> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/hypersim/model-and-simulation/optimize-the-model/select-the-right-line-or-cable.md).

# Select the Right Line or Cable

## Overview

HYPERSIM provides several transmission line and cable models with different levels of accuracy, computational requirements, and capabilities. Selecting the appropriate model depends on the type of study, line or cable characteristics, simulation time step, and frequency range of interest.

This page describes the available line models and provides guidelines for selecting the appropriate model for steady-state, transient, and frequency-dependent studies.

## Line models <a href="#line-models" id="line-models"></a>

Transmission lines are characterized by two fundamental electrical parameters: the **series impedance** (**Z**), which represents longitudinal electromagnetic effects, and the **shunt admittance** (**Y**), which represents transverse electromagnetic effects.

Based on how these parameters are represented, time-domain transmission line models can be broadly classified into two categories: **lumped-parameter models** and **distributed-parameter models**.

In lumped-parameter models, the **Z** and **Y** parameters are evaluated at a single frequency and assumed to be concentrated at discrete locations. These models are generally well suited for steady-state studies, where only one frequency is of interest.

For transient studies, **distributed-parameter models** are typically more appropriate because they represent the line parameters continuously along its length, allowing wave propagation effects to be accurately captured. Depending on the model, the **Z** and **Y** parameters may be treated as either **constant** or **frequency-dependent**.

The following figure presents a general classification of the transmission line models available in HYPERSIM.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-d2d8b3ebb36b4ae682801e900255b0deef91e86b%2Flines-models.png?alt=media" alt=""><figcaption></figcaption></figure>

<details>

<summary><strong>RL coupled</strong></summary>

For very short distribution lines, the line capacitance is often negligible and can be ignored. These lines are therefore typically modeled using only the conductors' **series resistance and inductance**, represented as **coupled RL branches**.

**Advantages**

* Simple and computationally efficient model.
* Suitable for short-line studies where capacitive effects are insignificant.

**Limitations**

* Does not represent line capacitance or propagation effects.
* Cannot be used as a decoupled network element.
* Recommended only for very short lines in distribution systems where capacitive effects can be neglected.

</details>

<details>

<summary><strong>PI model</strong></summary>

The **PI line model** represents a transmission line using a lumped **RLC equivalent circuit**. Its parameters are calculated at a single frequency, typically the power-system fundamental frequency, making the model exact only at that frequency. Although multiple PI sections can be connected in series to approximate traveling-wave behavior, the resulting representation remains an approximation and does not accurately capture wave propagation phenomena. Consequently, the PI line model is primarily intended for **steady-state and low-frequency studies**.

**Advantages**

* Simple and computationally efficient model.
* Well suited for steady-state and power-frequency analyses.

**Limitations**

* Does not accurately represent traveling-wave and electromagnetic transient phenomena.
* Accuracy decreases as the frequency departs from the frequency at which the parameters were calculated.
* Cannot be used as a decoupled network element.

</details>

<details>

<summary><strong>Constant parameter (CP) model</strong></summary>

The **Constant Parameter (CP) line model**, also known as the **Bergeron model** \[1], is based on the traveling-wave method for representing transmission lines. It consists of an ideal traveling-wave propagation function combined with resistive losses. Because the model uses parameters calculated at a single frequency, it provides an efficient representation of wave propagation while maintaining a relatively low computational cost.

The CP model is well suited for transient studies where frequency-dependent effects are limited. However, its accuracy decreases at higher frequencies because the propagation modes and surge impedance are assumed to be constant. As a result, frequency-dependent attenuation and dispersion effects are not accurately represented.

**Advantages**

* Accurately reproduces traveling-wave effects associated with transients, such as faults and switching events.
* Computationally efficient.
* Can be used as a decoupling element in parallel simulations.

**Limitations**

* The surge impedance and propagation function are valid only at the frequency used to derive the line parameters.
* Frequency-dependent effects are not represented.
* High-frequency attenuation (damping) is typically neglected, which may reduce accuracy for fast electromagnetic transients.

</details>

<details>

<summary><strong>Frequency-dependent (FD) line model (Modal-type)</strong></summary>

The **Frequency-Dependent (FD) line model** is based on **modal decomposition techniques** \[2]. It extends the Constant Parameter (CP) model by accurately fitting the **surge impedance** and **propagation functions** of each propagation mode over a range of frequencies. As a result, the FD model provides a more accurate representation of frequency-dependent line behavior for many transmission-line applications.

However, the model assumes a **constant modal transformation matrix**, evaluated at a single frequency. This assumption is generally valid for **balanced or nearly balanced overhead lines**, but becomes increasingly inaccurate for unbalanced configurations where the modal transformation varies with frequency. Consequently, the FD model is best suited for overhead lines with symmetric or near-symmetric geometries.

Power cables are inherently unbalanced because the capacitances between conductors and ground are not symmetrical. Therefore, the modal-domain FD approach should not be used for cable modeling. For cable applications requiring frequency-dependent effects, HYPERSIM provides the **Wideband line model**, which is formulated directly in the **phase domain**.

**Advantages**

* Accurate representation of frequency-dependent effects for balanced and near-balanced overhead lines.
* More accurate than the CP model over a wide frequency range.
* Relatively fast computational performance.
* Can be used as a decoupling element in parallel simulations.

**Limitations**

* Applicable only to balanced or nearly balanced overhead-line configurations.
* Accuracy decreases for significantly unbalanced lines.
* Not suitable for cable modeling. For cables, the **Wideband** model should be used instead.

</details>

<details>

<summary><strong>Wideband (WB) line/cable model (Phase-type)</strong></summary>

The **Wideband line/cable model**, also known as the **Universal Line Model (ULM)** \[3], provides the most accurate representation of transmission lines and cables available in HYPERSIM. Unlike modal-domain approaches, the ULM computes the **surge impedance** and **propagation functions** directly in the **phase domain**, enabling accurate modeling of frequency-dependent effects in both balanced and unbalanced systems.

Because it operates in the phase domain, the ULM accurately captures coupling effects between conductors and parallel lines, making it particularly well suited for electromagnetic transient studies involving cables and complex line configurations. As a result, it is generally the recommended model when the highest level of accuracy is required.

**Advantages**

* Most accurate transmission line and cable model available in HYPERSIM.
* Accurately represents frequency-dependent effects over a wide frequency range.
* Well suited for both overhead lines and cables, including unbalanced configurations.
* Provides an accurate representation of coupling effects between parallel lines.
* Can be used as a decoupling element in parallel simulations.

**Limitations**

* Higher computational requirements than other line models due to its increased complexity.
* Requires the surge impedance and propagation functions to be approximated by rational functions using an external fitting process.

</details>

### Basic modeling guidelines <a href="#basic-modeling-guidelines" id="basic-modeling-guidelines"></a>

The following table summarizes the available line models and their key characteristics.

| Line model     | Accuracy  | Computational burden | Recommended applications                                                                     |
| -------------- | --------- | -------------------- | -------------------------------------------------------------------------------------------- |
| **RL coupled** | Low       | Low-medium           | General 50 Hz – 60 Hz steady state studies for very short lines in distribution systems      |
| **PI**         | Medium    | Low-medium           | General 50 Hz – 60 Hz, steady state studies                                                  |
| **CP**         | Good      | Low                  | Transient simulations, fault studies                                                         |
| **FD**         | Very good | Medium               | High‐accuracy transients simulation involving overhead lines, balanced and nearly unbalanced |
| **WB**         | Excellent | High                 | High‐accuracy transient simulations especially with cables and unbalanced lines              |

For **distributed-parameter (traveling-wave) line models**, the simulation time step must be selected based on the fastest response that needs to be represented. In particular, the **line propagation delay** must be greater than the simulation time step to ensure accurate modeling of traveling-wave phenomena.

The **travel time**, or **propagation delay** (*τ*), of a transmission line is defined as:

$$
\tau=\frac{l}{v}
$$

where $$l$$ is the length of the line and $$v$$ is the propagation velocity defined as:

$$
v=\frac{1}{\sqrt{L'C'}}
$$

where $$L'$$ and $$C'$$ are respectively the inductance and capacitance of the line per unit length.

The **propagation delay** can be compared with the simulation time step (*Δt*) to determine whether a **lumped-parameter model** (such as the PI model) or a **traveling-wave model** (such as the CP model) is more appropriate for the study.

The following figure presents a decision tree for selecting a transmission line model based on the line propagation delay. For studies involving significant high-frequency phenomena, **FD line models** may be preferred over **CP models** because they provide a more accurate representation of frequency-dependent effects. However, FD models require more computational resources and are therefore generally recommended for reduced-size networks or studies where higher accuracy is essential.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-c1e7e132d5a4bd7aa7741e79ec7e1aa3631e3968%2Flines-models-selection.png?alt=media" alt=""><figcaption></figcaption></figure>

Overhead transmission lines are often classified according to their length. Based on typical values of resistance (**R**), inductance (**L**), and capacitance (**C**) per unit length (see *Typical Electrical Parameters*), the following classification is commonly used \[4]:

* **Short lines**: Lines shorter than approximately **80 km**. Their shunt capacitance is generally negligible and they can often be represented by their series impedance only, using an **RL coupled model**.
* **Medium-length lines**: Lines between approximately **80 km and 200 km**. For these lines, capacitive effects become significant and are typically represented using **PI** or **CP** models.
* **Long lines**: Lines longer than approximately **200 km**. For such lines, distributed-parameter effects and wave propagation phenomena become important and should be represented using **traveling-wave models**, such as the **CP model**.

For **very short distribution lines**, the line capacitance is usually negligible. In these cases, the line can be modeled using only the conductor series resistance and inductance, represented as **coupled RL branches**.

### **PI versus CP line models** <a href="#pi-versus-cp-line-models" id="pi-versus-cp-line-models"></a>

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-64773b99ddb5e09e43bb24ef07c4107ad5d77433%2FPI-CP%3Dguidelines.png?alt=media" alt="" width="463"><figcaption></figcaption></figure>

The following circuit illustrates a simple network used to compare the behavior of **PI** and **CP** transmission line models. As shown in the figure below, the **CP model** (red trace) clearly captures the traveling-wave fronts that occur during line energization. Because it is based on distributed parameters, the CP model accurately represents wave propagation along the line.

In contrast, the **PI model** (blue trace) is a lumped-parameter representation and therefore cannot accurately reproduce the distributed nature of the line or the associated traveling-wave effects. Using **two PI sections in cascade** (green trace) provides a better approximation of wave propagation, but the accuracy remains limited.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-0b7e388e55d62389766ade585e9bbaee6fc33ca8%2FPI-CP-guidelines-results.png?alt=media" alt=""><figcaption></figcaption></figure>

It should be noted that an increasingly large number of cascaded PI sections would be required to approach the behavior of a true distributed-parameter model. In theory, an infinite number of PI sections would be needed to represent traveling-wave phenomena exactly.

Users can enter the parameters of **PI** and **CP** line models manually (for example, **PI Section, 3-ph** and **Constant Param, 3-ph**) by specifying the transmission line **positive- and zero-sequence R, L, and C parameters**. Typical values are provided in [**Typical Electrical Parameters**](https://github.com/Opal-RT-Technologies/product-docs-hypersim/tree/release-2026.4/model-and-simulation/use-parameter-generators/line-parameters/typical-electrical-parameters.md).

For **CP line models**, the electrical parameters can also be calculated automatically from the line geometry using the **Line Data** block. The module generates a **.pun** file containing the computed line parameters, which can then be imported into the CP component parameter dialog.

### Frequency-dependent FD lines <a href="#frequency-dependent-effect" id="frequency-dependent-effect"></a>

#### Frequency-dependent effect <a href="#frequency-dependent-effect" id="frequency-dependent-effect"></a>

**Frequency-dependent (FD) line models** account for both **conductor skin effect** and **frequency-dependent ground-return effects**.

* **CP line model**: The surge impedance and propagation function are calculated at a single frequency. As a result, frequency-dependent attenuation is not represented, and high-frequency components are not damped accurately.
* **FD line model**: The surge impedance and propagation functions are computed in the **modal domain**, allowing frequency-dependent effects to be represented over a wide frequency range.
* **Wideband (WB) model**: The surge impedance and propagation functions are computed directly in the **phase domain**, providing an accurate representation of frequency-dependent behavior for both balanced and unbalanced line configurations.

The following figure illustrates the typical differences between **frequency-dependent** and **non-frequency-dependent** line models in terms of **surge impedance** (*Z*<sub>*c*</sub>) and **propagation function** (*H*).

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-02286513f70f6741ff2fb9ec479ad4feca9094d5%2Ffrequency-dependent-effect.png?alt=media" alt=""><figcaption></figcaption></figure>

#### FD line fitter <a href="#fd-line-fitter" id="fd-line-fitter"></a>

The electrical parameters required by the **FD line model** can be calculated using the **Line Data** block. This block includes an internal fitting process that derives frequency-dependent **rational functions in the modal domain** and generates a **.pun** file containing all the parameters needed by the FD model in HYPERSIM.

To configure the FD line, load the generated **.pun** file into the component parameter dialog. An example of this workflow is provided in [**Frequency Dependent, 3-ph**](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-lines-and-cables/frequency-dependent-3-ph.md).

### Wideband line/cable fitter <a href="#wideband-line-cable-fitter" id="wideband-line-cable-fitter"></a>

To use **Wideband (WB) line models** in a simulation, the line or cable frequency-dependent parameters (RLCG matrices) must first be converted into **rational functions in the Laplace domain** using a fitting tool. These rational-function approximations are then discretized by the circuit solver to compute the line response in the time domain.

HYPERSIM provides the **Wideband Line/Cable Fitter** for this purpose. The fitter generates the **.dat** files required by the **Wideband Line/Cable** device. It accepts input data files generated by the [**Line Data**](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-lines-and-cables/line-data.md) (*.lyz) and* [**Cable Data**](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-lines-and-cables/cable-data.md) *(*.cyz) modules, and produces the fitted model used for wideband simulations.

<figure><img src="https://3623212549-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FLxgTpoh7kyPmQ5vuyqD7%2Fuploads%2Fgit-blob-42f6589e2a09a8ff766c88c245ccc4067101909e%2Fwideband-models-guidelines.png?alt=media" alt="" width="473"><figcaption></figcaption></figure>

For more information, see [**Wideband Line/Cable Fitter**](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-lines-and-cables/wideband-line-cable-fitter.md) and [**Wideband Line/Cable**](https://www.opal-rt.com/docs/hypersim/library-blocks-reference/network-lines-and-cables/wideband-line-cable.md).

## CIGRE guidelines <a href="#cigre-guidelines" id="cigre-guidelines"></a>

Power-system transient studies cover a wide frequency range, from **DC to several tens of megahertz**. Frequencies above the power frequency are typically associated with **electromagnetic transients**, while lower frequencies are mainly associated with **electromechanical transients** in rotating machines \[5].

Based on CIGRE guidelines, the following table relates the available transmission line models to the frequency range of interest and the representation of line parameters.

| Topic                                  | Low Frequency Transients (0.1 Hz–3 kHz) | Slow Front Transients (50/60 Hz–20 kHz)                                                               | Fast Front Transients (10 kHz–3 MHz)                         | Very Fast Front Transients (100 kHz–50 MHz) |
| -------------------------------------- | --------------------------------------- | ----------------------------------------------------------------------------------------------------- | ------------------------------------------------------------ | ------------------------------------------- |
| **Representation of transposed lines** | Lumped parameters, PI models            | Distributed parameter, multiphase model, PI model possible for 50/60 Hz                               | Distributed parameter, multiphase model                      | Distributed parameter, single-phase model   |
| **Line asymmetry**                     | Important                               | Capacitive and inductive asymmetry important, for statistical study inductive asymmetry not important | Negligible for single-phase simulations, otherwise important | Negligible                                  |
| **Frequency-dependent parameters**     | Important                               | Important                                                                                             | Important                                                    | Important                                   |

For all but very short transmission lines, **distributed-parameter models** are generally preferred. When frequency-dependent effects are significant, a **frequency-dependent line model** should be used. In such cases, accurate calculation of the line parameters requires detailed transmission line geometry and conductor data. For more information, see [Line Parameters](https://github.com/Opal-RT-Technologies/product-docs-hypersim/tree/release-2026.4/model-and-simulation/use-parameter-generators/line-parameters/README.md).

For **fast-front transients**, such as lightning surges, a **single-phase distributed-parameter model** is recommended \[6]. Each phase, including ground wires, is represented individually. Lightning studies typically require a more detailed representation of the line, including towers, tower-footing impedances, and related components, although modeling a limited number of spans is usually sufficient. The frequency dependence of the ground-return propagation mode is also an important consideration \[5].

## References <a href="#references" id="references"></a>

1. H. W. Dommel, “Digital computer solution of electromagnetic transients in single and multiphase networks,” IEEE Trans. Power App. Syst., vol. pas-88, pp. 388-99, 04/ 1969.
2. J. R. Marti, "Accurate modelling of frequency-dependent transmission lines in electromagnetic transient simulations," IEEE Trans. Power App. Syst., vol. PAS-101, pp. 147-55, 01/1982.
3. Morched A., Gustavsen B. and Tartibi M.: “A universal model for accurate calculation of electromagnetic transients on overhead lines and underground cables”. Power Delivery, IEEE Transactions, Volume: 14, Issue: 3, July 1999, pp. 1032 -1038
4. Kundur, P., Neal J. Balu, and Mark G. Lauby. Power System Stability and Control. New York: McGraw-Hill, 1994.
5. Das, J.C.. Transients in Electrical Systems: Analysis, Recognition, and Mitigation. US: McGraw-Hill Professional, 2010.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/model-and-simulation/optimize-the-model/select-the-right-line-or-cable.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.