> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components.md).

# Description and Components

## Description <a href="#description" id="description"></a>

The OP1400PR PHIL Prime Series test benches are built around **high-quality 40U cabinets** which allow for **easy maintenance**, **repair** and **upgrade** over time.

They incorporate **multiple OPAL-RT rack-mountable products** to provide a **complete Power Hardware-in-the-Loop (PHIL) solution**.

The **OPAL-RT OP1400PR series of PHIL test benches** are **pre-assembled** and **optimized** units for **academia** and **industry**.

All test benches are compatible with [**RT-LAB**](https://www.opal-rt.com/docs/rt-lab) and [**HYPERSIM**](https://www.opal-rt.com/docs/hypersim).

The **available OP1400PR configurations of PHIL test benches** are:

* OP1400PR-10
* OP1400PR-10-LP
* OP1400PR-20
* OP1400PR-20-LP
* OP1400PR-30
* OP1400PR-30-LP
* OP1400PR-30-HP
* OP1400PR-30-LPHP
* OP1400PR-60
* OP1400PR-60-LP
* OP1400PR-60-HP
* OP1400PR-60-LPHP

## Components

Each model is composed of a common set of **base components**, along with **additional components that vary depending on the specific configuration**.

### **Base components**

The base components are **included in all test benches** of the OP1400PR series. Each cabinet includes the following components:

* An [**E-stop**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/emergency-stop-module.md) (emergency stop) **module**
* One [**power distribution unit (PDU)**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/power-distribution-unit-pdu.md) with a **lockable disconnect** **switch** and integrated **overcurrent protection**, interfacing with a **3-phase 380-480 V AC mains input.**
* A **central copper bus bar** providing a **common protective earth connection** for all installed components
* A dedicated **high-performance Ethernet switch**
* **AC power outlets** for internal power distribution to the installed components

### Variable components

The variable components are model-dependent. The variable components are:

* An **OPAL-RT real-time simulator** (see the **Hardware Platforms** in **top navigation bar**)
* One or more [**OP8110 4-quadrant (4Q) power amplifiers**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier.md)
* One or more programmable [**ITECH DC power supplies**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/dc-power-supply.md)
* One or two [**output interface modules**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/output-interface-module.md)
* [**LP**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/lp-bus-bar-module.md) (low power) or [**HP**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/hp-bus-bar-modules.md) (high power) **smart bus bar modules**\
  The model suffix identifies the installed **smart bus bar configuration**, e.g., OP1400PR-60-HP.\
  The **absence of a suffix** indicates that **no smart bus bar is installed**.
  * **-LP**: one LP bus bar
  * **-HP**: one HP bus bar
  * **-LPHP**: one LP bus bar and one HP bus bar

The physical location of the major components is illustrated in the figure below.

{% hint style="info" %}
The **AC power outlets** and the **Ethernet switch** are located at the **rear of the cabinet**.
{% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FzQhlSwYeVFgI67nD0Wmi%2Fimage.png?alt=media&amp;token=721a7c1c-ca31-4891-aec7-619bed66c909" alt="" width="434"><figcaption><p><em>Note that the actual test bench may slightly differ in appearance.</em></p></figcaption></figure>

## OP1400PR PHIL test bench model comparison <a href="#op1400pr-phil-test-bench-models" id="op1400pr-phil-test-bench-models"></a>

<table data-search="false"><thead><tr><th></th><th>OP1400PR-10</th><th width="151">OP1400PR-20</th><th width="151.333251953125">OP1400PR-30</th><th>OP1400PR-60</th></tr></thead><tbody><tr><td> </td><td><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FmGxJBVp8GYOTctc3bUGY%2Fimage.png?alt=media&amp;token=73488472-9f8c-4973-b544-92bfe4730b71" alt="" data-size="original"></td><td><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FqsxgIEqLQlqTiQIqnPwI%2Fimage.png?alt=media&amp;token=6ce2f61e-797b-4dbc-b263-0b3a5e380654" alt="" data-size="original"></td><td><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FSUdyRa27FeG7jrPyHzP5%2Fimage.png?alt=media&amp;token=722b1c0a-c7bf-4134-8c2a-4476f28bbc19" alt="" data-size="original"></td><td><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FHzioVmdTtk1tHMog9qaA%2Fimage.png?alt=media&amp;token=a54fb5ec-72de-4cc3-80a7-2b60b1abfa9e" alt="" data-size="original"></td></tr><tr><td><strong>E-stop module</strong></td><td>1</td><td>1</td><td>1</td><td>1</td></tr><tr><td><strong>Output interface module</strong></td><td>1</td><td>1</td><td>1</td><td>2</td></tr><tr><td><strong>Smart bus bar configurations</strong></td><td>OP1400PR-10-LP</td><td>OP1400PR-20-LP</td><td>OP1400PR-30-LP<br>OP1400PR-30-HP<br>OP1400PR-30-LPHP</td><td>OP1400PR-60-LP<br>OP1400PR-60-HP<br>OP1400PR-60-LPHP</td></tr><tr><td><strong>PDU</strong></td><td>1</td><td>1</td><td>1</td><td>1</td></tr><tr><td><strong>OP8110 amplifier</strong></td><td>1 × OP8110-3</td><td>1 × OP8110-6</td><td>1 × OP8110-6<br>1 × OP8110-3</td><td>3 × OP8110-6</td></tr><tr><td><strong>DC power supplies</strong></td><td>1 × IT6006C-500<br>6 kW, 500 V</td><td>1 × IT6012C-500<br>12 kW, 500 V</td><td>3 × IT6006C-500<br>6 kW, 500 V</td><td><p>3 × IT6012C-500</p><p>12 kW, 500 V</p></td></tr><tr><td><strong>Single-phase power bars (120 V/15 A or 220 V/10 A)</strong></td><td>2</td><td>2</td><td>2</td><td>2</td></tr><tr><td><strong>Required dedicated mains supply</strong></td><td>3-phase 380-480 V<sub>L-L rms</sub> 18 A</td><td>3-phase 380-480 V<sub>L-L rms</sub> 30 A</td><td>3-phase 380-480 V<sub>L-L rms</sub> 30 A</td><td>3-phase 380-480 V<sub>L-L rms</sub> 60 A</td></tr><tr><td><strong>Base model rated power</strong><br>3-phase, 120/208 V<sub>rms</sub></td><td>1 × 5 kW</td><td>2 × 5 kW</td><td>3 × 5 kW</td><td>6 × 5 kW</td></tr><tr><td><strong>Base model rated power</strong><br>3-phase, 240/415 V<sub>rms</sub></td><td>Not applicable</td><td>Not applicable</td><td>1 × 10 kW</td><td>2 × 10 kW<strong>*</strong></td></tr><tr><td><strong>Base model rated power</strong><br>400 V DC</td><td>1 × 5 kW</td><td>2 × 5 kW</td><td>3 × 5 kW</td><td>6 × 5 kW</td></tr><tr><td><a data-footnote-ref href="#user-content-fn-1"><strong>DUT</strong></a> <strong>connections</strong></td><td>3 × 30 A, banana connectors</td><td>3 × 30 A, banana connectors</td><td>3 × 30 A, banana connectors (-LP)<br><br>2 × 100 A, screw connectors (-HP)<br><br>3 × 30 A, banana connectors and<br>2 × 100 A, screw connectors (-LPHP)</td><td>3 × 30 A, banana connectors (-LP)<br><br>2 × 100 A, screw connectors (-HP)<br><br>3 × 30 A, banana connectors and<br>2 × 100 A, screw connectors (-LPHP)</td></tr><tr><td><strong>Maximum bus power</strong><br>3-phase, 120/208 V<sub>rms</sub></td><td>5 kW</td><td>10 kW</td><td>15 kW</td><td>30 kW</td></tr><tr><td><strong>Maximum bus power</strong><br>3-phase, 240/415 V<sub>rms</sub></td><td>Not applicable</td><td>Not applicable</td><td>10 kW</td><td>20 kW</td></tr><tr><td><strong>Maximum bus power</strong><br>400 V DC</td><td>5 kW</td><td>10 kW</td><td>15 kW</td><td>30 kW</td></tr></tbody></table>

\* *Available in back-to-back operation mode only.*

[^1]: Device under test


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.