> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op4512/certifications-and-standards/directive-requirements.md).

# Directive Requirements

The essential requirements of the directive 2014/30/EU are covered by the following harmonized standards **EN61326-1 (2021)** - Electrical equipment for measurement, control and laboratory use.

The immunity test requirements used for this Product qualification are for equipment intended for an industrial electromagnetic environment.

<table data-full-width="false" data-search="false"><thead><tr><th width="212.8182373046875" valign="top">Standard &#x26; Certifying Body</th><th width="533.599853515625" valign="top">Title &#x26; Scope | Performance Criterion (if applicable)</th></tr></thead><tbody><tr><td valign="top"><p>FCC part 15 (2022), subpart B</p><p><br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2Fr09XLwRkXM1zsGcQvXzo%2Fimage.png?alt=media&amp;token=f9b80754-4a15-494d-b440-7d03692391ad" alt="" data-size="line"></p></td><td valign="top">Conducted Emissions<br>Class A 150 kHz-30MHz</td></tr><tr><td valign="top">FCC part 15 (2022), subpart B<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2Fr09XLwRkXM1zsGcQvXzo%2Fimage.png?alt=media&amp;token=f9b80754-4a15-494d-b440-7d03692391ad" alt="" data-size="line"></td><td valign="top">Radiated Emissions<br>Class A 30 MHz-21GHz</td></tr><tr><td valign="top">ICES-001 Issue 5 (2020)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FGhRxJc9TUSC0UPr9B74s%2Fimage.png?alt=media&amp;token=b53f79a3-9919-428e-908b-9c3511388cfc" alt="" data-size="line"></td><td valign="top">Radiated Emissions CSA CISPR 11:19<br>Group 1 - class A<br>30 MHz-1GHz</td></tr><tr><td valign="top">ICES-001 Issue 5 (2020)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FGhRxJc9TUSC0UPr9B74s%2Fimage.png?alt=media&amp;token=b53f79a3-9919-428e-908b-9c3511388cfc" alt="" data-size="line"></td><td valign="top">Conducted Emissions CSA CISPR 11:19<br>Group 1 - class A<br>150 kHz-30MHz</td></tr><tr><td valign="top">IEC61000-4-2 (2008)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"><br></td><td valign="top">Electrostatic Discharge Immunity | Performance Criteria B<br>Contact: ±4 KV Air: ±2kV, ±4kV, ±8 KV</td></tr><tr><td valign="top">IEC61000-4-3 (2020)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"><br></td><td valign="top">Radiated Electromagnetic Field Immunity | Performance Criteria A<br>80 MHz-1000MHz: 10 V/m<br>1.4 GHz-6 GHz: 3 V/m</td></tr><tr><td valign="top">IEC61000-4-4 (2012)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"></td><td valign="top">Electrical Fast Transient Immunity | Performance Criteria B<br>Power: ±2 KV, 5 kHz &#x26; 100 kHz<br>I/ O Ports: ±1 KV, 5 kHz &#x26; 100 kHz<br>Communication Ports: ±2 KV, 5 kHz &#x26; 100 kHz</td></tr><tr><td valign="top">IEC61000-4-5 (2014) A1 (2017)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"><br></td><td valign="top">Surge Immunity | Performance Criteria B<br>Power: ±2 KV L-PE, ±1 KV L-L<br>I/O Ports: N/A<br>Communication Ports: N/A</td></tr><tr><td valign="top">IEC61000-4-6 (2013)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"></td><td valign="top">Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields | Performance Criteria A<br>Power: 3 V<br>I/O Ports: 3 V<br>Communication Ports: 3 V</td></tr><tr><td valign="top">IEC61000-4-8 (2009)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"></td><td valign="top">Power Frequency Magnetic Field Immunity | Performance Criteria A<br>Continuous Field: 30A/m, 50 Hz &#x26; 60 Hz</td></tr><tr><td valign="top">IEC61000-4-11 (2020)<br><img src="https://4286127377-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgT2kDoXVJn89T4Y7NiYB%2Fuploads%2FP0DqwgsPLxRQxa0FUGJ8%2Fimage.png?alt=media&amp;token=eb422911-b170-4bb1-95f6-5571a607d8d7" alt="" data-size="line"></td><td valign="top"><p>Voltage Dips, Short Interruptions and Voltage Variation Immunity on AC Input<br>Voltage dips:<br>0%Un during 1 cycle | Performance Criteria B<br>40%Un during 10 cycles (at 50 Hz) | Performance Criteria C<br>40%Un during 12 cycles (at 60 Hz) | Performance Criteria C<br>70%Un during 25 cycles (at 50 Hz) | Performance Criteria C<br>70%Un during 30 cycles (at 60 Hz) | Performance Criteria C</p><p>Short interruptions:<br>0%Un during 250 cycles (at 50 Hz) | Performance Criteria C<br>0%Un during 300 cycles (at 60 Hz) | Performance Criteria C</p></td></tr><tr><td valign="top"><p>IEC61010-1:2010,</p><p>IEC 61010-1:2010/AMD1:2016<br><img src="https://content.gitbook.com/content/gT2kDoXVJn89T4Y7NiYB/blobs/uaL5uQZrRnYn72XemCvG/image.png" alt="" data-size="line"></p></td><td valign="top">Single fault condition - 4.4.1<br>Protective Conductor Abnormal - 4.4.2.3<br>Cooling Abnormal - 4.4.2.10<br>Input - 5.1.3 c<br>Durability Of Markings - 5.3<br>Applied Force - 6.2.2<br>Permissible Limits For Accessible Parts - 6.3<br>Impedance Of Protective Bonding Test - 6.5.2.4<br>Dielectric Voltage Withstand - 6.8<br>Humidity Conditioning - 6.8.2<br>Capacitor Discharge - 6.10.3<br>Stability 10 Deg - 7.4<br>Handle Strength Test - 7.5.2<br>Rack Mounting Test - 7.6<br>Static Rigidity - 8.2.1<br>Impact Test - 8.2.2<br>Drop Test (Non-Hand Held Equipment) - 8.3.1<br>Temperature - 10.1</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op4512/certifications-and-standards/directive-requirements.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.