> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/power-distribution-unit-pdu.md).

# Power Distribution Unit (PDU)

## Description <a href="#description" id="description"></a>

The PDU receives a 3-phases 380-480 V AC input and distributes power to the test bench’s DC power supplies and amplifiers. It provides DC protection, monitoring, 24 V control power for the main contactor and bus bar modules, and 12 V auxiliary power for amplifier control circuits. The PDU integrates with the E-stop (emergency stop) module for safe start/stop operation and emergency shutdown.

It also features **three DC chopper circuits** to dissipate excess energy on power resistors in case of DC bus overvoltage.

## Controls and indicators <a href="#front-panel-led-indicators" id="front-panel-led-indicators"></a>

The controls and indicators are all located at the front of the PDU.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FxnPeziOrRAxuepDkIhSX%2Fimage.png?alt=media&amp;token=ea67fc0b-b02b-47b5-a76c-498a70a634a8" alt=""><figcaption><p>PDU control and status indicator LEDs</p></figcaption></figure>

* **Control**
  * Main power switch
* **Indicator LEDs**
  * **AC MAINS**: AC input status
  * **24 VDC ON**: 24 V control power status
  * **DC BUS ON**: DC bus active status
  * **CHOPPER ON**: DC chopper operation status

## Rear connectors and power interfaces <a href="#pdu-features" id="pdu-features"></a>

The connectors are all located at the back of the PDU.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FmUtagM4QIEt2F4HXWOVj%2Fimage.png?alt=media&amp;token=1372bc9d-74a1-49a3-9d06-7f7c74a7ad76" alt=""><figcaption><p>PDU connectors (rear)</p></figcaption></figure>

* 1x **internal AC supply**: 100-240 V AC connector (under the fan). It powers the internal 12 V and 24 V power supplies.
* 1x **ground terminal**: Rated voltage: 500 V to ground.
* 6x **AUX connectors:** Provide 12 VDC auxiliary power to the [OP8110 amplifiers](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier.md).
* 1x **P1 connector:** Interface to the [E-stop module](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/emergency-stop-module.md) for start, stop and emergency shutdown.
* 3x **DC OUT connectors:** Distribute DC power to the OP8110 amplifiers (see note 1).
* 3x **DC IN connectors:** Accept DC power from the DC power supplies (see note 1).
* 3x **AC OUT connectors:** Supply AC power to the ITECH DC power supplies (see note 1).
* 1x **main power terminals (L1, L2, L3, GND):** Rated up to 60 A for the 3-phase 380-480 V AC input.

**Note 1:** The PDU supports power distribution to up to **three** [**ITECH DC power supplies**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/dc-power-supply.md) and can deliver the corresponding DC output to up to **three** [**OP8110-6 amplifiers**](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier.md#op8110-6).

## Simplified electrical schematic <a href="#electrical-schematic" id="electrical-schematic"></a>

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FBWVmQjXH4YwhExcmS79U%2Fimage.png?alt=media&amp;token=95d6a9a8-ae14-42c0-a92d-eae634689f75" alt=""><figcaption><p>PDU electrical schematic</p></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/power-distribution-unit-pdu.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.