> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op5020xg2/certifications-and-standards/declaration-of-conformity-ukca-ce.md).

# Declaration of Conformity UKCA CE

## Declaration of conformity UKCA CE for the OP5020XG2 <a href="#declaration-of-conformity-ukca-ce-for-the-op4610xg-and-the-op4610-io" id="declaration-of-conformity-ukca-ce-for-the-op4610xg-and-the-op4610-io"></a>

Manufacturer Name/Address:

**OPAL‑RT TECHNOLOGIES INC.**\
1751 Richardson suite 1060\
Montreal QC H3K 1G6 Canada\
[**www.opal-rt.com**](https://www.opal-rt.com/)

This declaration of conformity is issued under the sole responsibility of: **OPAL‑RT TECHNOLOGIES INC.**

### Product model <a href="#product-model-product" id="product-model-product"></a>

**OP5020XG** with any of the following options:

* OP3411 (CAN kit)
* OP5455 (Copper PCIe kit)
* I350T4V2BLK (Ethernet)

### Product description <a href="#product-description" id="product-description"></a>

Simulator with optional communication cards intended for indoor use only.\
Ratings: 100-240 VAC, 50-60 Hz, 400 W max, pollution degree 2

### Product category <a href="#product-category" id="product-category"></a>

Electrical equipment for measurement, control, and laboratory use.

### CE conformity with the relevant community harmonization legislation <a href="#ce-conformity-with-the-relevant-community-harmonization-legislation" id="ce-conformity-with-the-relevant-community-harmonization-legislation"></a>

* 2014/30/EU – Electromagnetic Compatibility Directive
* 2014/35/EU – Low Voltage Directive
* 2011/65/EU & (EU) 2015/863 – Restriction of Hazardous Substances (RoHS) in Electrical and Electronic Equipment directive
* 2012/19/EU – Waste from Electrical and Electronic Equipment (WEEE) Directive
* This product is compliant with Regulation (EC) No 1907/2006 (REACH). It contains one or more substances of very high concern (SVHC) above 0.1% w/w, and all obligations under Article 33(1) have been fulfilled, including notification to the ECHA SCIP database <https://echa.europa.eu/fr/scip-database>

### UKCA conformity with the relevant harmonization legislation <a href="#ukca-conformity-with-the-relevant-harmonization-legislation" id="ukca-conformity-with-the-relevant-harmonization-legislation"></a>

* Electromagnetic Compatibility Regulations 2016
* Electrical Equipment (Safety) Regulations 2016
* The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

### References to the standards in relation to which conformity is declared

<table data-search="false"><thead><tr><th width="112.18179321289062" valign="top">Category</th><th width="356.27276611328125" valign="top">Standards</th><th valign="top">Test Specifications</th></tr></thead><tbody><tr><td valign="top"><strong>Emissions</strong></td><td valign="top">EN IEC 61326-1:2021</td><td valign="top"></td></tr><tr><td valign="top"><strong>Emissions</strong></td><td valign="top">EN55011 (2016) A1(2017)<br>CISPR11 (2015) A1(2016) A2 (2019)</td><td valign="top">Conducted Emissions: Group 1 - class A 150 kHz-30 MHz<br>Radiated Emissions: Group 1 - class A 30 MHz-1 GHz, 1 GHz-20 GHz</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-2 (2008)</td><td valign="top">Contact: ±4 kV Air: ±2 kV, ±4 kV, ±8 kV</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-3 (2020)</td><td valign="top">80 MHz-1,000 MHz: 10 V/m<br>1.4 GHz-6 GHz: 3 V/m</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-4 (2012)</td><td valign="top">Power: ±2 kV / 5 kHz &#x26; 100 kHz<br>I/O Ports: N/A<br>I/O Ports connected to power: ±1 kV / 5 kHz &#x26; 100 kHz</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-5 (2014) A1(2017)</td><td valign="top">Power: ±2 kV L-PE / ±1 kV L-L<br>I/O Ports: N/A<br>Communication Ports: N/A</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-6 (2013)</td><td valign="top">Power: 3 V<br>I/O Ports: N/A<br>Communication Ports (Ethernet): 3 V</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-8 (2009)</td><td valign="top">Continuous Field: 30 A/m - 50 Hz &#x26; 60 Hz</td></tr><tr><td valign="top"><strong>Immunity</strong></td><td valign="top">IEC61000-4-11 (2020)</td><td valign="top"><p>Voltage dips:</p><p>0% Un during 1 cycle<br>40% Un during 10 cycles (at 50 Hz)<br>40% Un during 12 cycles (at 60 Hz)<br>70% Un during 25 cycles (at 50Hz)<br>70% Un during 30 cycles (at 60 Hz)</p><p>Short interruptions:<br>0% Un during 250 cycles (at 50 Hz)<br>0% Un during 300 cycles (at 60 Hz)<br><br>Short interruptions:<br>0% Un during 250 cycles (at 50 Hz)<br>0% Un during 300 cycles (at 60 Hz)</p></td></tr><tr><td valign="top"><strong>Safety</strong></td><td valign="top">EN 61010-1:21010/A1:2019<br>IEC 61010-1:2010, IEC 61010-1:2010/AMD1:2016</td><td valign="top"></td></tr></tbody></table>

<div align="left"><figure><img src="https://1076585587-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FoFy31JPo94xIV8nCRsjv%2Fuploads%2FbPxYxjCtStll8wT3tekk%2Fimage.png?alt=media&amp;token=77671d36-3b1e-48c0-ba5e-a43868d13330" alt=""><figcaption></figcaption></figure></div>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op5020xg2/certifications-and-standards/declaration-of-conformity-ukca-ce.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.