> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/op53xx/analog-output-modules/op5332-description.md).

# OP5332 Description

{% hint style="danger" %}

### Legacy product

**We no longer sell this product**. The recommended replacement card is the [**OP5330**](https://www.opal-rt.com/docs/op53xx/analog-output-modules/op5330-description.md). For any questions, please contact your **OPAL-RT sales representative**.
{% endhint %}

<figure><img src="https://2047776775-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgkXB7sd4eT4qhErY15uu%2Fuploads%2FbDdeTPgy0qXJc72rP0I9%2FOP5332_board.jpg?alt=media&amp;token=433f482d-46be-4494-87af-0df7c4e64dcb" alt="" width="563"><figcaption></figcaption></figure>

The **OP5332** is a high-precision analog output module designed for OPAL-RT simulators and expansion units. It offers multiple single-ended channels with simultaneous sampling, ensuring accurate and synchronized signal generation across all outputs. The specified voltage range applies uniformly to all channels.

For compatibility information, refer to the [Hardware Platforms Compatibility](https://www.opal-rt.com/docs/op53xx/overview/hardware-platforms-compatibility.md) table.

## Key features

* 8 pairs of isolated analog output channels (16 channels total)
* 16-bit resolution
* Simultaneous sampling at 2 MSPS
* Voltage range: ±16 V
* Maximum current per channel: 10 mA
* Factory-calibrated&#x20;

## Channel architecture

* Each channel of the OP5332 module uses a dedicated 16-bit resolution digital-to-analog converter.
* All outputs are sampled simultaneously at 2 MSPS, giving a total throughput of 32 MSPS.
* The channels are isolated by pair.

## Typical use case

The OP5332 is typically used to deliver analog signals to **ECUs or external devices** during HIL simulations:

* Analog outputs (up to 10 mA) feed into the ECU under test.
* The maximum current rating of the signal is 10 mA.

<figure><img src="https://2047776775-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FgkXB7sd4eT4qhErY15uu%2Fuploads%2F3GneAEP4aTXaOihtPWSS%2FOP5332.png?alt=media&amp;token=6505b91d-c0ec-43e1-9c70-f95085e7b302" alt="OP5332 typical uses cases"><figcaption></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/op53xx/analog-output-modules/op5332-description.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.