> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op1400pr/operate-the-test-bench/control-and-monitor-the-test-bench.md).

# Control and Monitor the Test Bench

## Overview <a href="#overview" id="overview"></a>

The **user interface (UI)** of the **OP1400 Prime Dashboard**, which is accessible through RT-LAB, is simple to use and allows for **parameter setting**, **test bench control**, and **signal monitoring**.

**All OP1400PR test bench models** share a **similar dashboard layout** and **configuration workflow**.

{% columns %}
{% column width="33.33333333333333%" %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FqMPWLJqTH7bQsptaR4Sb%2Fimage.png?alt=media&amp;token=c35e878d-9a2b-4366-995d-eb5c4cb04475" alt=""><figcaption></figcaption></figure>
{% endcolumn %}

{% column width="66.66666666666667%" %}
The **primary menu** is the **left side bar menu**. It is **similar for all models**, but **it varies slightly** depending on the model.

* Note that the **OP1400PR-10** has no **left side bar menu**.
  {% endcolumn %}
  {% endcolumns %}

## Main Panel menu <a href="#main-panel-menu" id="main-panel-menu"></a>

The **Main Panel** menu includes all the tabs below.\
The **tabs** are the **same** for **all OP1400PR** models.\
This is the only menu with multiple tabs.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FGuRnWwmfe3N4AJTAD7G5%2Fimage.png?alt=media&amp;token=a01a8b55-c722-4112-aa6b-d387f2b0506b" alt=""><figcaption><p>OP1400PR-60 dashboard with left side bar menu and tabbed menu</p></figcaption></figure>

## MasterCtrl tab <a href="#masterctrl-tab" id="masterctrl-tab"></a>

This tab is the **master control (MasterCtrl) panel**. It will be displayed in the **Main Panel** menu.

The **common panel elements** are described in the **first tab** below. **Specific model features** are **described in their respective tabs**.

{% tabs %}
{% tab title="Common features" %}

### Enable or disable an amplifier DC bus group <a href="#enable-or-disable-an-amplifier-dc-bus-group" id="enable-or-disable-an-amplifier-dc-bus-group"></a>

To **use** the **DC bus** of a **group** from any **OP8110 power amplifier**, it needs to be **enabled** and **precharged**. Refer to this section for details: [OP8110 4Q Power Amplifier](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier.md#dc-precharge)

* To **enable a DC bus**, press the corresponding **DC bus on/off** **button**.
  * The button status changes to “On”.
  * If the **DC bus precharge is successful**, the **status indicator** will light <mark style="color:green;">**green**</mark>.
* To **disable** a specific **DC bus group**:
  * Press the corresponding **DC Bus on/off** button.
  * The button status changes to “**Off**”.
  * The **status indicator** turns off.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FO8z56uW5LicUUa9FnDST%2Fimage.png?alt=media&amp;token=a8c367cb-7954-4280-a6ef-6feb5134b108" alt="" width="347"><figcaption><p><strong>Example</strong>: OP1400PR-60 Group 1 and Group 2</p></figcaption></figure>

### View the operating group mode

The **group mode** is **set** in the [**OP1400PR-*****nn*****&#x20;UI block**](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md), in the [**Global Parameters section**](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md#global-parameters) of each **amplifier tab.**

In the **control user interface**, the **group mode** is displayed **under each group**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FgVLPo6OKDgLnTQjKzYET%2Fimage.png?alt=media&amp;token=f7294b98-d8ef-4361-8102-31c910cd6b78" alt="" width="375"><figcaption><p><strong>Example</strong> : OP1400PR-60 Group 1 of an OP8110-6 is operating in<br>independent AC mode</p></figcaption></figure>

### Enable or disable an individual phase line <a href="#enable-or-disable-an-individual-phase-line" id="enable-or-disable-an-individual-phase-line"></a>

**Each phase line** of **each group** of **all amplifiers** can be **enabled** or **disabled** **individually**.

* To **enable a line**, press the corresponding **phase line on/off** **button**.
  * The **button status** changes to “**On**”.
  * If the **DC bus precharge is successful**, the **status indicator** will light <mark style="color:green;">**green**</mark>.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FrAoz2qFFwkjfKC9Y9Mbi%2Fimage.png?alt=media&amp;token=32b996cc-b02c-4589-a0de-c29615c07f7f" alt="" width="338"><figcaption><p>L1 to L2 are on and outputs are switched.<br>L4 to L6 are off.</p></figcaption></figure>

### Change the group reference source <a href="#change-the-group-reference-source" id="change-the-group-reference-source"></a>

The user can easily **change** the **reference source** for a group. The reference applies to the whole **group**.

{% hint style="danger" %}
**It is recommended not to switch the reference source on the fly in realtime** **when the reference signal magnitude (voltage/current) is not set to zero**.

Before changing the source, the user needs to bring the reference magnitude (voltage/current) to zero.
{% endhint %}

* When the **magnitude is at zero**, select a **reference source** from the drop-down list. Choices are:
  * CPU
  * FPGA
  * Analog IN
  * eHS

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FdZYO8zTFaoulrlwSA0HE%2Fimage.png?alt=media&amp;token=ae4ac5ad-a6bf-488b-9bb9-e2b3f06b9332" alt="" width="244"><figcaption></figcaption></figure>

### Change the group internal CPU/FPGA reference

For **each group** the user can **change** the **magnitude** and the **frequency** of the internal reference.

In the **OP1400PR-*****nn*****&#x20;UI block** the user has already set the mode of operation and the reference type.

If the user selects the [**internal reference**](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md#sidebar-parameters), then the **magnitude** and **frequency** of the **reference signal** can be **controlled with these input fields**.

Based on the user's mode of operation setting, the **unit** of the **reference magnitude** is displayed:

* If the user selected **voltage mode** for a group it will **display** **\[V]**
* If the user selected **Current mode** for a group, then it will **display \[A]**.

To **change a value of a field**, **enter a value** or use the **up and down arrow keys**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FdoTY636Md6Sm4Z9voPSg%2Fimage.png?alt=media&amp;token=be8da668-b08e-41da-b8ea-786ad163ade8" alt="" width="375"><figcaption></figcaption></figure>

### Identify and reset faults

If there is **any fault** on **any line output** then the **respective output fault indicator** turns <mark style="color:red;">**red**</mark>.

If it is a **global fault**, then the **middle square** indicator turns <mark style="color:red;">**red**</mark>. The fault status line is displayed across all dashboard tabs. Note that the **fault status display** appears in all the tabs of the **Main Panel**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FPHEhcmIbIy0hg3e43IgL%2Fimage.png?alt=media&amp;token=bc2eef42-e358-4684-b384-90cdeeb02615" alt="" width="347"><figcaption><p>#2 OP8110-6 shows no fault</p></figcaption></figure>

* **Identify the fault** by verifying your circuits, connections, units and DUT.
* See the section [Troubleshoot the Test Bench](https://www.opal-rt.com/docs/op1400pr/operate-the-test-bench/troubleshoot-the-test-bench.md).
* **Correct the fault** on the test bench set-up.
* **Reset the fault** by pressing the **Reset button** (non-latching).
* All **fault indicators** should **clear up**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FL2DRLBwbGBoZY8kdYT4X%2Fimage.png?alt=media&amp;token=3efe5414-c44c-4ee9-aed7-e535127a42bb" alt="" width="375"><figcaption></figcaption></figure>

{% hint style="info" %}
Don't forget[ to go back to the top of this section](#amplifier-control) and consult the specific features of your OP1400PR test bench in their respective tabs.
{% endhint %}
{% endtab %}

{% tab title="OP1400PR-10" %}
Most of the **OP8110-3 amplifier** control and monitoring topics have been covered in the **Common features** tab.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FuAqqhxB2kELecniLBwAk%2Fimage.png?alt=media&amp;token=f4e35d52-2987-40ee-a729-901aea3103b2" alt=""><figcaption></figcaption></figure>

### Monitor the OP8110-3 amplifier (OP1400PR-10)

* Underneath the **DC Bus On/Off button** the **DC bus voltage** is displayed.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Frr8FzfLiAuq8N44z9xL8%2Fimage.png?alt=media&amp;token=d9a71948-20e4-4742-b224-ae7fd3d8fecf" alt="" width="189"><figcaption></figcaption></figure>

* **Voltage (RMS)**: Display **RMS voltages** of the **amplifier outputs**.
* **Current (RMS)**:  Display **RMS currents** of the **amplifier outputs**.
  * **RMS** is calculated with the **internal reference frequency**.
  * **No values** are shown for **DC Mode**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FtNkKXk5QaJwAviS7vbHx%2Fimage.png?alt=media&amp;token=544a17f8-9170-4886-9c50-d0c26ee4728b" alt="" width="189"><figcaption></figcaption></figure>

* **Voltage graph** : Displays the **output voltage**.
* **Current graph**: Displays the **output current**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FHX6Ubemo6snoDqKlI6EX%2Fimage.png?alt=media&amp;token=e805fa53-47ba-4e4a-945c-d0c97cf329dd" alt="" width="375"><figcaption></figcaption></figure>

### Set the eHS controlled source reference

* The eHS-controlled source reference is used with the provided example/production model.
* When the user selects **eHS** as the **reference source**, the **corresponding signals mapped to each leg** in the **Schematic Editor** serve as **references** for the respective amplifier outputs.
* In the example model, three-phase sinusoidal signals with a controllable magnitude are generated in the CPU and fed into the **Schematic Editor** to provide these reference signals.
* The **Mag (Peak)** parameter, when used with the **eHS-controlled source reference**, controls the magnitude of the eHS reference signals.
* The value is expressed in volts (V) or amperes (A).&#x20;
* Enter a peak value or use the up and down arrows.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FMplcuPruZLLuI8no0A6l%2Fimage.png?alt=media&amp;token=5fd2408c-0b03-4439-8d16-4d54b992fba8" alt="" width="208"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-20" %}
Most of the **OP8110-6 amplifier** control and monitoring topics have been covered in the **Common features** tab.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FBojxWv15bNwrRvGlSvFB%2Fimage.png?alt=media&amp;token=cf25cdb7-e4b0-41f3-8d1c-1385746f2cb2" alt=""><figcaption></figcaption></figure>

### Monitor the OP8110-6 amplifier (OP1400PR-20)

* Underneath the **DC Bus On/Off buttons** the **DC bus voltage** is displayed for **Group 1** (Gr1) and **Group 2** (Gr2).

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FOIc1v2DTSennRUeGl19n%2Fimage.png?alt=media&amp;token=85e065d4-10c2-4c33-a889-00f34c6e1f56" alt="" width="375"><figcaption></figcaption></figure>

* **Voltage (RMS)**: Display **RMS voltages** of the **amplifier outputs**.
* **Current (RMS)**:  Display **RMS currents** of the **amplifier outputs**.
  * **RMS** is calculated with the **internal reference frequency**.
  * **No values** are shown for **DC Mode**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FGrPorNXdy6utyUo83tX7%2Fimage.png?alt=media&amp;token=5e95cfc7-f540-4754-a3a7-b8fa79eda996" alt="" width="298"><figcaption></figcaption></figure>

### Set the eHS controlled source reference

* The eHS-controlled source reference is used with the provided example/production model.
* When the user selects **eHS** as the **reference source**, the **corresponding signals mapped to each leg** in the **Schematic Editor** serve as **references** for the respective amplifier outputs.
* In the example model, three-phase sinusoidal signals with a controllable magnitude are generated in the CPU and fed into the **Schematic Editor** to provide these reference signals.
* The **Mag (Peak)** parameter, when used with the **eHS-controlled source reference**, controls the magnitude of the eHS reference signals.
* The value is expressed in volts (V) or amperes (A).&#x20;
* Enter a peak value or use the up and down arrows.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F3DmYW2BUWeUylHjg8IqM%2Fimage.png?alt=media&amp;token=7327dfde-0343-475b-88c0-aac78c14cb95" alt="" width="294"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-30" %}
All the **OP8110-6** and **OP8110-3 amplifiers** control and monitoring topics have been covered in the **Common features** tab.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FTijkaO5DPGrvJc15mGEO%2Fimage.png?alt=media&amp;token=14587afc-9eff-42c0-a864-bde07a8e4955" alt=""><figcaption></figcaption></figure>

### Monitor the OP8110-3 and OP8110-6 amplifiers (OP1400PR-30)

* **Voltage (RMS)**: Display **RMS voltages** of all the **amplifier outputs**.
* **Current (RMS)**:  Display **RMS currents** of all the **amplifier outputs**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FuubFwoJsIk4SXuAfor3O%2Fimage.png?alt=media&amp;token=43f5cf79-742c-46d4-829f-0a5909fcd575" alt="" width="318"><figcaption></figcaption></figure>
{% endtab %}

{% tab title="OP1400PR-60" %}
All of the **OP8110-6 amplifiers** control and monitoring topics have been covered in the **Common features** tab.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FGuRnWwmfe3N4AJTAD7G5%2Fimage.png?alt=media&amp;token=a01a8b55-c722-4112-aa6b-d387f2b0506b" alt=""><figcaption></figcaption></figure>
{% endtab %}
{% endtabs %}

## Analog tab <a href="#analog-tab" id="analog-tab"></a>

### Overview

The analog tab allows the user to **control** the **analog references** (magnitude (RMS), frequency, and phase) and **view** the **reference analog input** in a **graph**.

{% hint style="info" %}
The Analog tabs for all OP1400PR models are similar and are not reproduced here. The **OP1400PR-60 Analog tab is used for illustration**.
{% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FNgn5Dj78dS0j8gYOdoL7%2Fimage.png?alt=media&amp;token=17e5c169-e64e-4b2b-a65d-42b8b7d6a597" alt=""><figcaption><p>OP1400PR-60 Analog panel</p></figcaption></figure>

Your system includes an **example model** or a **production model** on the **USB key** accompanying its system. The models can be found in the “**test\_model**” **folder** of the USB key.

{% hint style="info" %}
Please, read carefully the **Signal Mapping** and **Note** sections as they provide important information.

<img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FeIM43s3aDjXZst8trcS9%2Fimage.png?alt=media&amp;token=9cdecee6-13e4-479e-9a42-d6ed4122b0e5" alt="" data-size="original">
{% endhint %}

With the example model, a **three-phase sine wave** is output with the **analog-out**, and a **loopback cable** is used to **feed the sine wave generated back to the model** using **Analog IN**.

If the user selects **Analog IN** as the [**reference source**](#change-the-group-reference-source), then the **scaled signals** from the **respective channels** **mapped** (see the **Signal Mapping list** in the [**Analog tab**](#analog-tab)) are the **references for the respective amplifier outputs**.

### Monitor the reference signals

These scopes show the **signals received from the Analog IN** **channels** of the simulator.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FYxu8lIKVg9ma2NcsNSYz%2Fimage.png?alt=media&amp;token=38a69425-452c-400b-8d95-ac088af53869" alt="" width="375"><figcaption></figcaption></figure>

### Change the analog references: magnitude, frequency or phase

**Analog Reference**: Change the **magnitude** \[Mag (RMS)], the **frequency** and the phase by **typing a value** or by using the **up and down arrow keys**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F3gihbZhQYavNVfluiKiT%2Fimage.png?alt=media&amp;token=aeea5b88-ef8d-4b96-8750-d26648765139" alt="" width="195"><figcaption></figcaption></figure>

## FW\_Features tab <a href="#fw_features-tab" id="fw_features-tab"></a>

### Overview <a href="#firmware-features-overview" id="firmware-features-overview"></a>

This tab accesses the **firmware features** (**FW\_Features)** panel of an **OP1400PR**.

{% hint style="info" %}
The FW\_Features tabs for all OP1400PR models are similar and are not reproduced here. The **OP1400PR-60 FW\_Features tab is used for illustration**.
{% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FDxChS6uNYYAI012CAq1F%2Fimage.png?alt=media&amp;token=a8ae9dfe-b096-4748-b9cb-cb8da1cbbbf7" alt=""><figcaption><p>OP1400PR-60 firmware feature panel</p></figcaption></figure>

This panel allows the user to **enable** or **disable** on-the-fly **firmware features** like **harmonics** and **CPU resolution improvement**.

It allows the user to **configure** the **harmonics injected** to the **respective groups** and it also allows the user to set **a bias** for the **reference signals sent to the amplifier** regardless of the reference source.

### Enable or disable the harmonics feature

Click the **Harmonics** **button** to **enable** or **disable** the [**harmonic injection**](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md#harmonic-injection).

<div data-with-frame="true"><figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FY5OWlZrMB7YUPzifucpC%2Fimage.png?alt=media&amp;token=0af2a5be-7b7e-4227-a9d1-464ca7e49f11" alt="" width="375"><figcaption></figcaption></figure></div>

When **enabled**, the user **can individually set the harmonic parameters** for **each line** of **each group** of **each amplifier**.

### Configure harmonic injection parameters

In the **example** below **each OP8110-6 column** represents **one 4Q amplifier** on an **OP1400PR-60** test bench.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FhzjP5ctQidP5sUOI8eCd%2Fimage.png?alt=media&amp;token=060c9530-71c9-4463-97b4-829d1db4254d" alt=""><figcaption></figcaption></figure>

For **each amplifier**, the columns are divided into **groups**:

* **OP8110-3**
  * **Group 1** (L1, L2, L3)
* **OP8110-6**
  * **Group 1** (L1, L2, L3)
  * **Group 2** (L4, L5, L6)

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FZIaouNlLACNXp6mZz5qY%2Fimage.png?alt=media&amp;token=43f92e16-8060-4eff-9085-41fccc84de86" alt="" width="563"><figcaption></figcaption></figure>

**Each group** has **6 harmonic parameters** identified as **H1 to H6**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FBRwfyaiOu5FycAaTqfs5%2Fimage.png?alt=media&amp;token=4a94999c-c15c-4554-8059-ade253e111a4" alt="" width="393"><figcaption></figcaption></figure>

Each **harmonic parameter** can be set as described below.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FhTyQJWUt6V6VGDSOMb04%2Fimage.png?alt=media&amp;token=97878248-c971-4ae9-8f05-d17598eb6ac1" alt="" width="476"><figcaption></figcaption></figure>

* **Magnitude**: Enter a value or use the up and down arrow keys to **set the magnitude** of the **respective harmonic component** (H1 to H6).
* **Frequency**: Enter a value or use the up and down arrow keys to **set the harmonic frequency** of the **respective harmonic component** (H1 to H6).
* **Ph-Diff**: Click the latching button to **change the phase difference** between the three components in the harmonic group. The two possible states are:
  * **3ph**: The **phase difference** between the three components in the harmonic group is **set to 120 degrees**.
  * **zero**: The **phase difference** between the three components in the harmonic group is set to **zero**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F6USZqZJ3v6MFxUvzQyBc%2Fimage.png?alt=media&amp;token=208265b7-d945-4bba-9fdb-7b6d66ed50f6" alt="" width="180"><figcaption></figcaption></figure>

* **Reset**: Push this **non-latching button** to **reset the phase of the harmonics on the fly**.

**CPU Resolution Improvement**: click the latching button to **enable** or **disable** the [**CPU resolution improvement feature**](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md#enable-cpu-reference-signal-resolution).

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FmixSXe5BTktsYv0ALzQ3%2Fimage.png?alt=media&amp;token=ea2f7a32-43f5-480c-b45c-385cb0098ca8" alt="" width="292"><figcaption></figcaption></figure>

**Bias**: Fields to **add a bias** to the **respective output references**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fd8e1xmmhUiTPBCGP8uuD%2Fimage.png?alt=media&amp;token=02686991-be69-4226-9bc4-f94fb00027fd" alt="" width="289"><figcaption></figcaption></figure>

## Offset tab <a href="#measurement-offsets" id="measurement-offsets"></a>

### Overview

This tab provides fields to **set offsets** in the amplifier measurements for all the amplifiers present in the test bench, **before these are sent to eHS**. Values use the corresponding unit of measurement, i.e. **volts (V)** or **amperes (A)**.

* ​**Vout**: Output voltage measurement offsets for [amplifier outputs L1 to L6](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier/hardware-interface.md#outputs).
* ​**Iout**: Output current measurement offsets for [amplifier outputs L1 to L6](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier/hardware-interface.md#outputs).
* ​**Vfem**: Voltage measurement offsets for [remote sense connectors SENSE 1-SENSE 6](https://www.opal-rt.com/docs/op1400pr/op1400pr-overview/description-and-components/op8110-4q-power-amplifier/hardware-interface.md#remote-sense-connectors).

{% hint style="info" %}
The Offset tabs for all OP1400PR models are similar and are not reproduced here. The **OP1400PR-60 Offset tab is used for illustration**.
{% endhint %}

### Set the amplifier's measurement offsets

In the desired field, enter an offset value or use the up and down arrows to set the offset value.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fs18DCxThAXRXjZzBUeKP%2Fimage.png?alt=media&amp;token=ab7d1f56-2d43-42fe-bd6e-99e56380258e" alt=""><figcaption><p>OP1400PR-60 offset panel</p></figcaption></figure>

## A2eHS\_Gain tab <a href="#amplifier-to-ehs-gain" id="amplifier-to-ehs-gain"></a>

### Overview

This **Amplifier to eHS Gain tab** provides the fields to **scale the measurements and references from the amplifier which are fed to the eHS** and also the **gain/scale of two parallel current measurement configurations** (**Ipc**).​

{% hint style="info" %}
The A2eHS\_Gain tabs for all OP1400PR models are similar and are not reproduced here. The **OP1400PR-60 A2eHS\_Gain tab is used for illustration**.
{% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F0lG9rFTL25rIwE6fK7eQ%2Fimage.png?alt=media&amp;token=4d849e97-4f78-4c17-a5f2-5cbbd8e576a7" alt=""><figcaption><p>OP1400PR-60 Amplifier to eHS gain panel</p></figcaption></figure>

#### Amplifiers

There is a **block of gain parameters for each amplifier** present in the OP1400PR model and **for each amplifier** output; L1 to L3 or L1 to L6, depending on the amplifier model.

* **Vout**: Output-voltage measurement gain. Voltage measured at OP8110 outputs L1 to L6
* **Iout**: Output-current measurement gain. Current measured at OP8110 outputs L1 to L6
* **Vfem**: Remote-sense voltage measurement gain. Voltage measured through SENSE 1 to SENSE 6
* **Vref**: Reference-signal gain sent by the model. The reference is associated with the OP8110 outputs

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FHny5PfdSEvucJ7UwR954%2Fimage.png?alt=media&amp;token=0ee61cba-e8c3-4afa-abbd-99481d7779f5" alt="" width="375"><figcaption></figcaption></figure>

#### **Parallel configuration**

* **PC1\_Ipc**: Gain/scaling for parallel configuration 1 current measurement
* **PC2\_Ipc**: Gain/scaling for parallel configuration 2 current measurement

They are the current measurements for the parallel configurations set in the OP1400PR UI present in the real-time simulation model.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F4UAz11fgkes790TUrIVB%2Fimage.png?alt=media&amp;token=7635ff20-bbef-45e8-af01-eeb1b7b0af51" alt="" width="213"><figcaption></figcaption></figure>

### Set the amplifier's gain to eHS

In the desired field, enter a **gain value** or use the up and down arrows to set the gain value.\
Gain values are a **multiplier of the signal value**. For example:

* **Vout gain = 1**: a 100 V measurement is passed without additional scaling, i.e. 100 V
* **Vout gain = 0.5**: the corresponding signal delivered to eHS is scaled by 0.5, i.e. 50 V
* **Vout gain = 2**: it is scaled by 2, i.e. 200 V

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F1MbxxR7WxCQp8B2lRBUQ%2Fimage.png?alt=media&amp;token=061c4bfc-464a-43c2-8042-d9189e93c44c" alt="" width="370"><figcaption></figcaption></figure>

### Set the parallel configuration gain to eHS

​In the desired field, enter a **gain value** or use the up and down arrows to set the gain value. Gain values are a **multiplier of the signal value**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FMSTSOqX7B0asXIKWe0CP%2Fimage.png?alt=media&amp;token=eaba18b5-3cca-49eb-9db9-7ddb891d680b" alt="" width="213"><figcaption></figcaption></figure>

## eHs2A\_Gain tab <a href="#ehs-to-amplifier-gain" id="ehs-to-amplifier-gain"></a>

### Overview

This tab provides fields to **scale the references sent from the eHS to the amplifier**.

{% hint style="info" %}
The eHS2A\_Gain tabs for all OP1400PR models are similar and are not reproduced here. The **OP1400PR-60 eHS2A\_Gain tab is used for illustration**.
{% endhint %}

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FoS3kHXF4XeeTpoQBptfJ%2Fimage.png?alt=media&amp;token=a4530fa1-dee6-406c-80df-93946b65db12" alt=""><figcaption><p>OP1400PR-60 eHS to amplifier gain panel</p></figcaption></figure>

### Set the Vref gain from eHS to the amplifiers

In the desired field, enter a **gain value** or use the up and down arrows to set the gain value.\
Gain values are a **multiplier of the signal value**.

## Debug tab <a href="#debug" id="debug"></a>

### Overview

This tab provides the **fault codes** for **each output** and **global fault**.

{% hint style="info" %}
The Debug tabs for all OP1400PR models are similar and are not reproduced here. The **OP1400PR-60 Debug tab is used for illustration**.
{% endhint %}

Whenever there is a **fault** seen in the [**MasterCtrl tab**](#masterctrl-tab), users can see the **fault code related to it** here in this tab.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FTYfYB8NFRf8Vn9MS3GBr%2Fimage.png?alt=media&amp;token=660948c6-078f-4b79-af17-4d8b157a5525" alt=""><figcaption></figcaption></figure>

## LP-HP Ctl\&M menu

### Overview

The **LP and HP bus bar** control and monitoring (Ctl\&M) panel allows users to **control the DUT connections** to the selected **Smart Bus Bar** and **monitor the electrical measurements** at those connections.

**LP bus bar** supports **3 devices under test (DUTs)**, whereas the **HP bus bar** supports **2 DUTs**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FTGNLWdd8fKMqaNpqcx9g%2Fimage.png?alt=media&amp;token=f31d0a45-a326-4490-9d20-14f29481aa61" alt=""><figcaption></figcaption></figure>

### Enable or disable MODBUS and digital inputs (DI)

* **Select** the **bus bar type**: None, **LP Bus Bar** and **HP Bus Bar** depending on what is installed on your test bench.
* **MODBUS**: When **turned on**, it allows the **corresponding DUT contactor** to be **controlled through MODBUS**.
  * If MODBUS is enabled, the round indicator (left of the toggle switch) turns on.
* **DI**: When **turned on**, it allows the **corresponding DUT contactor** to be controlled through a **digital input (DI)**.
  * **Only one control mode**, MODBUS or digital inputs (DI), **can be enabled**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2Fp6DjCOkbLo4ECGd1WIDL%2Fimage.png?alt=media&amp;token=3b4e3b83-66af-4e84-b035-3e0c48a8d7a5" alt="" width="297"><figcaption></figcaption></figure>

The **circular indicators** next to **DUT-01**, **DUT-02**, and **DUT-03** provide the **status of the corresponding DUT connection**.

Conceptually: **Control command** → **MODBUS or DI** → **DUT contactor** → **DUT connected/disconnected from the bus bar**

These controls are related to the **bus bar contactors**, not directly to turning the OP8110 amplifier outputs on and off.

### Monitor a device under test (DUT) measurements

* **Select** the **bus bar type to monitor**.&#x20;

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FXEwCPbZ5yEhaBmZsan1E%2Fimage.png?alt=media&amp;token=4522db0f-d7a4-4966-a200-233097e7b551" alt="" width="445"><figcaption></figcaption></figure>

* The **bus bar voltage** and **DUT voltage and current** will show on the **graphs**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F5oyBlxFVSQeDYFCuOHRX%2Fimage.png?alt=media&amp;token=f7627023-6f6d-461b-8d4a-d07fff14781e" alt="" width="563"><figcaption></figcaption></figure>

## LP-HP Config menu

### Overview

The OP1400PR allows [two electrical configurations](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md#predefined-configuration-selection) to be predefined in the  [OP1400PR-nn UI block](https://www.opal-rt.com/docs/op1400pr/supplementary-operations/op1400pr-nn-ui-block.md). This panel allows the user to control and monitor each configuration.

The two columns, **CONFIG-1** and **CONFIG-2**, represent the two configurations that **can be used simultaneously** within the limits defined by the OP1400PR interface.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F7FpDH7bcSEAym55SqWqd%2Fimage.png?alt=media&amp;token=6b587c64-5ddb-4546-b5e5-d021916f26c8" alt=""><figcaption></figcaption></figure>

### Control the configurations

* **DC Bus**: **Turns on or off** the amplifier's **DC bus precharge**.
  * The **round indicator** next to the button shows the **actual status**.
  * When the **DC precharge is successfully completed**, the **indicator** turns **green**.
  * When **DC bus** is **ON**, then **DC bus** is **precharged** and **amplifier outputs can then be enabled**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FGJrRbLWaVoZWtlqZ3lR0%2Fimage.png?alt=media&amp;token=85369d44-eab7-41d3-b605-f92d9c123de9" alt="" width="563"><figcaption></figcaption></figure>

* **Configuration**: This field **indicates** the **predefined configuration assigned** to **CONFIG-1** or **CONFIG-2**.
  * The **configurations** themselves are **predefined** in the **OP1400PR-nn UI block**.
  * The possible values are: **None**, **Independent** and **Differential**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FNCxE7kfk90JFyTa2NEpk%2Fimage.png?alt=media&amp;token=50e13a5b-c532-49ba-acfa-ce75931962b9" alt="" width="563"><figcaption></figcaption></figure>

* **Phase-1**, **Phase-2**, and **Phase-3**: These buttons control the individual amplifier outputs.
  * **When a phase is enabled**, the **associated amplifier output begins switching and produces the requested output**. The adjacent **status indicator** shows the **actual switching status**.
  * The behavior depends on the selected configuration:
    * In **independent mode**, the user controls **Phase-1, Phase-2, and Phase-3**.
    * In a **differential configuration**, the user controls **Phase-1 and Phase-2**, while **Phase-3 becomes inactive**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FYWDK4OtoOiJZXEkEGiPS%2Fimage.png?alt=media&amp;token=0c8036ea-bc21-4f70-9f0c-bb41413d3c98" alt="" width="433"><figcaption></figcaption></figure>

* **Internal Reference**: This section defines the **reference signal** **generated internally** by the system.
  * **Mag (RMS)** specifies the **RMS magnitude** of the **reference signal.**
    * When the group operates in **Voltage mode**, the **magnitude** is expressed in **V**.
    * When it operates in **Current mode**, the unit changes to **A**.
  * **Frequency** specifies its frequency in hertz.
  * For example, an internal reference set to **120 V RMS / 60 Hz** would request a 120 V RMS, 60 Hz reference signal from the amplifier, subject to the selected configuration and enabled outputs.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FgQRXMJNOFpltskZyOXw9%2Fimage.png?alt=media&amp;token=17d6b827-587d-456c-9dc5-0f7e6e8b7568" alt="" width="291"><figcaption></figcaption></figure>

* **External Reference**: This section displays the characteristics of a reference coming from an **external source**, rather than one generated internally.
  * For example, when **Analog IN** is selected as the reference source, appropriately mapped analog input channels can provide the reference signals for the amplifier outputs.
  * Bring the **reference magnitude back to zero before changing the reference source**, rather than switching sources while a non-zero voltage or current reference is being applied.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FXRqaOo7QV09fgz63lyFr%2Fimage.png?alt=media&amp;token=23007d79-6d65-45fb-8a9b-0bcf9295f191" alt="" width="182"><figcaption></figcaption></figure>

### Monitor the configurations

Each configuration has **two monitoring graphs**:

* **Voltage** \[V]
* **Current** \[A]

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FnAF0e4kW14GoQGeamjqI%2Fimage.png?alt=media&amp;token=109693b3-d456-424a-956a-76fbcc89723f" alt="" width="560"><figcaption></figcaption></figure>

## OP8110-6 menu

### Overview

{% hint style="info" %}
This menu is only present for the OP1400PR-60 test bench. For the other test benches, the global monitoring is done in the [**Master Panel tabs**](#masterctrl-tab) in the [**Main Panel menu**](#main-panel-menu).
{% endhint %}

This is a **global monitoring panel** for the **three OP8110-6 amplifiers** installed in the **OP1400PR-60** Prime HIL test bench.

For individual and detailed monitoring of each amplifier, refer to the[ **#n OP8110-3 and OP8110-6 menu**](#n-op8110-3-and-op8110-6-menu) below.

### Monitor the measurements of an OP8110-6 amplifier

* **Rows L1 to L6** correspond to the six outputs of each OP8110-6 amplifier.
* Each amplifier has two measurements for each output:
  * **Voltage \[V]**
  * **Current \[A]**

The panel is for RMS alternating current monitoring only. The RMS measurements are based on the frequency set in the [**Main Panel**](#main-panel-menu).

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FrVgoiiMfVIfz9yUw8qW7%2Fimage.png?alt=media&amp;token=d56de377-970d-4abf-b5ab-36e78978e286" alt=""><figcaption></figcaption></figure>

## #n OP8110-3 and OP8110-6 menu

### Overview

These panels are used to **monitor the status** of the **respective amplifiers** and **measurements**. The amplifier model can be an **OP8110-3** or **OP8110-6**.

A menu appears for **each installed amplifier on the test bench**, i.e., one, two, or three.

{% hint style="info" %}
For illustration we will use the panel **#1 OP8110-6** (two groups) from an **OP1400PR-60** test bench (three amplifiers).
{% endhint %}

This monitoring panel shows the amplifier’s DC bus status, faults, RMS measurements, and waveforms for its six outputs.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FnxRIlkwJaiuSiKZHsRc2%2Fimage.png?alt=media&amp;token=e40823f8-c895-42d4-88b6-388f3d2b3ae6" alt=""><figcaption></figcaption></figure>

### Monitoring an OP8110-6 amplifier

* **Vdc\_G1** and **Vdc\_G2**: These indicate the **DC bus voltage associated** with **Group 1** and **Group 2**.
* **Fault Status**:
  * The six **circular fault indicators** correspond to L1 | L2 | L3 | L4 | L5 | L6.
  * The **square fault indicator in the middle** indicates a **global amplifier fault**.
  * **Faults** associated with outputs can be **investigated** in the [**Debug**](#debug) tab.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2F7FmLYZCtyB0re8LLkpTJ%2Fimage.png?alt=media&amp;token=3dbb61c4-bb23-4218-a852-e31e1aa6ca54" alt="" width="326"><figcaption></figcaption></figure>

* **Voltage and current measurements**: Display **RMS voltages** and **RMS currents** for **all amplifier outputs**.
  * The **RMS calculation** uses the **frequency configured** in the [**Main Panel**](#main-panel-menu).

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FgKvnRgb777U5rBhctHBB%2Fimage.png?alt=media&amp;token=e170334c-b927-44c9-abe2-adc61a115509" alt="" width="320"><figcaption></figcaption></figure>

* **Group 1** and **Group 2**:  The right-hand area separates the **six outputs** into their **two amplifier groups**.
  * **Group 1**: L1, L2, and L3
  * **Group 2**: L4, L5, and L6
  * **Mode**: The mode can be **independent,** where each output in the group behaves as an independent amplifier output or **differential** where two amplifier outputs work together.
  * **Current type**: the values can be **AC** or **DC**.
  * **Voltage graphs**: Display the **AC or DC output voltage**.
  * **Current graphs**: Display the **AC or DC output current**.

<figure><img src="https://3155739458-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVJdfp93TWLISP6nkqTs%2Fuploads%2FJ8kTiuF0PV44AuISrFVq%2Fimage.png?alt=media&amp;token=5096ed9b-5ace-4998-996d-4ad4d39676fb" alt=""><figcaption></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op1400pr/operate-the-test-bench/control-and-monitor-the-test-bench.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.