> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/pe-add-on-opal-rt/model-in-schematic-editor/configure-the-ehs-circuit-interfaces/configure-measurement-outputs.md).

# Configure Measurement Outputs

## Measure circuit voltages and currents

To measure voltages and currents within the **circuit model**, add the appropriate meter blocks. From the **Library Browser > Meters**, drag a:

* **Voltmeter** block to measure the voltage between two circuit nodes

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2Frvu5ikRna1C5pnmgRd8r%2FmeasuringCurrentAndVoltage.gif?alt=media&amp;token=7c0103e4-1326-4c31-9ad9-ba8ef6f36e2f" alt=""><figcaption></figcaption></figure>

* **Voltmeter Node** block to measure the voltage relative to a named circuit node defined with an **Electrical Node** block

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2FDw2sF6pRKjOq28rTtgMB%2FmeasuringCurrentAndVoltage3.gif?alt=media&amp;token=a016b0ec-b18a-4142-b3aa-2afcdbd70957" alt=""><figcaption></figcaption></figure>

* **Ammeter** block to measure the current flowing through a circuit branch and must be connected in series

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2FIZ3F02qOzc85A15Kito0%2FmeasuringCurrentAndVoltage2.gif?alt=media&amp;token=ecd32158-3538-4257-9b8a-4dbe01f19150" alt=""><figcaption></figcaption></figure>

## Interface meter blocks <a href="#heading-title-text" id="heading-title-text"></a>

**Meter** blocks provide the measurement outputs to <code class="expression">space.vars.cpu\_model\_veristand</code> by default. **Depending on the selected firmware**, the measurment **outputs** can be routed to:

* Veristand
* Physical analog output channels
* Waveform channels
* A combination of all these interfaces

To select the output(s):

1. Click the parameter to open the **Deep Panel**. By default, the parameter value is routed to Veristand.
2. Click the **+** icon below **DESTINATIONS** to reveal the additional options. Select **AO (Analog Output)** or **WF (Waveform Output)** to add the destination.

{% columns %}
{% column valign="middle" %}

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2FoyY6Nb26snjKzoPIykWh%2Fimage.png?alt=media&amp;token=7b08f5bf-af2d-43c9-8125-c524a0b376fa" alt="" width="405"><figcaption></figcaption></figure>
{% endcolumn %}

{% column %}

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2F63CNbu8V5sqfjn5VZMCU%2Fimage.png?alt=media&amp;token=e03646c5-c313-4a5c-8cf9-35a8954859af" alt=""><figcaption></figcaption></figure>
{% endcolumn %}
{% endcolumns %}

3. Multiple destinations can be configured and active at the same time. To remove a destination, hover over it and click the **trash** icon that appears.
4. Configure the destination using its available parameters. For **AO (Analog Output)**, select the I/O connector and channel (**Pin**) that will output the measurement. You can also configure a **Gain**, **Offset**, and **Min/Max** thresholds. For **WF (Waveform Output)**, select the waveform channel (**Pin**) to output the measurement to.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/pe-add-on-opal-rt/model-in-schematic-editor/configure-the-ehs-circuit-interfaces/configure-measurement-outputs.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.