in EMTP         | Block in HYPERSIM    | Incompatibility                                       |
| ------------------------- | -------------------- | ----------------------------------------------------- |
| Control signal meter      | Control signal meter | RMS meter not supported                               |
| Current scope and observe | I measurement, 1ph   | v and p observables not supported                     |
| Simulation probe          | Simulation probe     | Simulation stop time and Base Frequency not supported |

## Nonlinear <a href="#nonlinear" id="nonlinear"></a>

| Component in EMTP | Block in HYPERSIM  | Incompatibility                                                                                                                                                  |
| ----------------- | ------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| L nonlinear       | Series nonlinear L | Negative values are not supported                                                                                                                                |
| ZnO               | Series nonlinear R | <p>HYPERSIM supports a maximum of 10 exponential segments.</p><p>v, p, e observables not supported.</p><p>Exponential segments after flashover not supported</p> |

## RLC branches <a href="#rlc-branches" id="rlc-branches"></a>

| Component in EMTP | Block in HYPERSIM | Incompatibility                 |
| ----------------- | ----------------- | ------------------------------- |
| PI                | PI                | Single-phase line not supported |
| PI small          | PI small          | Single-phase line not supported |

## Sources <a href="#sources" id="sources"></a>

| Component in EMTP               | Block in HYPERSIM               | Incompatibility                                                                                                                                                                                                                                 |
| ------------------------------- | ------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| AC current source               | AC current source               | Unsupported start and stop time                                                                                                                                                                                                                 |
| AC voltage source               | AC voltage source               | <p>Serial voltage source not supported.</p><p>Unsupported start and stop time</p>                                                                                                                                                               |
| AC voltage source (3-ph)        | AC V source                     | Unsupported start and stop time                                                                                                                                                                                                                 |
| AC voltage source and impedance | AC voltage source and impedance | <p>Unsupported connections to pink</p><p>Visible ground pin not supported</p><p>Unsupported start and stop time</p>                                                                                                                             |
| Controlled current source       | Controlled I source, 1-ph       | Unsupported start and stop time                                                                                                                                                                                                                 |
| Controlled voltage source       | Controlled V source, 1-ph       | Unsupported start and stop time                                                                                                                                                                                                                 |
| Load-Flow Bus                   | Load-Flow equivalent            | <p>HYPERSIM only supports Positive Sequence R impedance</p><p>HYPERSIM only supports Positive Sequence L impedance</p><p>Remote control bus not supported</p><p>R must be entered as Sequence Data</p><p>L must be entered as Sequence Data</p> |

## Switches <a href="#switches" id="switches"></a>

| Component in EMTP             | Block in HYPERSIM     | Incompatibility                                                           |
| ----------------------------- | --------------------- | ------------------------------------------------------------------------- |
| Controlled switch             | Controlled switch     | v and p observables not supported                                         |
| Diode (ideal)                 | Diode                 | Closed at T0 not supported                                                |
| Ideal switch                  | Circuit breaker, 1-ph | v and p observables not supported                                         |
| Ideal switch : Breaker Symbol | Circuit breaker, 1-ph | v and p observables not supported                                         |
| Thyristor (ideal)             | Thyristor (ideal)     | <p>v and p observables not supported</p><p>Closed at T0 not supported</p> |

## Transformers <a href="#transformers" id="transformers"></a>

<table><thead><tr><th width="162.75">Component in EMTP</th><th width="137">Block in HYPERSIM</th><th>Incompatibility</th></tr></thead><tbody><tr><td>ideal unit m-windings</td><td>ideal unit m-windings</td><td><p>HYPERSIM only support one secondary winding with a controlled ratio</p><p>HYPERSIM only supports a maximum of two secondary windings</p></td></tr><tr><td>Three-phase nameplate input</td><td>2 winding</td><td><p>HYPERSIM doesn't support</p><p>R1 &#x3C;= 0, using R1 = 1E-6</p><p>L1 &#x3C; 1E-6 pu, using L1 = 1E-6 pu</p><p>R2 &#x3C;= 0, using R2 = 1E-6</p><p>L2 &#x3C; 1E-6 pu, using L2 = 1E-6 pu</p><p>Using Rm and Lm = 30000 pu for linear transformer</p><p>Primary and secondary neutral impedance values must be entered manually.</p><p>Exported mask not supported</p></td></tr><tr><td>YgYgD nameplate input O</td><td>3 winding, w/sat</td><td><p>HYPERSIM doesn't support</p><p>R1 &#x3C;= 0, using R1 = 1E-6</p><p>L1 &#x3C; 1E-6 pu, using L1 = 1E-6 pu</p><p>R2 &#x3C;= 0, using R2 = 1E-6</p><p>L2 &#x3C; 1E-6 pu, using L2 = 1E-6 pu</p><p>R3 &#x3C;= 0, using R3 = 1E-6</p><p>L3 &#x3C; 1E-6 pu, using L3 = 1E-6 pu</p><p>Using Rm and Lm = 30000 pu for linear transformer</p><p>Exported mask not supported</p></td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/model-and-simulation/import-models-from-external-software-or-code/import-from-emtp/partialy-compatible-components.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.