> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/ni-slsc-modules/digital-bidirectional-modules/op8910-description.md).

# OP8910 Description

32-channel high-speed digital input and output (DIO) conditioning module with optional fault insertion unit (FIU) .

<figure><img src="https://2438675663-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FrYR5dUDCbEE35IWamogp%2Fuploads%2FXOan60hv9oa9NlcIwGvv%2Fimage.png?alt=media&amp;token=ec05c843-dd64-47e1-a85a-773258ec6b93" alt=""><figcaption></figcaption></figure>

The **OP8910** SLSC module is a **32 high-speed digital input and output** module with TTL/LVTTL (5.0V, 3.3V) output and galvanic isolation. Fault Insertion Unit (FIU) is optional.

## Key features <a href="#key-features" id="key-features"></a>

* Signal conditioning and FIU on a single board.
* Low latency < 20 ns, high resolution of 10 ns with 100 MHz FPGA.
* Digital in programmable threshold 0-50 V.
* Digital out TTL, max output current: 32 mA/ch or 800 mA total combined
* Fault insertions module FIU as an option

## Module architecture <a href="#board-architecture" id="board-architecture"></a>

The module features a combination of 32 input and output channels and a set of relays adding fault insertion capability for each signal.

The general layout of the board is as follows, with the **front interface connectors** on the **left** and the **SLSC backplane connectors** on the **right**.

<figure><img src="https://2438675663-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FrYR5dUDCbEE35IWamogp%2Fuploads%2FoERSVr6gqxnAmzTCFPzt%2Fimage.png?alt=media&amp;token=322f25e1-370c-496f-8130-39bcf1cbed2e" alt=""><figcaption></figcaption></figure>

\
The input/output conditioning is managed by one of these OPAL-RT I/O modules depending on the [configuration](#op8910-configurations):

* [OP5367-1](https://www.opal-rt.com/docs/op53xx/digital-output-modules/op5367-1-description.md) (32 DO)
* [OP5367-3](https://www.opal-rt.com/docs/op53xx/digital-bidirectional-modules/op5367-3-description.md) (16 DI and 16 DO)
* [OP5367-5](https://www.opal-rt.com/docs/op53xx/digital-input-modules/op5367-5-description.md) (32 DI)

A CPLD (Complex Programmable Logic Device) is used to configure the fault insertion unit (FIU) section and the OP5367-3 module.  It is responsible for the communication of the SLSC module within the NI environment for identification, error reporting, etc. It also receives configuration from the software and applies it to the FIU and to some of the I/Os.

The [FIU specification and topology](https://www.opal-rt.com/docs/ni-slsc-modules/op8900-slsc-modules-overview/modules-and-fiu-description.md#fault-insertion-unit-fiu-description) are common to all OP8900 boards.

## Input channel architecture <a href="#input-channel-architecture" id="input-channel-architecture"></a>

The input channels are located on the OP5367 mezzanine. The voltage range is 0-50V. Both high and low voltages are programmable per group of 8 channels over the whole range.

The channels are protected for ±50 VDC and ±50 VAC.

<figure><img src="https://2438675663-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FrYR5dUDCbEE35IWamogp%2Fuploads%2FZwXtpYfbyjkvqCKEeFTt%2Fimage.png?alt=media&amp;token=a43bdf7e-752c-4ed2-b71f-aea1abc8553b" alt=""><figcaption></figcaption></figure>

## Output channel architecture <a href="#output-channel-architecture" id="output-channel-architecture"></a>

The output channels are located on the OP5367 mezzanine. Their electronic circuit is presented below.

The channels are single-ended and LVTTL (3.3 V) or TTL (5 V) compliant (see the page[ Configuration and Installation](https://www.opal-rt.com/docs/ni-slsc-modules/digital-bidirectional-modules/op8910-description/configuration-and-installation.md) for voltage selection)  They are protected in case of short circuits.

<figure><img src="https://2438675663-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FrYR5dUDCbEE35IWamogp%2Fuploads%2F7uuQ8hrjmPo8XDJNaFr3%2Fimage.png?alt=media&amp;token=5245c366-2168-4008-9f85-d73d1f32559e" alt=""><figcaption></figcaption></figure>

{% hint style="info" %}
Initial values and complementary outputs are not managed by the OP5367.
{% endhint %}

## Available configurations <a href="#op8910-configurations" id="op8910-configurations"></a>

Several assemblies of the OP8910 are available, as listed below, with different numbers of inputs and outputs, and with or without the FIU section populated.

<table><thead><tr><th>Vendor Part #</th><th>Description</th><th width="79.199951171875">Digital In</th><th width="80">Digital Out</th><th>I/O module</th><th width="80">Digital Out Type</th><th>FIU</th></tr></thead><tbody><tr><td><strong>OP8911-F</strong></td><td>32 Dout LVTTL/TTL with FIU SLSC Conditioning Board</td><td>0</td><td>32</td><td><a href="https://www.opal-rt.com/docs/op53xx/digital-output-modules/op5367-1-description.md"><strong>OP5367-1</strong></a><br>(126-0616)</td><td>TTL</td><td>32 single-ended FIU</td></tr><tr><td><strong>OP8911-N</strong></td><td>32 Dout LVTTL/TTL SLSC Conditioning Board</td><td>0</td><td>32</td><td><a href="https://www.opal-rt.com/docs/op53xx/digital-output-modules/op5367-1-description.md"><strong>OP5367-1</strong></a><br>(126-0616)</td><td>TTL</td><td>N/A</td></tr><tr><td><strong>OP8913-F</strong></td><td>16 Din/16 Dout LVTTL/TTL with FIU SLSC Conditioning Board</td><td>16</td><td>16</td><td><a href="https://www.opal-rt.com/docs/op53xx/digital-bidirectional-modules/op5367-3-description.md"><strong>OP5367-3</strong></a><br>(126-0602)</td><td>TTL</td><td>32 single-ended FIU</td></tr><tr><td><strong>OP8913-N</strong></td><td>16 Din/16 Dout LVTTL/TTL SLSC Conditioning Board</td><td>16</td><td>16</td><td><a href="https://www.opal-rt.com/docs/op53xx/digital-bidirectional-modules/op5367-3-description.md"><strong>OP5367-3</strong></a><br>(126-0602)</td><td>TTL</td><td>N/A</td></tr><tr><td><strong>OP8915-F</strong></td><td>32 Din with FIU SLSC Conditioning Board</td><td>32</td><td>0</td><td><a href="https://www.opal-rt.com/docs/op53xx/digital-input-modules/op5367-5-description.md"><strong>OP5367-5</strong></a><br>(126-0604)</td><td>N/A</td><td>32 single-ended FIU</td></tr><tr><td><strong>OP8915-N</strong></td><td>32 Din SLSC Conditioning Board</td><td>32</td><td>0</td><td><a href="https://www.opal-rt.com/docs/op53xx/digital-input-modules/op5367-5-description.md"><strong>OP5367-5</strong></a><br>(126-0604)</td><td>N/A</td><td>N/A</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/ni-slsc-modules/digital-bidirectional-modules/op8910-description.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.