# Connect the Test Bench

The **majority of the cables** are **available**, **labeled**, and **organized within the cabinet**. One of their ends is already connected. Simply remove the protective bubble wrap.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fugk1KuQL5tEvKocFHQms%2Fcabinet.png?alt=media&amp;token=af6c7c1b-3510-4d49-9906-8d18fd61e688" alt=""><figcaption><p><strong>Example</strong> of the inside of a cabinet at receiving</p></figcaption></figure>

The remaining cables are supplied as individual components. They ought to have been unpacked during the [unboxing](https://www.opal-rt.com/docs/op1400pr/get-started/install-the-test-bench.md) process.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F2xeezEaWdSniGXYI7X0s%2FOP1400PR%20parts.png?alt=media&amp;token=d57d99bd-fe80-4db0-add2-657a24bd8a7c" alt=""><figcaption><p><strong>Example</strong> of parts provided with the test bench</p></figcaption></figure>

{% hint style="info" %}
Be advised that these are all general  directives. Diagrams, instructions, and system-specific information are available in two PDF documents on the <mark style="background-color:$danger;">USB key provided with your system</mark>. **Take time to examine these documents prior to linking your system**.

* <mark style="background-color:$danger;">System Specification Document</mark>
* Overview of Connections and Signals (see examples below)
  {% endhint %}

{% tabs %}
{% tab title="Connection overview" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fr0u95i5DV2Uvr0W3nhc3%2Fimage.png?alt=media&amp;token=625e7caf-0129-4911-bc7f-f92f451fb9b0" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="Terminal block pinout" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FpPfQVrMBSAHjCaT4eXOC%2Fimage.png?alt=media&amp;token=e55bc634-cffc-4a50-b660-4926eb184cf9" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="Emergency stop chain" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FSHIZQaUrJMvx3VCnIlbN%2Fimage.png?alt=media&amp;token=0172c2e3-9739-41e7-bf21-fd6419cbf94a" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="Cabinet AC power path" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FG3ORj45RT7P2iLDzPkWm%2Fimage.png?alt=media&amp;token=7c68dbba-10c0-4291-8fdf-a0ae2099572b" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="ITECH connections" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FdFJ28nl2jiTwDjNQZgrZ%2Fimage.png?alt=media&amp;token=13fde242-090c-4d32-a402-512e8b615cbe" alt=""><figcaption></figcaption></figure>
{% endtab %}
{% endtabs %}

{% hint style="danger" %}
The **electrical installation** of the OP1400PR test bench **must only be done by qualified personnel**.
{% endhint %}

{% hint style="info" %}
Observe the **recommended wiring sequence** below.
{% endhint %}

## Connect the grounding cables <a href="#grounding-all-the-boxes-in-the-cabinet" id="grounding-all-the-boxes-in-the-cabinet"></a>

**All ground cables** must be connected to the **ground terminals** of **all modules installed at receiving**.

All ground cables for the delivered installed modules in the cabinet have **already been connected**.

All the necessary grounding cables are **inside the cabinet** and **connected to the cabinet ground bus bar**.

### Connect the ground terminals of the OP8110 amplifiers <a href="#grounding-of-op8110-amplifiers" id="grounding-of-op8110-amplifiers"></a>

* For each OP8110 amplifier, look in the cabinet for a ground cable labeled **113-1311** and named "**Cable\_GND\_12AWG**".

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FiQRXzPT4df5AO3qUdWVQ%2F113-1311%20rev%201.0%20groud%20cable.png?alt=media&amp;token=485ec357-910f-4696-9033-233a5da69127" alt="" width="563"><figcaption></figcaption></figure>

* Insert a ground cable into **each amplifier's ground screw** and **tighten firmly**.

{% tabs %}
{% tab title="OP1400PR-10" %}

* Connect **1 ground cable**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fn6a4ohp1wGlfMdRrqDoH%2Fimage.png?alt=media&amp;token=245188a1-c1ac-4295-9710-56aad05c11e6" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-20" %}

* Connect **1 ground cable**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FH0ic3mZ4Mh0y02OMnvfP%2Fimage.png?alt=media&amp;token=1e4016b5-1882-4b3b-81a0-6dc802682d84" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-30" %}

* Connect **1 ground cable** to **each OP8110 amplifier** for a **total of 2**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FCStb3jg7fFfJJ6Fw7HSp%2Fimage.png?alt=media&amp;token=c448cae4-102f-4813-98d2-1d759537269b" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-60" %}

* Connect **1 ground cable** to **each OP8110 amplifier** for a **total of 3**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FphoFR0yslKUIouIUzuKv%2Fimage.png?alt=media&amp;token=f3112818-1fc6-4b4e-aa1b-3db957bb8856" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}
{% endtabs %}

### Connect the auxiliary power inputs of the OP8110 amplifiers <a href="#connection-from-the-pdu-aux-connectors-to-the-auxiliary-power-inputs-of-the-op8110-amplifiers" id="connection-from-the-pdu-aux-connectors-to-the-auxiliary-power-inputs-of-the-op8110-amplifiers"></a>

**Each OP8110 group** (OP8110-3 has one group, OP8110-6 has two) **requires a dedicated auxiliary supply cable**.

One end of each AUX cable (marked “**PDU\_AUX**”) is already connected to a PDU's AUX outlet.

* **Locate all free ends** of auxiliary supply cables tagged **113-1732** in the cabinet, identified as "**AMP\_AUX\_POWER**".

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FibX7VwH1jk80UwPh7vOI%2Fimage.png?alt=media&amp;token=578aa99c-102d-4207-9e25-5c6ea72de893" alt=""><figcaption></figcaption></figure>

* **Connect the free ends of the AUX cables** marked **“AMP\_AUX\_POWER**” to **each OP8110 connector labeled** “**AUX 12V.**” Depending on your model, you may need to connect one to six auxiliary power input cables.

{% hint style="danger" %}
Make sure the connectors and auxiliary connector receptacles are **properly aligned**. **If you force the connections**, **the PDU or OP8110 amplifier may be severely damaged and require repair**.
{% endhint %}

{% tabs %}
{% tab title="OP1400PR-10" %}

* 1x OP8110-3 (1 AUX cable)
* Connect **1 AUX cable**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FdHmMDZwCWN4ceks02IF3%2Fimage.png?alt=media&amp;token=f6547da5-1d3e-41a6-9fee-46ac867e574f" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-20" %}

* 1x OP8110-6 (2 AUX cables).
* Connect a total of **2 AUX cables**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F82h5lf1GQA3LduEgdVwl%2Fimage.png?alt=media&amp;token=9e896243-4ec6-4605-aad6-41426ecfe82c" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-30" %}

* 1x OP8110-3 (1 AUX cable)
* 1x OP8110-6 (2 AUX cables)
* Connect a total of **3 AUX cables**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FJLHlwShORIKwZWG9Ll2I%2Fimage.png?alt=media&amp;token=a73ec625-99a4-4d28-8500-f074f669bd95" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-60" %}

* 3x OP8110-6 (2 AUX cables)
* Connect **2 AUX cables per amplifier** for a **total of 6**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F3aSs9s6M0k7XfFyPA5zC%2Fimage.png?alt=media&amp;token=eee20062-fdcf-4680-b419-13e3fdee1647" alt="" width="563"><figcaption></figcaption></figure>
{% endtab %}
{% endtabs %}

## Connect high-voltage cables <a href="#high-voltage-wiring" id="high-voltage-wiring"></a>

The PDU is at the heart of the test bench power system, receiving three-phase AC mains and distributing power to the ITECH power supplies and OP8110 amplifiers in a safe, controlled and protected manner.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FfHPVcVOm6aYftzk1rwLy%2Fimage.png?alt=media&amp;token=e1db53db-c4d6-4dad-b406-f3579e3b78fd" alt=""><figcaption></figcaption></figure>

### 3-phase mains supply point provided by the customer <a href="#installation-of-the-customer-three-phase-mains-supply-point" id="installation-of-the-customer-three-phase-mains-supply-point"></a>

The **customer** is **responsible** for providing **three-phase AC mains supply points** (rated per project specifications), located within reach of the cabinet's input power connections, and **in accordance with all applicable electrical standards**.

{% hint style="danger" %}
**WARNING: There is a risk of fire or electric shock.**

The electrical installation of the **three-phase AC mains supply** must be performed **only by qualified personnel** (e.g., a certified electrician or a customer-authorized lab technician) and must comply with **all applicable local electrical codes**.

Installation requirements typically include, but are not limited to:

* Installation of a **certified overcurrent protection device** (circuit breaker or fuse) on the AC mains supply to the equipment.
* **Proper sizing of conductors and overcurrent protection devices** in accordance with local codes and the equipment’s maximum rated current. As a **design guideline**, it is recommended to provide approximately **25% additional capacity** above the maximum specified current.
* Installation of a **clearly identified and easily accessible disconnection device** (such as a switch or circuit breaker) within reach of the equipment.

Failure to comply with all applicable safety/installation requirements could result in **serious injury, fire, or electric shock.**
{% endhint %}

### Connect the three-phase mains to the PDU. <a href="#connection-from-the-three-phase-mains-to-the-pdu" id="connection-from-the-three-phase-mains-to-the-pdu"></a>

Once the three-phase AC mains supply point is ready, the customer must **connect the supply lines to the cabinet's Power Distribution Unit (PDU)**.

Connect the PDU power terminals with a 4-wire cable (3 line conductors and 1 protective earth conductor).

The circuit must provide the following **voltage levels** and **frequency**:

* **Line-to-line voltage (RMS)**: 380–480 V, 3Φ
* **Frequency**: 47 Hz to 63 Hz

The circuit must be **rated for the maximum line current**, which depends on the supply voltage. For convenience, reference currents are provided for supply voltages of 380 V and 480 V.

| Models            | Maximum line current&#xA;380 V (RMS) | Maximum line current&#xA;480 V (RMS) |
| ----------------- | ------------------------------------ | ------------------------------------ |
| **OP1400PR-10\*** | 18 A                                 | 14 A                                 |
| **OP1400PR-20\*** | 30 A                                 | 24 A                                 |
| **OP1400PR-30**   | 30 A                                 | 24 A                                 |
| **OP1400PR-60**   | 60 A                                 | 48 A                                 |

**\*** For these models, the phase currents are unbalanced, so the specification is that of the worst-case line current.

{% hint style="danger" %}
**Hazardous voltage levels may exist on the PDU's main power terminals!**

Before connecting to the PDU, the **three-phase alternating current mains** must be completely **deenergized**, **locked out**, and **tagged**.
{% endhint %}

The power input terminals for the power cable connection are located behind a **removable cover** at the **PDU's rear**.

***

1. **Unscrew** the **two captive screws** that hold the cover in place. It is worth noting that **the cover has an integrated cable clamp**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FxCzBfwAyPLM7yC9Xshso%2Fimage.png?alt=media&amp;token=c7c9ae87-4b53-4cf4-b320-e3db335e97ad" alt="" width="563"><figcaption></figcaption></figure>

2. Place the **mains cable through the cable clamp**.
3. **Insert** and secure the conductors to the **input terminals** **L1, L2, L3, and GND**.
4. **Ensure** that **each conductor** is **fully inserted** and **properly tightened** according to the terminal specifications.
5. **Reinstall** the **terminal cover** and **tighten** the **two captive screws**.
6. **Tighten the cable clamp** to secure the incoming cable and provide strain relief.
7. **Attach the cable to the side of the cabinet** using **cable ties**, **routing it downward toward the lower part of the rear cabinet door**.
8. **Guide the cable** **out** through the **designated opening** in the **door**.

### Connect the PDU AC supply to the DC power supplies <a href="#pdu-ac-supply-to-the-dc-power-supplies" id="pdu-ac-supply-to-the-dc-power-supplies"></a>

All DC power supplies' AC input terminals must have their **AC supply cables** screwed in. The part number is **113-1731**, which is labeled “**Cable\_RingTerminal\_To\_PowerLok\_Plug**.”

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F1p3QgEwLw87gniYPf80E%2Fimage.png?alt=media&amp;token=49549236-50f8-410f-9697-14a0041b9127" alt=""><figcaption></figcaption></figure>

The **number of cables** required depends on the OP1400PR model.

* OP1400PR-10: 1 cable
* OP1400PR-20: 1 cable
* OP1400PR-30: 3 cables
* OP1400PR-60: 3 cables

Each power cable is **already connected to the PDU** on one end, with a connector to AC OUT 1, AC OUT 2, or AC OUT 3.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FvMUSPymC9X5USKKqko6O%2FPDU-AC-out-connectors.png?alt=media&amp;token=55436dc6-b9fb-42bf-a521-b9342b87f4b0" alt=""><figcaption></figcaption></figure>

{% columns %}
{% column width="50%" %}
The cable's other end has **three line wires** (<mark style="color:blue;">**blue**</mark>, <mark style="color:red;">**red**</mark>, and **black**) and a ground wire (<mark style="color:green;">**green**</mark>-<mark style="color:yellow;">**yellow**</mark>).

{% endcolumn %}

{% column width="50%" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FllTBnl1GqtyqM7Qs3xfy%2Fimage.png?alt=media&amp;token=6adab951-b0c9-4b5a-a1ae-1cdb0f57083b" alt="" width="375"><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

***

**Locate** the **cable ends** within the **cabinet**.

For each cable:&#x20;

1. **Unscrew** the **two screws** that hold the **protective cover** to the **rear** panel's AC input terminals.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FpcNMHnc5hHzWBIZ8Ijr6%2Fimage.png?alt=media&amp;token=545d63e3-8aeb-482a-bcd8-5e11dc1a436e" alt="" width="563"><figcaption></figcaption></figure>

2. **Connect** the **three wires of the line**.
   * <mark style="color:red;">**CAUTION**</mark><mark style="color:red;">: Because AC supply lines carry a high current, the connections must be properly tightened to avoid resistive connections that could overheat.</mark>
3. Connect the **ground cable** to the **screw** located at the **ground terminal**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FllTBnl1GqtyqM7Qs3xfy%2Fimage.png?alt=media&amp;token=6adab951-b0c9-4b5a-a1ae-1cdb0f57083b" alt="" width="563"><figcaption></figcaption></figure>

{% hint style="danger" %}
**OP1400PR-10 and OP1400PR-20**

* Connect the **three line wires** into the **3 terminals**. The order is not important.

**OP1400PR-30** and **OP1400PR-60**

* Be sure to **respect the color schemes** as in the image below.
* Ensure that **the AC phases are properly interleaved between the 3 power supplies** (as in the image) to **balance out the currents of the three phases**.
  {% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FZnSd3VnX8sJQxThjS67A%2Fimage.png?alt=media&amp;token=f3f250df-b539-490f-b821-eacb18dca01c" alt="" width="563"><figcaption><p>OP1400PR-30 and OP1400PR-60 wiring scheme</p></figcaption></figure>

4. **Screw** the **protective cover** into place.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FS57t6M0oeZFCjJZtUjB3%2Fimage.png?alt=media&amp;token=c2d5ec1d-75f9-4854-a832-346fd6a2b0dd" alt="" width="563"><figcaption></figcaption></figure>

### Connect the DC power supplies to the PDU <a href="#dc-supply-connection-between-the-dc-power-supplies-and-op8110-amplifiers" id="dc-supply-connection-between-the-dc-power-supplies-and-op8110-amplifiers"></a>

**Each DC power cable** is **already connected to the PDU** to one of the **DC IN1**, **DC IN2**, or **DC IN3** input connector.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FY9kUPF1aJNXCiS3XhpRj%2Fimage.png?alt=media&amp;token=ba2c4217-27b5-4b20-8334-0611cee1fc52" alt=""><figcaption></figcaption></figure>

**DC power supply cables** must be **screwed** onto the **DC output terminals** of all **DC power supplies**. They are identified as part number **113-1729**, which is labeled “**Vbatt\_Oring\_To\_PowerLok\_Plug**”

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FUIEmgUdNTyKKh3rBtkfo%2Fimage.png?alt=media&amp;token=a500bf44-ccbc-483d-96ff-47c6c816f77c" alt=""><figcaption></figcaption></figure>

The number of cables required depends on the OP1400PR model.

* OP140PR-10: 1 cable
* OP140PR-20: 1 cable
* OP140PR-30: 3 cables
* OP140PR-60: 3 cables

Find the **cable ends** in the cabinet. They are made up of <mark style="color:$danger;">**red (DC+)**</mark> and **black (DC-)** wires with **ring terminals**.

For the ITECH IT6000C DC power supply:

* **Remove** the **protective plastic cover** by **loosening the 2 screws** at the bottom.
* For **each terminal**, remove the screw, insert the ring connector of the wire, and **tighten back the screw** to the terminal.
  * **Ensure correct polarity**: **red cable** on <mark style="color:$danger;">**red terminal**</mark> <mark style="color:$danger;"></mark><mark style="color:$danger;">(DC+)</mark> and **black wire** on **black terminal** (DC-).

{% hint style="danger" %}
**CAUTION**: The DC supply lines carry **high currents**, so all connections must be **securely tightened** to **prevent resistive joints** that could **overheat**.
{% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FEJrFCoGThUtWfk0jz1Hj%2Fimage.png?alt=media&amp;token=ec8334cf-a933-4dff-82a4-b4906d5b4ae3" alt="" width="563"><figcaption></figcaption></figure>

* **Replace** the **protective cover** to protect against electric shock, then **tighten the two screws**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FJg41pNPOhGatFlZUXvgB%2Fimage.png?alt=media&amp;token=bc0d926a-b10d-4e78-af6e-ee28e82174bd" alt="" width="563"><figcaption></figcaption></figure>

#### Connect the DC supply cables from the PDU to the OP8110 amplifiers <a href="#dc-supply-connection-from-the-pdu-to-the-op8110-amplifiers" id="dc-supply-connection-from-the-pdu-to-the-op8110-amplifiers"></a>

Screw the **DC power supply cables** onto the **DC input terminals** of **all groups** of **all OP8110 amplifiers**.

The cables are identified as **113-1730** and labeled “**Cable\_RingTerminal\_To\_PowerLok\_Plug**.”

The **number of cables to connect** depends on the OP1400PR model.

* OP140PR-10: 1 cable
* OP140PR-20: 2 cables
* OP140PR-30: 3 cables
* OP140PR-60: 3 cables + 3 pairs of jumpers

**Each DC power supply cable** is **already connected to the PDU**'s outlet(s) DC OUT1, DC OUT2, or DC OUT3.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FGquRGOaMrlR7mS4Jmwhx%2FPDU-DC-out-connectors.png?alt=media&amp;token=0a724515-c984-4013-8264-38da34630b07" alt=""><figcaption></figcaption></figure>

{% columns %}
{% column %}
The **jumper cables** required for the **OP1400PR-60** are **black** and <mark style="color:$danger;">**red**</mark> cables with **banana plugs** on **both ends**, and they are supplied as separate parts under the part numbers **T00-9658** (**black**) and **T00-9659** (<mark style="color:red;">**red**</mark>).
{% endcolumn %}

{% column %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F0mHCCIn6U1CseCOZzuGX%2Fimage.png?alt=media&amp;token=eee8a4b5-42c9-4978-aff6-a082645b97cb" alt="" width="145"><figcaption><p>T00-9658</p></figcaption></figure>

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FkGocpplFhMC1xPWrAgpL%2Fimage.png?alt=media&amp;token=6eb90c33-921a-455e-9fb7-725d33f64811" alt="" width="152"><figcaption><p>T00-9659</p></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

***

{% columns %}
{% column %}
Determine where the **cables are in the cabinet**.

The cable ends you're looking for are made up of two <mark style="color:$danger;">**red**</mark> and **black** wires connected by **banana plugs**.
{% endcolumn %}

{% column %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FIAwofrOizb0b6B2Cb0I9%2FPowerLok-to-banana%20cable%20ends.png?alt=media&amp;token=0d3df681-5f4b-4403-9815-8b5b891c9adf" alt="" width="375"><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

**Connect each cable** to the **corresponding DC input terminals** of the **OP8110 amplifiers**, as illustrated below.

{% hint style="danger" %}
When connecting the banana plugs, **make sure the polarity is correct**: red banana plug in red terminal, black banana plug in black terminal.
{% endhint %}

{% tabs %}
{% tab title="OP1400PR-10" %}

* Connect one pair of banana plugs to the connectors **DC1**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FCfu7bWIBkw0fBOhDudWr%2Fimage.png?alt=media&amp;token=510fe0cb-a974-4f4e-984a-88c027fcc573" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-20" %}

* Connect one pair of banana plugs to the connectors **DC1**
* Connect one pair of banana plugs to the connectors **DC2**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fz4nPiRdpJzfBVzWB8847%2Fimage.png?alt=media&amp;token=d49f042b-2e5a-4542-a48f-9db794dadcb5" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-30" %}

* Connect one pair of banana plugs to connectors **DC1** of the **OP8110-6** (**top most** amplifier)
* Connect one pair of banana plugs to connectors **DC2** of the **OP8110-6** (**top most** amplifier)
* Connect one pair of banana plugs to connectors **DC1** of the **OP8110-3** (**bottom most** amplifier)

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FesbshhXzbhCkKmMyaKYy%2Fimage.png?alt=media&amp;token=9e21e7cf-5ac2-4b5a-a5fc-d5546f90c303" alt=""><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-60" %}

* Connect one pair of banana plugs to the **DC1** connectors of the top most **OP8110-6** amplifier
* Connect a provided <mark style="color:red;">**red jumper cable**</mark> (T00-9659) **from the DC1 to the DC2 connector** of the same amplifier
* Connect a provided **black jumper cable** (T00-9658) **from the DC1 to the DC2** connector of the same amplifier
* **Repeat the same steps** for the two other amplifiers

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FH9664scTSvwpdEcg0VU8%2Fimage.png?alt=media&amp;token=ae7a0991-f2a6-4715-afbf-79c4c98208fa" alt=""><figcaption></figcaption></figure>
{% endtab %}
{% endtabs %}

## Connect the synchronization cables on the OP8110 amplifiers <a href="#synchronization-cables-on-the-op8110-amplifiers" id="synchronization-cables-on-the-op8110-amplifiers"></a>

{% columns %}
{% column width="58.333333333333336%" %}
**Connect** the provided **optic-fiber synchronization cable** (T00-6615) between the OP8110 amplifiers on test benches **OP1400PR-30** and **OP1400PR-60** **only**, as illustrated below.

{% hint style="info" %}
Synchronization cables are not required for the OP1400PR-10 and OP1400PR-20 models, which have only one OP8110 unit.
{% endhint %}
{% endcolumn %}

{% column width="41.666666666666664%" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fln1FhR4AR2nsklbjW6yZ%2Fimage.png?alt=media&amp;token=e15f7bbc-d4be-4b90-bf8c-93c5fa507feb" alt="" width="212"><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

{% hint style="danger" %}
**CAUTION: Fiber-optic synchronization cables cannot be flexed or folded.**

If **excess length** must be managed, **gently coil the cables into a circular loop** with a **minimum diameter of 6 inches (150 mm)** and secure **without applying too much pressure**.

**The synchronization cables on the OP8110 should not be connected or disconnected while the amplifier is in operation. This could cause damage to the amplifier as well as void the warranty.**
{% endhint %}

{% tabs %}
{% tab title="OP1400PR-30" %}

* Connect the synchronization cable from the **Tx connector** of the **top unit** to the **Rx connector** of the **bottom unit**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FJZOeAcG9MbwTUoJt41X4%2FOP1400PR-30%20synchronization.png?alt=media&amp;token=0bcff591-a318-44cf-b381-c593636d8798" alt=""><figcaption></figcaption></figure>

{% endtab %}

{% tab title="OP1400PR-60" %}

* Connect the synchronization cable from the **Tx connector** or the **top unit** to the **Rx connector** of the **middle unit**
* Connect the synchronization cable from the **Tx connector** or the **middle unit** to the **Rx connector** of the **bottom unit**

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FBWmft09BbV4rcVT7ECVX%2FOP1400PR-60%20synchronization.png?alt=media&amp;token=846765e6-c796-406f-b718-2ad705a1180a" alt=""><figcaption></figcaption></figure>
{% endtab %}
{% endtabs %}

## Install the SFP cables <a href="#cable-routing" id="cable-routing"></a>

* For **each OP8110 amplifier** in your test bench, **connect** the **provided SFP cable** between the **OP8110 amplifier** (the **rightmost SFP port identified as GTP A**) and the **simulator**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FKvVYyDtIna3fieMp2w7J%2Fimage.png?alt=media&amp;token=74fb535a-dc53-466a-a22e-20f8fa8c88d7" alt="" width="563"><figcaption></figcaption></figure>

* OP1400PR-10: **1 SFP cable** to connect
* OP1400PR-20: **1 SFP cable** to connect
* OP1400PR-30: **2 SFP cables** to connect
* OP1400PR-60: **3 SFP cables** to connect (example below)

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FbNDTXkw1C2tA5u0AbFdQ%2Fimage.png?alt=media&amp;token=e282c7e9-a3d0-4102-9595-70dc43f497cc" alt="" width="510"><figcaption><p><strong>Example</strong>: 3 SFP cables to an OP5707XG simulator on an OP1400PR-60</p></figcaption></figure>

## Connect the power cables through the cabinet door <a href="#cable-routing" id="cable-routing"></a>

The **three-phase PDU input power cable**, as well as **both power cables** for the **single-phase power bars**, must **pass through the gap at the bottom of the OP1400PR chassis rear door**.

This allows the door to completely close during test bench operation.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F0NkhHVPcVmuYicYrnUEs%2Fimage.png?alt=media&amp;token=c587c875-0023-4217-977a-9ec1dc7a6e0b" alt=""><figcaption></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op1400pr/get-started/connect-the-test-bench.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.