> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/dc-power-supply.md).

# DC Power Supply

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fstr0rwUBPKYWueTOPNKs%2Fimage.png?alt=media&amp;token=44bb5ebd-225e-46d3-8e93-685b60cc5b77" alt="" width="563"><figcaption></figcaption></figure>

Download the ITECH bidirectional programmable DC power supply IT6000C Series User Manual below.

{% file src="/files/wmYvSQ544lLjNK4c5TFM" %}

## Description <a href="#description" id="description"></a>

The OP1400PR test benches are equipped with **ITECH IT6000C series bidirectional DC power supplies**. These **power supplies provide the** [**OP8110 4-Quadrant amplifiers**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier.md) with a constant **500 VDC input voltage** and allow the amplifiers to consume or to feed back power from/to the 3-phase mains input. The amount of power supply units and the power ratings of each unit have been especially chosen by OPAL-RT so that the test bench can deliver its full performance.

## Functional overview <a href="#functional-overview" id="functional-overview"></a>

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FeCKo4aM7QXOcC9LDUBva%2Fimage.png?alt=media&amp;token=07487dd5-18fa-4fc6-98ad-ce0194e45b92" alt=""><figcaption></figcaption></figure>

The IT6000C power supplies support many configurations and modes of operation. However, OPAL-RT recommends limiting the use of the power supplies to the following steps after turning them on:

* Set the **output voltage setpoint** using the **V-set button** \[#1], the **numerical keypad** and the **Enter button** to **500 V**.
* Set the **positive output current limit** using the **I-set button** \[#2], the **numerical keypad** and the **Enter button** to the **recommended maximum positive value** (see table below).
* Set the **negative output current** by pressing the **I-set button** \[#2] again and by configuring with the **numerical keypad** and the E**nter button** to the **maximum recommended negative value**\ <mark style="color:red;">Use the</mark> <mark style="color:red;"></mark><mark style="color:red;">**+/- button**</mark> <mark style="color:red;"></mark><mark style="color:red;">to set the sign to negative, see the table below</mark>.
* Turn on the output voltage using the **On/Off** button \[#3].

| Amount of OP8110 groups supplied per DC supply | Recommended maximum positive output current | Recommended maximum negative output current |
| ---------------------------------------------- | ------------------------------------------- | ------------------------------------------- |
| **1**                                          | 15 A                                        | -15 A                                       |
| **2**                                          | 30 A                                        | -30 A                                       |

{% hint style="danger" %}
Operating the IT6000C power supplies at different settings/limits than what is recommended by OPAL-RT may put personnel and equipment at risk!
{% endhint %}

## Specifications <a href="#specifications" id="specifications"></a>

Please refer to ITECH's website for detailed specifications and information on the DC power supply.

<http://www.itech.sh/en/product/dc-power-supply/IT6000C.html>.

## Settings <a href="#settings" id="settings"></a>

Chapter 5 of the ITECH power supply manual describes the basic functions and features. The user may find the “Power-on state” feature very useful when set on “Last-Off”:

**Set the power-on state:**

1. Press the composite keys **\[Shift]+\[P-set]** (System) on the front panel to enter the system menu.
2. Press the **Up/Down** key or turn the knob to select the Power On and press **\[Enter]**.
3. Press the **Left/Right** key or turn the knob to adjust the value of this parameter.

* **Reset**: Default value, indicates when the instrument is powered on, the instrument will initialize some parameter settings or state.
* **Last**: Indicates when powered on, the instrument will remain the same parameter settings and output status as last time you powered off the instrument.
* **Last+Off**: Indicates when powered on, the instrument will remain with the same settings as last time you powered off the instrument, but the output status is Off.

## On/Off synch cable <a href="#on-off-synch-cable" id="on-off-synch-cable"></a>

OP1400PR test benches, having more than one ITECH power supply, include an On/Off synchronization cable.

The synchronization cable allows you to link the On/Off functionality of multiple ITECH units. Pushing the On/Off button on one unit, will automatically change the On/Off status of the other units as well.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/dc-power-supply.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.