# Release Notes 2020

## Version: 2020.3

### New features

* Added user guide to help EMTP users go to real-time with HYPERSIM
* Added Sequence Manager tool to record and manage test sequences from manual manipulations
* Added support for wound rotor in recently added Asynchronous Machine \[The former induction machine models will be kept as Legacy]
* Added support for MATLAB R2020a and R2020b
* Added exciter library models:
  * IEEET2
  * IEEET3
  * IEEEVC
  * EXDC2
  * EXST1
  * EXST3
  * EXPIC1
  * SCRX
* Added governor library model:
  * WEHGOV
* Added stabilizer library model:
  * PSS2A
* Added example models :
  * Emergency Diesel-Generator, Asynchronous Motor and 25 Synchronism-Check
  * Directional Overcurrent Protection
  * Type 4 Wind Farm model
  * EMTP Compatibility Introduction
  * EMTP IEEE 39Bus Benchmark
* Added a Data Name filter in the Sensor configuration view to help accelerate I/O assignment
* Added options to rename and delete I/O Interfaces
* Added Sigcmp to Advanced Function Editor in ScopeView, allowing comparison of a test signal to a reference signal with a user-defined tolerance
* Added Time format option in the data logger file browsing with ScopeView, allowing easily shifting results to time = 0 in graphs
* Added support for EXAC3, IEEET1, HYGOV, SCRX, AC8B, PSS2A and WEHGOV in PSS®E import
* Added progress bar when importing PSS®E files
* Added progress bar on Apply/Ok of I/O interface modifications to better follow updates of large I/O configurations
* Added Python API function to rename devices

### Improvements

* Improved Python API command setComponentParameter, making it synchronous, thus removing the need to add wait time after its call
* Improved PSSE import to skip buses with IDE=4 and all components connected to them
* Improved PSSE import to manage multiple sources (machines or voltage sources) on the same bus; the biggest source (the one with highest PT value in PSS®E) stays as is, whereas the smaller ones are connected through an intermediary resistor and their type is changed to PQ
* **Modbus Slave**: Improved automatic setting of ID for TCP slaves

### Bug fixes

* Fixed inconsistencies in tooltips of Network component forms
* Fixed unit of winding voltages for Saturable 2-winding transformer with tap changer that wasn't set to rmsLL like other transformers in the previous version
* Fixed issue where HYPERSIM would not start properly on a completely new Windows installation because of missing Microsoft libraries
* Fixed various issues with In1, Vt and Vc1 pins and the lower limit of exciter ST1A
* Fixed issue in AC3A exciter form where diagram would show Voel
* Fixed voltage source base voltage display value
* Fixed issue where sensor changes could be detected even if no changes were executed
* Fixed issue during uninstallation where some documentation files would remain
* Fixed occasional crash of a model engine when opening the Netlist after a specific sequence of actions
* **C37.118 Slave**: Fixed issue when sensors of a given slave are dispatched on different cores
* **C37.118 Slave**: Fixed missing editable slave name in I/O Interface configuration
* **DNP3**: Fixed possible crash of asynchronous process with certain configurations
* **IEC 61850**: Fixed UI crash when .icd file parsing failed
* **Modbus Slave**: Fixed issue with initial values and float data types
* **OPAL-RT Board**: Fixed issue where the FPGA bitstream could be reprogrammed twice upon starting the simulation
* **OPC UA Server**: Fixed Advanced Options which where showing at the root of the I/O Interface instance rather than in other elements of the tree

### Breaking changes

* Removed automatic generation of the EXata CPS files when opening I/O Interface

### Known issues

N/A

***

## Version: 2020.2

### New features

* Added export/import project option in the ribbon to facilitate sharing projects with other users
* Added example models:
  * Distribution and Industrial Power Systems | GHOST Microgrid Model
  * Distribution and Industrial Power Systems | Permanent Magnet Synchronous Machine-based Variable Frequency Drive (VFD)
  * FACTS & HVDC | Thyristor Controlled Series Capacitor (TCSC)
  * How To (Components) - Filter
  * How To (Components) - Fourier
  * How To (Components) - Mean
  * How To (Components) - Power
  * How To (Components) - Sequence\_Analyzer
* Added exciter library models:
  * DC2A
  * DC3A
  * ST2A
  * EXAC1
  * EXAC2
  * EXAC3
  * IEEET1
* Added governor library model HYGOV
* Added option to copy/paste content of error message windows
* Added relative file path capability in wideband line and COMTRADE playback components
* Added filter to list components per task in the netlist
* Added help button in load flow panel
* **OPAL-RT Boards**: Added support for MMC UI-based configuration in central systems
* **OPC UA Server**: Added support for configuration via GUI

### Improvements

* Improved user data input in network components by standardizing units of voltage and current
* Improved user feedback when diagnostic fails during software installation
* Improved HYPERSIM exiting time
* Improved diagnostic to gather more logs
* Improved tripping response time of protection model 81 - Frequency
* Improved Renewable Energy example models with new PV library model
* Improved duration of long tooltips to remain as long as the mouse-over
* **IEC 61850**: Improved driver to send data types as defined in the .icd file for SV NLE
* **Synchronization**: Improved network interface selection using a text field instead of pre-defined list

### Bug fixes

* Fixed close connection with signal group when the last SignalGroup instance is closed/destroyed with Python API
* Fixed backward reading of OPREC files when data losses occurred
* Fixed consecutive data logger acquisitions after frame configuration modifications
* Fixed data logger pre-trigger reconfiguration while the simulation is running (specific case: original value = 0, new value != 0)
* Fixed target crash when opening the Data Logger menu while simulation is running on CentOS
* Fixed unsaved sensor configuration when saving the model
* Fixed removing UCM definition files from the \_hyp folder when the last UCM of its kind is deleted from the model
* Fixed display issue showing empty sensor list when moving a column in the summary view
* **Modbus Master**: Fixed issues occurring with error codes 32 and 9
* **OPAL-RT Boards**: Fixed display issue showing wrong file when fetching bitstream file information

### Breaking changes

* Removed possibility to manually modify breaker status with CTRL+ALT+RIGHT CLICK when its Control type is set to External and simulation is running
* **IEC 61850**: Removed interface pre-configuration when adding a new interface to a project

### Known issues

N/A

***

## Version: 2020.1

### New features

* Added new machine library models:
  * Synchronous machine (pu fundamental)
  * Synchronous machine (pu standard)
  * PMSM
* Added new protection library model 25 Synchronism-Check
* Added new machine control library model PSS4B
* Added new Control Measurements and Control Miscellaneous components:
  * Fourier analysis
  * Fundamental
  * Mean
  * Mean, variable frequency
  * PI with anti-windup
  * Pos-seq, variable frequency
  * Power, 1-ph
  * Power, 3-ph
  * Power, instantaneous
  * Power, pos-seq
  * Power, pos-seq variable frequency
  * Sequence analyzer
* Added new example models
  * FACTS & HVDC | STATCOM
  * Protection | Out of Step Detection using PMUs
  * Protection | Transformer differential
* Added global preferences to specify the default system unit (SI/PU/PQ/A) per component type
* Added various advanced preferences in the simulation settings
* Added TrigOut observable to POW component and a mask parameter to define the pulse duration
* Added handles in the UCM structure to manage solver iterations
* Added support for relative paths for files defined in the I/O configuration tool
* Added validation step when closing the UCM builder to warn the user of unsaved changes
* Added Delete function in TestView
* **ABB PS935**: Added support for configuration via GUI
* **C37.118 Master**: Added option to configure local UDP port
* **OPAL-RT Board**: Added support for time-averaged digital inputs
* **OPAL-RT Board**: Added support for PWM-synchronized analog inputs
* **OPAL-RT Board**: Added support for .opbin bitstream configuration file extension
* **FPGA-Based simulation**: Added example model Transportation - FPGA-Based PMSM Drive

### Improvements

* Improved display of parameters in mask of RLC, sources and tools when switching between 1-phase and 3-phase connection
* Improved Sensor window view
* **OPAL-RT Board**: Improved browsing of .opal/.bin/.opbin files

### Bug fixes

* Fixed display issues when the Windows preference for size of text and apps is not set to 100%
* Fixed unresponsive I/O configuration tool when host IP address changes
* Fixed various stability issues when host PC is connected to a VPN
* Fixed non-persisting frequency parameter value in the load flow window when closing a design
* Fixed synchronization of "Perform load flow and set initial conditions at simulation start" box between load flow and simulation settings views
* Fixed Simulink import file browser filter indicating wrong supported version range
* Fixed base voltages of Benchmark example models HVAC\_6Bus\_230kV and HVAC\_38Bus\_735kV
* Fixed sensor file automatic load in DNP3\_MASTER\_SLAVE example model
* Fixed topology category in the netlist for Voltage Source Converters
* Fixed issue with the auto-transformer in the load flow calculations
* **IEC 61850**: Fixed scenario when the SVID has more than 126 bytes and/or when there are more than 16 channels configured per ASDU
* **IEC 61850**: Fixed import of projects created on a different host PC
* **IEC 61850**: Fixed IED and GOOSE ID auto-filling based on the SCL file
* **OPAL-RT Board**: Fixed random voltage output on unused analog output channels
* **OPAL-RT Board**: Fixed disregarded 'Initial phase' value when 'Output complementary' is checked on digital outputs

### Known issues

N/A


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/hypersim/readme/release-notes-2020.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.